-
product
PXI/PXIe MIL-STD-1553 Multiplexer, Single 8-Channel, 2-Pole
40-739-003
The 40-739-003 (PXI) and 42-739-003 (PXIe) are single 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
product
PXI/PXIe RF Multiplexer, Quad 4-Channel, Terminated, 8GHz, 50Ω, SMA
40-882B-004
The 40-882B-004 (PXI) and 42-882B-004 are quad 50Ω 4 to 1 RF multiplexers with 8GHz bandwidth.The 40/42-882B range has automatic termination of unused signals and is available as a single MUX in one slot, a dual MUX in two slots, or triple and quad MUXs in three slots.
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
40-514-101
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
PXI RF Multiplexer, 4x SP4T, 1.3 GHz 75 Ω, SMB Connectors
40-755-304
The 40-755-304 is a 5xSP4T 75 Ω multiplexer and is part of a range of high density RF multiplexers available in 50 Ω and 75 Ω variants with up to 10xSP4T switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot.
-
product
LXI Microwave Multiplexer, SP6T, 10-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-710
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
product
PXI RF Multiplexer, 10x SP4T, 1.3 GHz 75 Ω, Multiway Connectors
40-755-210
The 40-755-210 is a 10xSP4T 75 Ω multiplexer and is part of a range of high density RF multiplexers available in 50 Ω and 75 Ω variants with up to 10xSP4T switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot. The connectors used are fully supported by the range of Pickering Interfaces connection solutions.
-
product
PXI 2A Multiplexer, 1-Bank, 4-Channel 32-Pole
40-614-020
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI 4 Banks of 20 Channel 2 Pole MUX
40-615-022-4/20/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
LXI Microwave Multiplexer, SP6T, 4-Bank, 18GHz, 50Ω, SMA
60-800-104
Our 60-800-104 is a 4 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 50Ω, MCX
42-875A-101
The 40-875A-101 (PXI) and 42-875A-101 (PXIe) are single 50 Ohm 16-channel RF multiplexers in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
PXI Very High Density Mux Dual 10 Ch 8 Pole
40-670A-022-D/10/8
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-018-M62.5
The 40/42-852A-018-M62.5 is a PXI/PXIe 8-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI MUX 4 Bank, 16 Channel Screened 1 Pole
40-610-021-S-4/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI 4 Banks of 20 Channel 1 Pole MUX
40-615-021-4/20/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
LXI Microwave Multiplexer, SP6T, 4-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-504
Our 60-800-504 is a 4 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI 5A Mux 4-Bank 11-Ch Isolated COM
40-651-013
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI High Density MUX BRIC, 3-Chan, 160-Pole
40-570-013
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-421-T
The 40-785C-421-T (PXI) and 42-785C-421-T (PXIe) are single failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXIe Microwave Multiplexer, Single SP8T, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-041-E
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
product
PXI 16-Channel USB Data Comms MUX
40-737-001
The 40-737-001 is a 16:1 USB data communications multiplexer suitable for switching USB1 and USB2 data and power connections using a 78 way D-Type connector. The data signal paths are 2-pole arranged as differential pairs as defined by the USB standard.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-214-M50
The 40/42-850A-214-M50 is a PXI/PXIe 4-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67 GHz, 50 Ω, SMA-1.85, Terminated, Failsafe
40-785C-572-T
The 40-785C-572-T (PXI) and 42-785C-572-T (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers a single slot.
-
product
PXIe-2747, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module
780587-47
PXIe, 2.7 GHz, Dual 8x1 PXI RF Multiplexer Switch Module—The PXIe‑2747 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 2.7 GHz in production test applications. The high channel count of the PXIe‑2747 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.
-
product
PXI 8-slot BRIC Multiplexer, 96-Channel, 10-Pole (8 Sub-cards)
40-570A-416
The 40-570A-416 is a 96-channel, 10-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXI High Density Multiplexer, 4-Bank, 20-Channel, 1-Pole
40-615A-016
The 40-615A-016 is a 4-bank, 20-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe High Density 2A Multiplexer, 26-Bank, 4-Channel, 1-Pole
40-614D-023
The 40-614D-023 (PXI) and 42-614D-023 (PXIe) 26-bank, 4-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI High Density Multiplexer, 1-Bank, 80-Channel, 2-Pole
40-615A-012
The 40-615A-012 is a 1-bank, 80-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
product
PXI Power & Sense Multiplexer, 2-Pole, 18-Channel
40-658A-002
The 40-658-002 is a PXI multiplexer combining a 2-pole 18-way power distribution MUX with a second lower power 2-pole 18-way MUX in a convenient single slot PXI module. It is ideal for power distribution where power and sense signals are required to be connected to an array of devices under test.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber, FC/PC Connectors, With Interlock
42-852A-118-HI
The 40/42-852A-118-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.





























