IR Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
-
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Laser Calibration System, Superior Accuracy, Portability and Reliability
5530
-
The configurable system offers all the components you need to perform a variety of measurements using the USB on your PC as the host controller and power source. For basic linear measurements you will need the USB Axis Module, USB Sensor Hub, Air and Material Sensors, Sensor Cables, Software, Laser, Laser Cable, Remote Control (optional)and the Linear Optics Set. Other available options include the Laser Tripod (with laser mounting plate), optics and fixturing kits for making additional types of measurements, and wheeled transit cases.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S97553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
IR Digital Laser Thermometer
214L
-
With a user switchable measuring range of -35°C to 365°C or -31°F to 689°F, a digital display of the temperature is produced in less than one second.Non-contact technology with laser spot indicatorºC / ºF user switchableFast, 1 second scanning of any surfaceMeasure objects as small as 25mm (1”)Distance-to-Target Ratio of 8:1Easy to read LCD display
-
Product
Sound Level Meters & Calibrators
-
A sound level meter, also known as sound pressure level (SPL), decibel (DB) meter, noise meter or noise dosimeter is mainly used for measuring sounds travelling through air. It is used to test noise or sound levels by evaluating sound pressure. It uses a microphone to capture sound and the sound is then evaluated in the device. It is commonly used to prevent loud noises to create a better work environment.
-
Product
Light / Lux Meter, Calibrated w/D & U, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL DU
-
The 72-7250 CAL DU from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)
CK058M
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Calibration Light Source
CAL1
-
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
Product
Electrical Calibration
-
We offer electrical calibration on a wide range of instruments covering all brands and types of electrical testers. Being the only calibration company in Ireland to have Fluke's state of the art 5320a Multi-product calibrators allows us to match or in many cases exceed the manufactures calibration such as Fluke, Megger, Kewtech etc, but for a lot less cost and downtime to you.
-
Product
Horizontal Calibration Instruments (Lab)
Labconcept Nano
-
The Labconcept Nano is a new reference in the field of dimensional metrology. It integrates 40 years of knowledge and continuous improvement. It is a remarkable instrument for all measuring tasks that require extremely high accuracy.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Chemical Calibration
-
Trescal provides full Chemical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Chemical Calibration services can be delivered at your site or at our lab. Accreditations for our chemical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
Product
Speedometer Calibrator
-
Hypertech’s Speedometer Calibrator can correct the speedometer and odometer for tires up to 54 inches (depending on the application), and/or non-stock rear gear ratios. This new device is engineered for consumers that want the speedometer recalibration functions of the Speedometer Calibrator without the additional expense of the other tuning features. The Speedometer Calibrator comes with a USB cable and a CD containing software to enable quick updates and upgrades over the internet. For an additional charge, the Speedometer Calibrator can be upgraded to a Speedometer Calibrator via the internet to include all the Speedometer Calibrator features available for that vehicle.
-
Product
Light / Lux Meter, Calibrated w/Data, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL D
-
The 72-7250 CAL D from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Fixed Gas Find IR Camera
FLIR GF77a
-
The FLIR GF77a is the first uncooled autonomous leak detection camera from FLIR designed specifically to visualize methane gas. This affordable, fixed-camera solution provides upstream and midstream gas processors, producers, or operators the features they need to continuously monitor for potentially dangerous, invisible methane leaks. Small and lightweight, the FLIR GF77a is packed with FLIR-patented features, such as High Sensitivity Mode (HSM), for improved gas visualization. The GF77a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices.
-
Product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL
-
The 72-7755 CAL from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
100-Amp Current Calibrator And AC/DC Transconductance Amplifier
2555A
-
World’s Leading Precision 100-Amp AC/DC Current Standard - For 30 years Valhalla Scientific’s design has proven rock-solid reliability in metrology labs worldwide. The 2555A is a calibration powerhouse with wide-ranging applications and unsurpassed quality.
-
Product
Zero Gas Generator - Calibration of Ambient Air Monitoring Systems
ZNV-7
-
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
Product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
-
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
WAVEPULSER-40IX + WAVEPULSER-SI-STUDIO-NRZ + Adaptors and Calibration Kit
WAVEPULSER-40iX-BUNDLE
-
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables, bundle.
-
Product
Temperature Calibrators
-
This temperature calibrators offering is a complete selection of everything needed to calibrate your temperature measurement equipment all in one place.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
Phase Noise Generator / Calibrator
PNG-A
-
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.





























