  • Analog Sensors

    Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Analog Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available, to fit any application, including germicidal applications, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information. Typical current draw is under 1mA. (By contrast, Digital models are typically used as discrete sensors that are portable and located to provide short term information.)

  • Digital Sensors

    PMA-Series - Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Digital Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available to fit any application, including germicidal requirements, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Digital Sensors if you prefer to plug into our PMA-Series Radiometers to read the output of the sensor on the meter’s display. Digital models are typically used as discrete sensors that are portable and located to provide short term information. (By contrast, please select Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information.)

  • UV Light Meter

    Model 308T - OAI

    Built for high intensity applications the NEW OAI Model 308T UV Light Meter is a dependable, direct-reading instrument designed for measuring UV light intensity for UV curing. The Model 308T features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port. Accuracy of the meter is within ±3%and measurement repeatability is within ±3 LSB (least significant bit). Like all OAI precision instruments, the Model 308T provides NIST traceable measurements. This easy-to-use meter is auto-ranging from 0.1 to 1999.9 milliwatts/cm2 full scale when used with the 2000 milliwatts/ cm2 probe. The linearity of the meter in this range is at least ±(.002% + 6 LSB).

  • UV Lamp Weathering Test Chamber

    Sanwood Environmental Chambers Co ., Ltd.

    Sanwood is a company with professional research and development, sales of Bench-top UV test chamber,Bench-top UV lamp aging test chamber,Bench-top UV weathering test chamber,Bench-top UV aging test chamber,Bench-top UV aging test chamber for 23 years. Ultraviolet light in the sun is a major contributor to the durability of most materials. We use UV lamps to simulate the short-wave ultraviolet portion of sunlight, which produces very little visible or infrared spectral energy. We can choose UV lamps of different wavelengths according to different test requirements, because each lamp has different energy and wavelength in total UV irradiation. Generally, UV lamps can be classified into two types: UVA and UVB.

  • Radiometer

    X1-1-RCH-116-4 - Gigahertz-Optik GmbH

    The X1-1 radiometer from Gigahertz-Optik features an RCH-116-4 detector and is ideal for measurement of the irradiance of high power LEDs in the UV-A and blue light range. The device can accurately measure irradiance levels of up to 40,000 mW/cm². One of the outstanding features of the RCH-116-4 detector is its proven concept of a passive radiation absorber coupled to a UV sensor. This provides stability even in high temperature and intense UV radiation environments. In addition to the passive radiation absorber, the device also has a cosine-corrected field of view. The sensor’s housing also serves as a handle. The battery-powered X1-1 optometer supports a usable dynamic range from less than 1 mW/cm² to 40,000 mW/cm² thanks to its high-end signal amplifier. It can be used to perform precise measurements of up to 5 standard LED wavelengths for which the detector was calibrated for active irradiance. In addition to the CW measurement function, the device also has a dose measurement function. The radiometer can be used with other detectors from the RCH series. e.g. for gas discharge lamps. Remote control of the device is possible via its user software and a software development kit is offered for integration of the device in the user’s own software.