product
PXI 8-slot BRIC Power Multiplexer, 48-Channel, 6-Pole (8 Sub-cards)
40-571A-406
The 40-571A-406 is a 48-channel, 6-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-518-M62.5-HI
The 40/42-852A-518-M62.5-HI is a PXI/PXIe 8-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, MCX
42-832A-102
The 40-832A-102 (PXI) and 42-832A-102 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI/PXIe High Voltage Multiplexer, Quad 5-Channel, 2-Pole
40-321-121-HI
The 40-321-121-HI (PXI) and 42-321-121-HI (PXIe) are quad 5-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 12-Bank 26.5GHz SMA
60-801-312
The 60-801-312 is a 6-channel, 12-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI 1 Bank of 80 Channel 2 Pole MUX
40-615-022-1/80/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, SC/PC Connectors, With Interlock
42-850A-214-M62.5-HI
The 40/42-850A-214-M62.5-HI is a PXI/PXIe 4-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 50Ω, MCX
40-872A-101
The 40-872A-101 (PXI) and 42-872A-101 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40/42-872A has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18GHz, 50Ω, SMA, Remote Mount
40-785C-523-E
The 40-785C-523-E (PXI) and 42-785C-523-E (PXIe) are triple SP6T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI High Density Mux 49 Channel 2 Pole
40-670A-021-49/2
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
product
PXI 2A Multiplexer, 2-Bank, 16-Channel, 4-Pole
40-614C-012
This 2-bank, 16-channel, 4 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI Very High Density Multiplexer, 198-Channel, 1-pole
40-670C-022-198/1
The 40-670C-022-198/1 is a 198-channel, 1-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 40 GHz, 50 Ω, SMA, Terminated, Remote Mount
40-788-052-TE
The 40-788-052-TE (PXI) and 42-788-052-TE (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays.
-
product
LXI Microwave Multiplexer, SP6T, 2-Bank, 18GHz, 50Ω, SMA
60-800-102
Our 60-800-102 is a 2 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI Solid State MUX, 1 bank, 160 channel
40-680-006
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 26.5GHz, 50Ω, SMA
40-784B-033
The 40-784B-033 (PXI) and 42-784B-033 (PXIe) are triple SP6T 26.5GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 1-Bank 18GHz SMA
60-801-201
The 60-801-201 is a 6-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40GHz, 50Ω, SMA-2.9, Terminated
40-785C-441-T
The 40-785C-441-T (PXI) and 42-785C-441-T (PXIe) are single SP4T 40GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe High Density 2A Multiplexer, 4-Bank, 32-Channel, 1-Pole
40-614D-006
The 40-614D-006 (PXI) and 42-614D-006 (PXIe) 4-bank, 32-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 16-Channel, 1-Pole
40-614D-003
The 40-614D-003 (PXI) and 42-614D-003 (PXIe) 8-bank, 16-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI 5A MUX, 1-Bank, 48-Chan, Ind. Isolation
40-651-101
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 26.5GHz, 50Ω, SMA, Remote Mount
40-784B-033-E
The 40-784B-033-E (PXI) and 42-784B-033-E (PXIe) are triple SP6T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
LXI Microwave Multiplexer, SP4T, 5-Bank, 26.5GHz, 50Ω, SMA
60-803-305
Our 60-803-305 is a 5 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 11-Bank 18GHz SMA
60-802-211
The 60-802-211 is a 4-channel, 11-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 8 GHz, 50 Ω, N-Type, Failsafe
42-788-011
The 40-788-011 (PXI) and 42-788-011 (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
PXI Dual 8 to 1 RF Multiplexer 3GHz 50 Ohm SMB
40-874-002
The 40-874-002 is a 50 Ohm 8 to 1 RF multiplexer with 2 banks in a single PXI slot. It has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of this RF multiplexer has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI High Voltage Multiplexer, 12-Channel
40-320A-001
The 40-320A-001 is a single 12-channel MUX and is part of our 40-310/320A range of High Voltage Switching Modules which will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320A) configurations.
-
product
PXI 10A Power Multiplexer, 1-Bank, 32-Channel
40-661A-004
The 40-661A-004 is a single pole, 1-bank, 32-channel PXI power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
product
PXI 3A Power MUX BRIC, 16-Channel, 6-Pole
40-571-402
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI Microwave Multiplexer, Dual SP4T, 26.5GHz, 50Ω, SMA
40-785C-432
The 40-785C-432 (PXI) and 42-785C-432 (PXIe) are dual SP4T 26.5GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.