Microwave Leakage
safety check to assure free from leaks.
-
Product
LXI Microwave Multiplexer, SP6T, 4-Bank, 67GHz, 50Ω, SMA-1.85
60-800-804
-
Our 60-800-804 is a 4 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Leakage Clamp Meters
-
Precision Mastech Enterprises Co.
Specialized, high-sensitivity electrical testing tools designed to measure low-level AC current (typically in milliamps, to detect ground faults, insulation failures, and potential hazards without disconnecting equipment
-
Product
PXIe Flexible Microwave Module, Dual SP6T 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-005
-
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
Product
Cabin Leakage Tester
-
The Kanomax Cabin Leakage Tester pressurizes or depressurizes the automobile vehicle cabin to measure the changes in cabin pressure. The control unit consists of a manometer and pressure transducers. The manometer detects the leakage flow, which is calculated by measuring the nozzle pressure relative to static pressure. The tester controls an adjustable fan to maintain static test pressure.
-
Product
Leakage Current Tester
-
Premier's Leakage Current Tester (also known as Hipot Tester) simulates the effect of a person touching exposed metal parts of a product and detects whether or not the leakage current that would flow through the person's body remains below a safe level.
-
Product
LXI Microwave Multiplexer, SP6T, 9-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-509
-
Our 60-800-509 is a 9 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Medical Leakage Tester
GLP2-CE
-
For testing the leakage current of medical equipment to standards EN 60990 + EN 60601.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-310-011
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Leakage Current Tester
2675
-
Shenzhen Chuangxin Instruments Co., Ltd.
RK2675 series Leakage Current Tester is used to measure the electrical insulation quality and products’ safety performance of the main indicators.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 67GHz, 50Ω, SMA-1.85
60-800-805
-
Our 60-800-805 is a 5 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Earth Leakage
-
Earth leakage is when the current flowing in a system finds an alternative return path other than active and neutral conductors.
-
Product
Medical Leakage Current Tester
2675Y
-
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
Product
PXIe Flexible Microwave Module, Dual SP4T Terminated 40 GHz, Single SPDT 40 GHz, 50 Ω, SMA
42-890-002
-
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
Product
PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-785C-531
-
The 40-785C-531 (PXI) and 42-785C-531 (PXIe) are single failsafe SP6T 26.5 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, SP6T, 15-Bank, 50GHz, 50Ω, SMA-2.4
60-800-615
-
Our 60-800-615 is a 15 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
AC Leakage Current Tester
229-2
-
Testing for dangerous small leakage currents is easy with the Simpson Model 229-2 Leakage Current Tester. For use in appliance field service, in the lab, or in production, the 229-2 approximates the human threshold of perception in detecting hazardous AC leakage current. The 229-2 comes with test leads with alligator clips, manual and batteries.
-
Product
PXI Microwave Relay, Dual SPDT, 26.5GHz, 50Ω, SMA, External Termination
40-781A-322
-
The 40-781A-322 (PXI) and 42-781A-3221 (PXIe) are dual SPDT 26.5GHz microwave relay modules with external terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50GHz in 50Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 15-Bank 26.5GHz SMA
60-801-315
-
The 60-801-315 is a 6-channel, 15-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI Microwave Multiplexer, Single SP6T, 26.5GHz, 50Ω, SMA
40-784B-031
-
The 40-784B-031 (PXI) and 42-784B-031 (PXIe) are single SP6T 26.5GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
Line Leakage Tester
LineCHECK II
-
Designed for Automated Test ApplicationsFull Compliment of Automation InterfacesComplete Line Leakage Testing SolutionEnhanced Graphic LCDCompatible with Scanning Matrix for Patient Lead TestingContinuous Run FeatureSoftware CompatibleSafety Agency Listed
-
Product
SP4T Microwave Switch Plug-In
1260-164AH/BH
-
The Astronics 1260-164AH/BH is a 2-slot microwave switch plug-in available in two standard configurations with either one or two relays, each being SP4T, 1-pole, 4-throw.
-
Product
LXI Microwave Multiplexer, SP6T, 4-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-504
-
Our 60-800-504 is a 4 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI Microwave Multiplexer, Dual SP6T, 26.5GHz, 50Ω, SMA
40-785C-532
-
The 40-785C-532 (PXI) and 42-785C-532 (PXIe) are dual SP6T 26.5GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
SF6 Leakage Detector
GDWG-IV
-
GDWG-IV SF6 Gas Leak Detector is infrared type leak detector. It is color LCD display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It's a good device suitable for power supply department, installation and overhaul unit, power test institute.
-
Product
FieldFox C Handheld Microwave Analyzer, 6.5 GHz
N9914C
-
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth. Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
Product
FA Leakage Switch Mainframe
B2200A
-
The B2200A reduces the cost of test by enabling characterization tests to be automated, without compromising the measurement performance of the semiconductor parameter analyzer. It supports a 4-SMU, full-Kelvin configuration and a capacitance meter, with room for future expansion. Includes 14 inputs, each with a unique internal measurement path, and a distinctive capacitance measurement compensation feature for two of the inputs. Provides front panel control via keypad or optional light pen, and supports instruments such as pulse generators.
-
Product
LXI Microwave Multiplexer, SP6T, 7-Bank, 18GHz, 50Ω, SMA
60-800-107
-
Our 60-800-107 is a 7 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Leakage Current Alarm Signaler
MPU-1
-
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.
-
Product
DC Earth Leakage Current Measurement
DCZCT-11M
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC Earth Leakage Current Measurement *Bipolar DC ±12V Power Supply*Output DC ±1.5V at DC 10mA *Isolated Housing Case based on UL94V-0*Through Hole PCB Mount Type, Exciting Current Method
-
Product
Microwave Probes
D-Probe
-