Filter Results By:

Products

Applications

Manufacturers

Similar Topics: POTS

POT

Measure the voltage in a circuit or function as voltage dividers.


Showing results: 16 - 19 of 19 items found.

  • Automatic Transformer Tester

    CVCT-S20 - Vasavi Electronics

    Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.

  • Hygro-Thermometer Humidity Alert with Dew Point

    Extech 445814 - Extech Instruments Corporation

    This Humidity Alert Hygro-Thermometer has a programmable %RH audible and visual alarm that alerts you when humidity exceeds the set limit. Large LCD simultaneously displays Temperature, Humidity and Dew Point. Product measures Humidity from 10 to 99% and Temperature from 14 to 140°F (-10 to 60°C). The meter has a basic accuracy of ±4%RH and ±1.8°F/1°C. Rear calibration pot for Humidity and Temperature. Featuring maximum/minimum with reset functions that store and recall the highest and lowest readings recorded. Comes complete with built-in stand, wall bracket and AAA battery.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)

    CVCT-S20 - Vasavi Electronics

    Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.

Get Help