-
Product
1 Mm Calibration Kit
85059B
-
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
-
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
-
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
-
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Acoustic Calibrator
CAL150
-
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Sound Level Meters and Calibration
-
PeakTech Prüf- und Messtechnik GmbH
This digital sound level meter is designed for noise projects, quality control and all kinds of measurements of ambient sound, as well as for sound measurement in factories, schools, offices, in traffic , Household and much more used.
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
-
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
-
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
-
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Economy Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052D
-
The Keysight 85052D economy mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection. Connector gauges may be ordered separately.
-
Product
Linear/Angular Measurement Kit
55281B
-
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
-
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
-
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-01
-
The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form … factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
-
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
-
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
-
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Calibration
-
ION Science recommends that your instruments are recalibrated on an annual basis to ensure they continue to provide you with accurate, reliable results and that they maintain their extended warranty. Choose the right calibration solution from our range below.
-
Product
Sound Impact Sensor
29132
-
The Sound Impact Sensor detects sound from up to 3 meters away. This human input device lends noise-activation possibilities to your microcontroller projects.
-
Product
Sound and Velocity Data
MIDAS SVX2
-
The MIDAS SVX2 is the standard for the offshore Oil & Gas industry. Recognising the conflict faced by users requiring the superior Sound Velocity data from an SVP, but still needing the Salinity and Density data from a CTD, the Midas SVX2 combines both technologies to give the best of both worlds





























