High Purity Germanium
See Also: HPGe
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
High Current Probe
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
Product
PXIe-7903, 28.2 Gbps, 48-Channel PXI High-Speed Serial Instrument
788917-01
High Speed Serial Instrument
The PXIe-7903 is designed for engineers who need high-performance FPGA coprocessing capabilities or who need to validate, interface through, and test serial protocols. It includes a Xilinx Virtex UltraScale+ FPGA to implement various high-speed serial protocols, and it is programmable with the LabVIEW FPGA Module for maximum application-specific customization and reuse. The PXIe-7903 takes advantage of FPGA multigigabit transceivers to deliver 48 TX and RX serial lanes.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
High Frequency Probe
Your product description goes here.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
68-Pin SCSI-II Female to 68-Pin VHDCI Male, Shielded Digital Cable
191667-01
High Speed Digital Cable
The SHC68-68-RDIO is designed and shielded specifically for the digital I/O connector on supported Multifunction Reconfigurable I/O Device. This cable features digital I/O lines individually twisted with digital ground for high-signal integrity and noise immunity. You also can use the SHC68-68-RDIO with the NI-9151 CompactRIO Chassis.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Godzilla High Current Probe, 100 Amp
HC375
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Brute High Current Probe
P4301-1R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
68-Pin VHDCI Male to 68-Pin VHDCI Male, 80 MHz, Shielded Digital Cable
156166-01
High Speed Digital Cable
The SHC68-C68-RDIO2 is designed and shielded specifically for the digital I/O connector on the USB-7855 and USB-7856 Multifunction Reconfigurable I/O Devices. This cable features digital I/O lines individually twisted with digital ground for high-signal integrity and noise immunity. The SHC68-C68-RDIO2 is available in 1 m and 2 m lengths.
-
Product
4 Tx/Rx Lanes, PXIe-6591 and PXIe-7902-Compatible, Mini-SAS HD X4 High-Speed Cable
783977-01
High Speed Digital Cable
Mini-SAS HD x4 Cable, 3m
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
High Current Probe
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Portable High Purity Oxygen Analyzer
GNL-2100L
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-2100L oxygen analyzer breaks through traditional magneto mechanical measurement and achieves to measure oxygen concentration without benchmark gas by adopting conversion ion current with the world advanced technology as measurement principle. It has observable characteristics of long calibrating period, high precision, small appearance, lower power consumption, - See more at: http://en.ci-ele.com/2d52147a-f981-5670-12e2-94734366ad09/f3d247c5-749f-7352-9f98-7e49e5f790f7.shtml#sthash.OQI9naQH.dpuf
-
Product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
High Current Probe
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
Oxygen Purity Sensors
-
At Process Sensing Technologies (PST) we specialize in offering replacement electrochemical oxygen sensors compatible with major fixed and portable oxygen analyzers, specifically tailored for enriched oxygen applications. PST’s oxygen purity sensors are designed to deliver unparalleled accuracy, ensuring optimal performance in diverse industrial settings.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Gold Purity Tester
PRO‑ALLOY
-
The Easy Way To Test Gold & Platinum Jewelry. Measure the purity of rings, chains, watches and more… Instant gold karat reading • Fast and accurate • Non-destructive.
-
Product
High Resistance Measurement Universal Adapter
N1414A
High Resistance Measurement Adapter
N1414A High Resistance Measurement Universal Adapter is used to simplify the connection for high resistance measurements by B2980A series electrometer.
-
Product
DC Coupled Current Probe
34134A
High Current Probe
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
Product
400 MHz High Voltage Differential Probe
DP0001A
High Current Probe
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Process Purity Oxygen Analyzer
GNL-IN84
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN84 high purity oxygen analyzer breaks through magneto mechanical measurement and achieves to measure oxygen concentration without benchmark gas by adopting vast-contract with the world advanced technology as measurement principle. It has observable characteristics of long calibrating period, high precision, small appearance, low power consumption, etc. - See more at: http://en.ci-ele.com/2d52147a-f981-5670-12e2-94734366ad09/5cb96e1c-9d46-71b5-defc-db00e268d683.shtml#sthash.hTZMaZ9i.dpuf
-
Product
SF6 Gas Purity Tester
-
Weshine Electric Manufacturing Co., Ltd
In operation and during electrical failures, pollutants are generated which, depending on its concentration, reactivity and toxicity, modify the characteristics of gas for insulation and arc extinguishing. This may affect the safety of the installation and people. Gas handling operations can also cause the incorporation of pollutants.