Showing results: 331 - 345 of 424 items found.
-
DSOV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS404A -
Keysight Technologies
4 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.2 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
DSOV084A -
Keysight Technologies
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS254A -
Keysight Technologies
2.5 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.4 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
MSOS604A -
Keysight Technologies
6 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 6.8 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
DSOV334A -
Keysight Technologies
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOS204A -
Keysight Technologies
2 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.5 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15" capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
MSOV334A -
Keysight Technologies
33 GHz analog bandwidth4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV134A -
Keysight Technologies
13 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSAV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
777960-01 -
NI
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
MSOS104A -
Keysight Technologies
1 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.8 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15 inch capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
DSAV204A -
Keysight Technologies
20 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.54 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
DSOV254A -
Keysight Technologies
25 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MAX4950 -
Maxim Integrated
The MAX4950 PCI Express (PCIe®) quad equalizer/redriver operates from a single +3.3V supply. This device improves signal integrity at the receiver through programmable input equalization and programmable redrive circuitry. The output circuitry reestablishes deemphasis lost on the board, compensating for circuit board loss. This device permits optimal placement of key PCIe components and longer runs of stripline, microstrip, or cable.