-
product
PXI/PXIe RF Matrix, 16x2, 100 MHz, 75 Ω SMB
42-728A-101
The 40-728A-101 (PXI) and 42-728A-101 (PXIe) are 16x2 75 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
product
RF Attenuators
Amphenol RF offers a growing Attenuator product line to meet your attenuation needs. Amphenol RF attenuators are designed to offer flat attenuation over the designated frequency range and feature a microwave grade resistor that consistently reduces power. Hex flats on the body allow this attenuator to be easily torqued to the mating connector.
-
product
L-Band RF Tuner and 4-Channel 200 MHz A/D with Virtex-6 FPGA - 6U VPX
Model 58690
- Two L-Band tuners accept RF signals from 925 MHz to 2175 MHz- Two programmable LNAs boost LNB (low-noise block) antenna signal levels with up to 60 dB gain- Two programmable analog downconverters provide I + Q baseband signals with bandwidths ranging from 4 to 40 MHz- Four 200 MHz 16-bit A/Ds- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Up to 4 GB of DDR3 SDRAM; or: 64 MB of QDRII+ SRAM- PCI Express (Gen. 1 & 2) interface up to x8- Clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
Magnetic Field and Permeability Measurement
MAGNETOSCOP® 1.070
Foerster Instruments, Incorporated
The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
product
Peak/Average Reading Broadband, Multirange Directional RF Wattmeter
83060
Similar in appearance and operation to our standard Model 81060 Wattmeter, the Model 83060 converts from Average Reading to Peak Reading, with the flip of a switch, by inserting a peak reading amplifier between the element and the meter
-
product
Single 8 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-763A-001
The 40-763A-001 terminated single 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Near Field Probe Set
RF100
The RF100 probe set consists of a passive E field probe and H field probe, BNC adaptor and carry case. The output is via a BNC socket. These are general purpose probes which are ideal for use in conjunction with an EMC measuring system. They are sensitive to sources in close proximity, but are insensitive to background signals. This makes them ideal for the identification of emission frequencies in noisy environments... thus making measurements easier and quicker. The proximity requirement also enables sources to be located and the exit route identified.
-
product
RF Shield Box
Qosmotec Software Solutions GmbH
Qosmotec RF Guard is a RF shield box that allows engineers to create an affordable automated end-to-end test environment with each UE shielded individually. It enables the user to perform wireless network tests without undesired RF interference by protecting mobile devices from outside network frequencies.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Field Portable NIR Spectrometers For Mineral Identification And Analysis In Mining Exploration
With Spectral Evolution field portable NIR spectrometers and EZ-ID mineral identification software, geologists can measure and identify minerals within seconds and cover more ground than by using traditional methods. They can identify different mineral phases, create mineral alteration maps and more accurately identify mineral pathfinders for vectoring to ore deposits. Spectral Evolution's field portable, battery-operated oreXpress, oreXplorer and oreXpert ultra-high resolution NIR spectrometers are designed for mineral identification in mining exploration. The oreXpress, oreXplorer and oreXpert provide quick payback with faster, more accurate mineral identification in exploration for gold, silver, diamonds, iron, nickel, copper, uranium, aluminum - in the field, core shack, or in the lab, and provide:
-
product
PXI Dual 4 to 1 RF Multiplexer 2GHz 75 Ohm SMZ/Type 43
40-746-711
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
product
RF POWER AMPLIFIERS
BSA Series
RF Input: N-f, standard on rear panelRF Output: standard on rear panel<1 kW N-f<3 kW 7-16-f<5 kW EIA 1 5/8Mains Supply: Line Power:<1000 VA 100 ... 240 V AC ±10% / 47 ... 63 Hz1000 ... 3000 VA 200 ... 240 V AC ±10% / 47 ... 63 Hz>3000 VA 3x 400 V AC ±10% / 47 ... 63 HzElapsed Time Meter: via status displayAmbient Temperature: 0 ... +45 °CStorage Temperature: -20 ... +85 °CRelative Humidity: up to 95% (non-condensing)Operating Altitude: up to 2000 m above sea levelVibration and Shock: MIL-STD-810 GCooling: forced air with integral blowerair intake from front, air exhaust at rear
-
product
Flexible Magnetic Field Probes
Projekt Elektronik Mess- und Regelungstechnik GmbH
The active probes are equipped with active amplifier electronics and have an extremely low-impedance output, ie they can also drive long lines. The output signal is calibrated according to specification. They can not only be connected to a certain type of teslameter, but can also be connected to any signal input.
-
product
PXI/PXIe RF Matrix, Dual 2x2, 2.5GHz, 50Ω, SMB
42-877A-002
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
RF Power Meters
Peak Power Analyzer has been totally redesigned from the inside out. This meter is taking performance to a new peak and changing the way the industry views and analyzes RF data.
-
product
Portable Water Testing Field Kits
Aquagenx portable water testing field kits combine our Compartment Bag Test (CBT) E. coli Kit with key chemical and geophysical water quality parameters and testing equipment. Each field kit contains equipment and consumables for 100 samples.
-
product
CXG RF Vector Signal Generator, 9 kHz to 6 GHz
N5166B
Essential signal generation for IoT and general-purpose devices.
-
product
Standard RF Power Sensors
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
product
PXI Dual 4 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-882-002
This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
product
Complete Overview Of Magnetic Field Measuring Devices Teslameter Gaussmeter
The field strength measuring instruments are ideally suited for measuring magnetic field strength but also for residual magnetism (remanece)andetermination after demagnetization of metals.
-
product
Single 32 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-767A-001
The terminated single 32 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
PXI-2547, 2.7 GHz, 50 Ω, 8x1 PXI RF Multiplexer Switch Module
778572-47
2.7 GHz, 50 Ω, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2547 is an RF signal multiplexer switch module. The higher channel count of the PXI‑2547 makes it ideal for test systems that require the switching of a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
2 X 1 RF Switch
MX 1×2 RF
Auto detect 2×1 RF switch, used for simple automated switching or redundancy of the RF signal path.
-
product
PXI/PXIe RF Multiplexer, Dual 8-Channel, 3GHz, 75Ω, SMB
40-834A-002
The 40-834A-002 (PXI) and 42-834A-002 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXIe-5654, 250 kHz to 20 GHz, PXI RF Analog Signal Generator
784776-02
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.
-
product
Near Field Micro Probes ICR HH H Field
The measuring coil is horizontally located in the probe head. The near field micro probes are operated with a positioning system (Langer Scanner).
-
product
PXIe-2542, 6.6 GHz, 50 Ω, Solid-State, Quad 2x1 PXI RF Relay Module
780587-42
PXIe, 6.6 GHz, 50 Ω, Solid-State, Quad 2x1 PXI RF Relay Module - The PXIe‑2542 is a terminated switch module suited for routing RF signals for production test applications. It features high-performance solid-state relays that offer unique benefits such as unlimited mechanical lifetime and fast switching time. Front-mounted SMA connectors provide easy connection to your RF devices, and the module features termination on every COM line and channel. The channel termination and COM lines help minimize reflections of the RF signal and protect your instruments.





























