Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
SCB-100A Noise Rejecting, Shielded I/O Connector Block
785024-01
Terminal Block
100-Pin Female SCSI to 100-Pin Female Screw Terminal, DIN Rail, Wall, Pane Terminal. Block The SCB-100A is a shielded I/O connector block for interfacing I/O signals to NI data acquisition devices with 100-pin connectors. Combined with shielded cables, the SCB-100A provides rugged and protected signal connectivity. It has a mechanical enclosure that features a magnetic removable lid and pinout diagrams. It also includes pane, wall, and DIN Rail mount options.
-
Product
Explosion-Proof Transducer
HX
-
Computer Conversions Corporation
Computer Conversions Explosion-Proof Transducer Housings are designed to operate in hazardous environments requiring an Explosion-Proof Enclosure. Suited with internal (Factory Installed) resolver-transducers; these units can be provided as part of an absolute and/or incremental encoder system. Most transducer cables only require six conductors, shielding is optional, and systems are capable of maintaining 1000' cable runs in severe RFI environments.
-
Product
PCI 32xSPST Shielded Reed Relay Card
50-125-021
Reed Relay
The 50-110/115 range of PCI shielded switching cards are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 200 pin female connector.
-
Product
68-Pin VHDCI Male to 68-Pin VHDCI Male, 100 Ω, Double-Shielded LVDS Cable
188143-01
LVDS Cable
SHC68-C68-D3, Male VHDCI to Male VHDCI, Shielded LVDS Cable, 1 m
-
Product
68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable
156166-01
High Speed Digital Cable
The SHC68-C68-RDIO2 is designed and shielded specifically for the digital I/O connector on the USB-7855 and USB-7856 Multifunction Reconfigurable I/O Devices. This cable features digital I/O lines individually twisted with digital ground for high-signal integrity and noise immunity. The SHC68-C68-RDIO2 is available in 1 m and 2 m lengths.
-
Product
Dual RF Shielded Test Enclosure
JRE 0814-2R
-
Containing all the capability of the larger JRE enclosures, the rack mounted 0814-2R is ideal for testing devices with a tall form factor. Two independent 0814 series enclosures are mounted in one 19 inch rack. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
Product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
-
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
Product
Standard VXI Module Shield Kits With Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Signal, Patchcord, ITA, 36", QuadraPaddle, 24AWG Single Conductor Shielded, Single Ended
7-121974000-036
Signal Patchcord
Signal, Patchcord, ITA, 36", QuadraPaddle, 24AWG Single Conductor Shielded, Single Ended.
-
Product
MMIHF-A-DO-1, MMIHF-A-DO-1 - Shielded Tandem Test Fixture
100229
-
MMIHF-A-DO-1 - shielded tandem test fixture with single mechanics for high frequency and radio applications. Protection of the environment from the DUT or shielding of interferences on the test. With our high-frequency fixture you can test sensitive and transmitting assemblies - even those with a combination of transmitter and receiver - in detail without risking consequences for your production.
-
Product
Lightning "Emulator" Shield
SEN-39002
-
Arduino shield, ideal for AS3935 lightning sensor development. The lightning "emulator" generates a RF signal that mimics lightning strikes. This board is in an Arduino Uno form factor, and only uses GPIO and I2C, so can be stacked on many form factors (developed on an Uno and Mega).
-
Product
VXI C-Size Blank Board
115250
-
* C-Size blank PC Board for mounting devices, modules or circuits.* Includes VXIbus P1 and P2 connectors and decoupled power pads.* Includes pads for all VXI bus signals.* Includes pad patterns for common front panel connectors, LEDs, and a Reset Switch.* Includes CAD Design aids for Schematic Capture, PC board layout and front panel machining.* Use with ICS 1, 2 and 3-slot wide Module Shield Kits to create a complete enclosed module.* Use with ICS Front Panel Kits to add a front panel and ejectors to the blank board.
-
Product
68-Pin VHDCI Male Connector To 4 Industrial Ethernet (IXB) Female, Shielded Differential Digital I/O Cable
134727-1R6
Digital Cable
68-Pin VHDCI Male Connector To 4 Industrial Ethernet (IXB) Female, Shielded Differential Digital I/O Cable
-
Product
42-Pin Male Nano-Pitch To 42-Pin Male Nano-Pitch, Shielded OCuLink Cable
785486-01
-
Nano-Pitch Male to Nano-Pitch Male OCuLink x4 Cable, 1 m
-
Product
Arduino CAN Shield
IFB-10003-AWP
-
CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!
-
Product
Shielded Container with GR1 CZT-Based Gamma Radiation Detector
Quant GR1
-
Quant GR1 is a gamma detector solution for mobile laboratory radionuclide analysis. It is designed for measuring the activity of radionuclides in filters, filter papers, beakers of samples. It comes with an optimised and integrated lead/copper shield that enables operation in both standard and raised backgrounds.
-
Product
Interface Technology Style VXI Module Shield Kits
-
*Encloses Interface Technology style, slotted-edge, C-size PC boards All kits include side shields, a pre-machined blank front panel, ejector handles, all necessary hardware and assembly instructions. * All kits are available with customized front panels and side shields.
-
Product
General Purpose Switches
SMX-5XXX (General Purpose)
General Purpose Switch
The VTI SMX-5xxx Series of general purpose switches deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Embedded virtual schematic control simplifies setup and debugging, allowing all relays to be engaged independent of application software and device drivers.Ideally suited for a wide range of discrete signal switching, the SMX-5xxx Series provides uncompromised measurement integrity ideal for the most demanding aerospace, defense and automotive automated test equipment (ATE) applications.
-
Product
Compact EMS/EMI Test Platform
CEMS100
Test Platform
Setting up an EMS/EMI test system is a very complex process requiring significant investment. The steps involved include custom planning, design, installation and configuration of various components and standalone instruments as well as the RF shielded anechoic chamber. Rohde & Schwarz offers the standardized R&S®CEMS100 test platform that is the company's first flexible, reliable and cost-effective off-the-shelf solution for radiated EMS measurements in line with IEC/EN 61000-4-3.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Rack Mount Power Supplies
AC-DC High Voltage Power Supplies
-
Ideal for laboratory and instrumentation applications, these rack mounting supplies have the same output ratings and specifications as the modular supplies, but additionally feature calibrated ten-turn controls (with locking vernier dials) for precisely setting voltage and current. Voltmeter and ammeter are standard. An 8' long shielded output cable is included.
-
Product
Test Fixture, Shielding Effectiveness
EM-2108 | 1.5 GHz – 10 GHz
-
The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Comb Generator
CG118
-
The main application of comb generator is to quickly verify 1GHz above radiated emission and conducted emission test setup.And the most important application is 3m chamber and 10m chamber 1GHz above to18GHz with 250MHz frequency spacing for site validation,shielding efficiency. reference signal source Noise Generators Signal Generators
-
Product
Forensic Type
-
Concentric Technology Solutions, Inc.
Forensic Type Shielded Enclosures are designed specifically for forensics application and features forensics tamper-proof hardware and a built-in padlockable latch to prohibit unauthorized access inside the shield box and to maintain the chain of custody for the devices collected. Devices collected within a smaller forensics shield boxes on site can be easily transferred into a larger forensics enclosure for full forensics evaluation and interrogation.
-
Product
Coax, Patchcord, Receiver, 72", Micro Coax, RG316 Double Shield Tan, SMA Plug
7-368117635-072
Coax Patchcord
Coax, Patchcord, Receiver, 72", Micro Coax, RG316 Double Shield Tan, SMA Plug.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
68-Pin D-SUB Female to 68-Pin D-SUB Female, Twisted Pair, Shielded Multifunction Cable
199006-0R5
Multifunction Cable
SH68-68-EPM Shielded Cable, 68 D-Type to 68 D-Type, 0.5M