Kelvin Probes
Quantify changes in contact surface potential or work function difference of the Kelvin 'Junction' measuring the flow of charge from one material to another.
-
product
BIP-3 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1Z1-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72I15-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-2W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1W2S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52B-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50G
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type E, Ø1.50mm, 155gf
K100-E150155-SKAU
K100 Series, Pitch 100mil, Tip Style E, Tip Diameter Ø1.50mm, Spring force 155gf, Steel with Gold Plating.
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1P-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
High 0.75 (21.00) - 8.00 (227.00) Long Travel Bead Probe
BPLT-25F-8
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T79-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
DER-100 Double-Ended Receptacle
DER-100
Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 130Recommended Travel (mm): 3.30Overall Length (mil): 1,710Overall Length (mm): 43.43Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.71Rec. Mounting Hole Remark: 67 to 69 mil / 1.70 to 1.75 mmRecommended Drill Size: #51 or 1.75 mm
-
product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25Z1-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Off-Set Kelvin Test Sockets
This is an innovative and robust contact technology for making Kelvin contact to 0.5mm pitch QFNs. The contact uses a tip that is angled to one side, matched to an orientation that's flat on the tip. Two such contacts placed in opposition will touch the pad within 0.125mm. And because the tip is offset, the probe diameter is a robust 0.39mm and the load board pad pitch remains 0.5mm.
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1L24-10
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1J-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1W2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2J30-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Brute Hight Current Probes
P4301
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1V-10-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L36-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3E-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25I8-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High 4.00 (113.00) - 6.70 (190.00) General Purpose Probe
P2250-9-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-R
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
product
Cup, Concave 90/120°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0A
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13