Filter Results By:

Products

Applications

Manufacturers

Showing results: 7951 - 7965 of 8455 items found.

  • Temperature Forcing System

    ETF-SERIES - Envisys Technologies

    Precise Temperature Accuracies with Reliable Test Results Temperature Limits: -40/-60 °C to 30 °C Temperature Accuracies: ±2-3°C Temperature Rate of Change: 20-25 deg /min (Non-linear) Maintenance Free Access to The System Self-Sufficient System Compact with small footprints suitable for any space constraint laboratories Low decibel system Suitable for testing electronic chips / devices Environmentally friendly refrigerants Efficient heating Microprocessor based single set point PID temperature controller with data logging Flexible hose up to 2.5-3.0m Interchangeable heads according to chip size. Inbuilt electrical control panel with switchgear system

  • True RMS 600 A Solar Clamp Meter

    FLIR CM65 - Teledyne FLIR

    The CM65 clamp meter is designed for solar installation, maintenance, and troubleshooting professionals. Photovoltaic (PV) installers can trust this rugged solar clamp meter to accelerate and simplify PV panel testing at new and existing sites. The quick-connect MC4 test leads and non-invasive clamp-on current readings make DC voltage measurements on solar panel strings and inverters safer, more accurate and easier to perform. Validate AC output and inverter efficiency quickly, and monitor readings from your smartphone via a wireless METERLiNK® connection to the FLIR Tools® mobile app. These features make the FLIR CM65 the PV installer’s go-to clamp meter for faster, safer results.

  • High Voltage Pulse Attenuators

    Barth Electronics, Inc

    Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor.  These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators.  These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.

  • Dual Servo Electrical Test Fixture

    TA-334001 - Tech-Aid Products

    The TA-334001 is a Dual Servo Electrical Test Fixture made to be an equivalent substitute for the Honeywell test fixture T-334001. The test fixture front panel duplicates all the proper switch numbers and descriptions so the technician can follow by the book testing. The panel overlay text is reverse screened (backside) to insure that text quality will not degrade over time. All the appropriate test jacks are provided on the panel for servo pin and bracket breakouts. This fixture provides for the switching of motor direction, clutch, tach selection, synchro selection, limit switching and polarity relays. Panel meters are provided on the test fixture so that the technician can monitor the servomotor voltage as well as clutch voltage and current.

  • Electrical Safety Testers

    STW-9800 Series - Texio Technology Corp.

    * 200VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)

  • Electronic DC Load, 500V, 16A, 400W

    LDH400 Series - Aim-TTi

    Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option

  • EMCTD Broadband RF Safety Systems

    LBA Group, Inc

    The EMCTD analog Smart Fieldmeter® is easy to read and to operate. The EMCTD broadband electromagnetic probe covers the 0.2 to 3000 MHz spectrum where most common industrial, communications, medical and government RF emitters are found. The ANGPE-3000  system enables checking of home, office, and workplace RF levels. The system is designed to conveniently measure RF levels around WiFi access points, RFID systems and rooftop antennas; to find transmitter cabinet radiation, locate transmission line leaks, to identify non-radiating antenna elements, and much more. With the supplied NIST-traceable calibration, this system supports laboratory testing of RF devices in compliance with present EMC and RF safety standards.

  • Design for Test Service

    Testing House, Inc.

    Design For Test (DFT) is a technique used to implement certain testability features into a product. Testing House can provide an analysis of the CAD data for testability of your circuit board. Access to a board can be very difficult as boards get smaller and designs get more densely populated. We can work with your design engineer to improve testability and maintain an effective in-circuit test. When access to the board is limited and boundary scan devices are present, we can provide the customer a list of key nodes that will require access in order to provide a very effective test. Our analysis will provide a list of all the accessible test points and an explanation for any nodes declared inaccessible.

  • Optical Power Meter

    TM233 - T&M Tools Limited Co

    TM233 Handheld OpticPower Meter(TM233-OPM ) are mainly used for continuous optical signal power measurement,Low power microprocessor is used for control,The TM233-OPM has the advantages of fully functional and reliable performance. Widely used in optical fiber construction and maintenance, optical fiber communication, optical fiber sensing, optical CATV and other fields. Instrument mould adopts advanced cold shell molding process; beautiful and durable, Instrument mould Design meets Ergonomic requirements. The TM233-OPM uses the built-in detector, which can be protected well. With a small shape, you can choose the backlight display and automatic shutdown function, with ultra wide optical power testing range.

  • 10 GHz Signal Source

    YIG Series - SignalCore, Inc.

    The SC5503B and SC5502A are designed to meet demanding low phase noise applications. This is accomplished by employing a multiple phase-locked loop architecture as well as a YIG oscillator as the heart of its synthesizer. Frequency accuracy is provided by an onboard 10 MHz temperature compensated crystal oscillator (TCXO) which can be phase locked to an external reference source if required. These modules can be used as standalone CW signal sources or as LO sources for frequency conversion systems such as the SignalCore IQ modulators and demodulators. They are designed to meet the requirements of many modern applications such as wireless device testing, software-defined radio research, point-to-point radio, multi-channel coherent systems, and other academic and military programs.

  • Light Sources

    Inframet

    There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:

  • Flightline Pilot Static Test Set

    ADTS-3350 Series - TestVonics, Inc.

    TestVonics™ ADTS-3350 Series Test Set is a portable, high precision, dual channel pitot static test system. This tester is designed to calibrate, test and troubleshoot air data instrumentation and aircraft pitot-static systems. The test set has been designed with functional and reliability features highly suited to withstand the harsh environmental and demanding conditions of the flight line environment, especially for military end users. The test set is designed for testing a wide range of commercial and military aircraft flight control systems, both rotary and fixed wing. The ADTS-3350 Series accuracy complies with standards for RVSM and is designed to replace the TTU-205 and other legacy test sets.

  • Multimedia Test Video Generator/Analyzer

    882EA-DP - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 882EA-DP test instrument with both a DisplayPort 1.1 transmitter and receiver (analyzer) option is packed with features for video and audio testing of DisplayPort monitors and sources at pixel rates up to 268 MHz. The 882EA-DP test instrument provides two (2) additional DisplayPort ports for passive monitoring of the link layer through the optional Aux Channel Analyzer (ACA) application. The ACA option enables you to monitor link training transactions either between the instruments Tx port or its Rx port with the DisplayPort device under test. The 882EA-DP instrument can optionally be equipped with industry approved compliance tests for Link Layer, EDID and HDCP 1.2.

  • Portable Leeb Hardness Tester Probes

    Beijing TIME High Technology Ltd.

    There are 7 kinds of probes to work with Leeb hardness tester for different applications, which is D / DC / D+15 / C / G / E /DL.● Universal Impact Device D - For the majority of hardness testing requirements.● DC - Used in very confined spaces, e.g. in holes, cylinders or for internal measurements on assembled machines.● DL - For measurements in extremely confined spaces or at the base of grooves.● D+15 - For measurements in grooves or recessed surface.● C - Surface hardened components, coatings, thin walled or impact sensitive components (small measuring indentation).● G - Solid heavy or rough components. e.g. heavy castings and forgings.● E - For super hard materials.

  • Penetrometers

    PCE Instruments

    Penetrometers measure the firmness or hardness of fruit. Penetrometers are ideal for determining the best time to harvest fruit or to test its progress to maturity. The firmness of fruit is one of the most widely used parameters in testing its maturity, together with measuring the fruits sugar content using refractometers. Electronic penetrometers come with different diameter penetration points. This allows for fruit of different size and hardness to be tested. It is important that this first part of the measurement process is done correctly if the readings obtained are to be valid in making adequate decisions as to when the fruit should be harvested. It is important the the samples that are measured are representative of the entire crop, considering a sufficient minimum quantity sample, size and quality.

Get Help