-
Product
Tunable Lasers
-
In 1989, Santec became the world’s first manufacturer of a single mode external cavity tunable laser. Developing the technology over the years, we have optimized the lasers to have a high sweep speed, wide tuning range, narrow linewidth and low noise.
-
Product
Wavelength Meters
-
Keysight multi-wavelength meters are an essential tool for measuring DWDM signals and for calibrating and testing fixed-wavelength and tunable transmitter lasers, featuring high resolution, accuracy and repetition rate. The broadband mode extends support to high-rate modulated signals as well.
-
Product
Optical Test Platforms
-
We offer a range of complete systems for measuring optical properties by combining our tunable lasers, optical switches, polarization controller, power meter and software. Please feel free to contact us for customization according to your needs.
-
Product
Tunable Laser Source, High Power And Low SSE
N7778C
Laser Source
The N7778C value line tunable laser source offers a peak output power of more than +12 dBm, at least 75 dB/nm above its spontaneous emission level. It features a typical wavelength repeatability of ±1.5 pm at two-way sweeps up to 200 nm/s. The N7778C’s balance of features, performance and price makes it suitable for cost-effective, high-throughput manufacturing-floor component testing as well as for coherent transmission experiments.
-
Product
Optical & RF Test Equipment Repair and Calibration
-
Custom Calibration Solutions, LLC
We are the only commercial repair lab in the country capable of fixing major problems with optical test equipment including OSA's, Tunable Lasers, Attenuators and Optical Wavelength meters.
-
Product
Desktop Tunable Laser Source
UC8110
-
The UC8110 desktop tunable lasers offer superior performance for the test of DWDM components, AWG & PLC components, optical amplifiers, DWDM system and other general purpose of fiber optical test and measurement applications. It is a wavelength high accuracy, high power output, small dimension, fast startup, affordable tunable laser source system. UC INSTRUMENTS provides C band, L band, or C+L band tunable laser sources options.
-
Product
2 kHz C Band Fast Swept Tunable Laser Source
CA92050-KT
-
The CA92050-KT 2 kHz fast swept tunable laser modules offer superior performance for the test of Fiber Vibration Sensing, DWDM components, AWG , WSS, OPM components, Fiber sensing( especially for vibration fiber sensing application) , optical amplifiers, and other general purpose of fiber optical test and measurement with high wavelength resolution applications.
-
Product
Full C-Band or L-Band Tunable Laser Source
LTS-2000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
The LTS-2000 series full C-Band or L-Band quick adjustable laser optical source , is a 2U small model of high precision and muti-function, can be set up 1~4 port independent C or L band adjustable optical source. Various flexible configurations optional (see more in product series) , and makeing daily test and measurement applications greatly convenient.
-
Product
Compact & Robust Tunable Laser
WSL-110
-
Designed for use in fiber optic transmission testing, our WSL-110 can also be used for DWDM component evaluation and coherent communications testing. The WSL-110 features grid tuning and gridless tuning options, allowing any wavelength to be accessed.
-
Product
Tapered Laser
Tiger Littrow
-
Monolithic Tapered Littrow Tunable External Cavity Laser, 750nm .. 1080nm, up to 1000mW, patented technology, monolithic cavity design, hands-off operation, narrow linewidth, up to 30GHz mode-hop free tuning, free space and fiber coupled versions. Check our tapered diode stock list for availability.
-
Product
Desktop Tunable Laser Source
GM8042
-
The GM8042 desktop tunable laser sources offer superior performance in testing DWDMcomponents, AWG & PLC components, optical amplifiers, DWDM system and performing other general-purpose fiber optical test and measurement applications. It is a high wavelength accuracy, high power output, compact dimensions, fast startup, and affordable tunable laser source system. UC INSTRUMENTS provides C band, L band, or C+L band tunable laser sources options.
-
Product
Extractive Gas Analyzers
Advance Optima and EasyLine Series
-
ABB offers three series of extractive gas analyzers catering to a diverse range of industries and applications. Sensing technologies perfected over more than 90 years are the foundation for a modular architecture delivering market leading performance and reliability – Uras (NDIR), Limas (NDUV), Magnos (Paramagnetic), Caldos (TCD), Fidas (FID), ZO23 (Zirconia). ABB also offers tunable diode laser (TDL) analyzers that measure in situ, directly at the stack or process line. The analyzers are world renowned for ruggedness, easy installation and operation in safe and hazardous areas, simplified calibration and outstanding possibilities for integration in digital networks.
-
Product
Sensing System
FBG
-
A cost-effective FBG (Fiber Bragg Grating) interrogation system that includes a tunable laser diode, 6 photodiodes, and several fiber-optic couplers has been developed with very simple coniguration. Especially, it is not necessary to compensate the accurate wavelength because the wavelength sweeping is precisely performed in terms of the response time of which external cavity material is 5 msec. Moreover, time-varying temperature trends as well as spectra of FBGs can be observed through the front display.
-
Product
Optical Receiver Stress Test Solution
N4917B
-
The N4917B software provides an automated standard compliant stressed receiver sensitivity test according to 100GBASE-LR4, ER4 and SR4 test specification. In order to do this kind of test, several test instruments such as a bit error ratio tester, digital sampling oscilloscope, optical reference transmitter and tunable laser source are required to operate together to achieve a compliant, repeatable optical stressed eye. This stressed eye is then fed to the receiver under test, where bit error ratio is measured under the stress conditions as defined in the standard.
-
Product
Tunable Laser Source - MATRIQ
Laser Source
The Laser 1000 Series is a fully-compliant micro-ITLA laser with up to four channels in a compact benchtop form factor.Offering 0.01 pm resolution tunability across C or L bands, exceptional power accuracy up to 16.5dBm, and optional dither suppression, this is a versatile and cost-effective general purpose instrument.
-
Product
Tunable Wavelength Systems (OPOs)
NT342 Series
-
NT342 series tunable laser system comprises a nanosecond optical parametric oscillator and Q-switched pump laser in a single housing. The system features up to 50 mJ in VIS, no-gap wavelength tuning from 192 nm to 2600 nm, up to 30 Hz repeptition rate, easy maintenance and separate output for pump laser beam.
-
Product
110 GHz Lightwave Component Analyzer
N4372E
-
The N4372E lightwave component analyzer helps you with optoelectronic tests with its measurement capability of 110 GHz in an extended wavelength range. It also offers RX testing up to 110 GHz in the full 1260 nm to 1620 nm range. It has a built-in optical power meter that enables you to check and control the operating power. The N4372E lightwave component analyzer's optical transmitter input port connects to an auxiliary tunable laser to verify S-parameters over wavelength.
-
Product
Ultimate Performance Tunable Laser
TSL-770
-
Santec’s all new TSL-570 capitalizes on Santec’s 33 years’ experience in tunable laser manufacture. The TSL-570 is a high performance tunable laser with a wide tuning range and an output combining high power and high signal-to-noise ratio. It uses a new optical cavity design with precise speed control up to 200 nm/s and sub-picometer resolution and accuracy.
-
Product
Pulsed and CW lasers, 375 – 1700 nm, 1 kHz measurement rate
871 Series
-
The 871 Laser Wavelength Meter from Bristol Instruments is the best way to measure the absolute wavelength of both pulsed and CW lasers and OPOs. By combining proven Fizeau etalon technology with automatic calibration, the reliable accuracy needed for the most meaningful experimental results is ensured. What’s more, a sustained measurement rate of 1 kHz enables the wavelength characterization of every single pulse for most lasers. And, the resulting time resolution of 1 ms provides the most detailed analysis of tunable lasers.
-
Product
Compact Tunable Laser Source with Continuous Sweep Mode, 1520nm to 1630nm
81940A
Laser Source
Keysight's 81940A high power compact tunable lasers enables optical device characterization at high power levels and measurement of nonlinear effects. It's improves the testing of all types of optical amplifiers and other active components as well as broadband passive optical components. As single slot plug-in modules for Keysight's 8163A/B, 8164A/B and 8166A/B mainframes, they are a flexible and cost effective stimulus for single channel and DWDM test applications. Each module covers a total wavelength range of 110 nm in the C+L-band.
-
Product
Product Range
Solus
-
Introducing Protea's new range of laser gas analysers - Solus. The Solus platform represents an extension of Protea's spectroscopic gas analysis equipment into laser based technology, allowing for highly selective, quick response and low range measurements of 1 or 2 gases in a cost-effective, re-configurable package. Solus utilises the latest in Tunable Laser Diode Absorption Spectroscopy (TDLAS), together with the best in micromachining technology, to deliver a precisely controlled narrow wavelength that can be tuned over a small range. The narrow linewidth allows for selection of precise spectral absorbance in the NIR region, free from cross-interferences of other absorbing gases. For some tuning ranges, a number of gases can be measured by tuning a single laser diode e.g. NH3 and H2O.
-
Product
Continuous-wave (CW) Lasers
-
Continuous-wave lasers (cw lasers) emit a continuous laser beam as compared to ultrafast or pulsed lasers that emit a pulsed laser beam. Spectra-Physics offers wavelength tunable cw lasers, standard cw lasers, quasi-cw lasers, and accessories for continuous-wave lasers.
-
Product
Tunable Laser Hydrogen Chloride Analyzer
TX-100
-
Laser HCl analyzer with a probe type optical system which employs direct insert method. TX-100 is suitable for monitoring HCl concentration in incineration plants and the control of HCl removal process in various industries including cement factories and petrochemical plants, etc.
-
Product
Multi-Function Test & Measurement System
-
Optoplex’s Multifunction Test and Measurement System (TM100 Series) is designed to provide a flexible and cost effective optical test and measurement solution, particularly for manufacturing lines. The mainframe can be mounted in 19” rack or stationed on desk-top for ease of use. There are many selections of the pluggable modules, from tunable laser, optical spectrum analyzer, EDFA, power meter, ASE light source, optical tunable filter, optical performance monitor, …, etc.
-
Product
PC Control Tunable Laser Source Modules
UC9710xx
-
The UC8710C, UC9710L and UC8710CL tunable laser modules offer superior performance in testing DWDM components, AWG & PLC components, and optical amplifiers, and performing other general- purpose fiber optical test and measurement applications particularly in fiber grating sensor fast sweep testing.
-
Product
Tunable Laser Source
-
AP405xA series tunable laser sources are high performance external cavity Littman tunable lasers combining wide tuning range, high output power and high signal-to-noise ratio. Different wavelength ranges are available between 1000 nm and 1650 nm. Tunable laser sources OEM and stand-alone benchtop instrument versions are available. The TLS benchtop instrument is proposed with a friendly-user software, a touch sensitive screen, GPIB, ethernet , RS-232 and USB controls.
-
Product
Reference Transmitter
81492A
Transmitter
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
Product
Automated Coherent Receiver Tester
CoRx Tester.
Receiver Tester
Quantifi Photonics’ CoRx Tester provides automated measurement of key coherent receiver performance parameters. The CoRx Tester is comprised of a pre-configured PXI chassis, a two-channel tunable laser, a polarization controller, and a two-channel Variable Optical Attenuator (VOA) with built-in power meter. Just connect the two optical outputs to your Integrated Coherent Receiver (ICR), connect your ICR to the oscilloscope and let the CoRx Tester software do all the rest.
-
Product
Four-Port Tunable Laser System Source
N7714A
-
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
Reference Transmitter
81491A
Transmitter
Keysight's 81491A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 32Gbaud and can serve as universal E/O converter. It comes in Multimode (MM) and Single-Mode (SM) flavors and includes internal lasers at 850nm (MM) or 1310&1550nm (SM). External optical input for usage with tunable laser sources is available for SM option. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.





























