Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
-
Product
Regenerative DC Electronic Load
IT8000 Series
-
IT8000 series is a family of high power regenerative electronic loads with compact size. The highly integrated capability enables the e-load to simulate various e-load characteristics, and return the consumed energy back to the grid cleanly, saving costs related to energy consumption and cooling, meanwhile eco-friendly. With modular high power density design, IT8000 provide up to 18kW in 3U space.
-
Product
Micro Power or Micro Coax, Insert, Receiver, SIM, 2 Pos, 2 Slot (not loaded)
510180104
-
Not loaded. Micro Power or Micro Coax patchcords need to be purchased separately.
-
Product
Spring Loaded Contacts
-
ATE Probes, Pogo pins and Contact Pads. Gold-plated, spring-loaded, capable of thousands of cycles. Probes for Automated Test Equipment (ATE). Various height SMT contact pins. Flat SMT contact pads. Spring loaded contacts consist of a plunger (or head), barrel (or body), and a fully encapsulated fine spring, to provide the spring force required to maintain positive contact. All have a high durability, exceeding 10,000 mating cycles.
-
Product
External Load Expansion Connector Accessory for USBHub3c
-
Used for connecting external electronic loads to the USBHub3c for VBUS load testing. It features separate screw terminals for VBUS passthrough from each USB Type-C port (0 through 5). While this board provides a physical wiring interface to access each VBUS channel, the USBHub3c External Load Feature is required to enable VBUS outputs on the USBHub3c.
-
Product
20/26 GHz Coax, Insert, Receiver, SIM, 2 POS, 6 Slot (not loaded)
510180110
-
20/26 GHz Coax, Insert, Receiver, SIM, 2 POS, 6 Slot (not loaded)20/26 GHz Coax patchcords need to be purchased separately.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1000B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-23S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra compact size*AC 1A~200A*Current measurements of terminal feeder
-
Product
AC Load Simulating Inductors
-
Osborne designs our AC Inductors to provide the desired inductance and to perform effectively with the dissipation characteristics presented to the circuit. Dissipation characteristics depend on circuit current and operating frequency. The Osborne design approach is unique to the extent that we design for frequency effects. The resulting inductors deliver superior performance.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
Product
PXI 2 Banks of 40 Channel 2 Pole MUX
40-615-022-2/40/2
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Dynacell Load Cells
2527 Series
-
Dynacell is the world's first truly dynamic load cell, designed from the outset for measuring dynamic loads. Dynacell introduces the following advantages: *Reduces dynamic load errors which can be a significant percentage of reading*Increases productivity by allowing higher frequency operation while maintaining test validity *Improvements such as doubling the frequency are common
-
Product
Low Profile Universal Tension or Compression Load Cell
LPU SERIES
-
Our LPU Series are low profile, universal tension or compression "pancake" type load cells. They are available in 14 ranges from 100 lb through 50,000 lb Hold down bolt holes are provided through the outer diameter and a threaded hole provided through the center for pushing or pulling from either end. The ALB load buttons located in our accessories section, are ideal for compression applications. The LPU Series are made from 17-4ph heat treated stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial environments.
-
Product
Press Force Load Cell
6000 Series
-
Press Force Load Cells are strain gage based transducers for press-force monitoring. This type offers capacities up to 100 kN with compensated temperature performances. Cable is contained within a stainless steel spring for strain relief purposes for additional protection.
-
Product
PXI 2 Banks of 32 Chan 1 Pole MUX
40-657-001-2/32/1
-
40-657 High Density Power Multiplexer Modules are available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
Product
ELM Electronic Load Module
-
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
Product
PXI MUX 8 Banks of 8 Channel 1 Pole
40-610-021-8/8/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
-
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
GOLDesp Load Planner
-
Provides automated load-planning capability that assists embarkation specialists in the rapid development of cargo load plans
-
Product
AC & DC Electronic Load
3270 Series (350V,1875W~22500W)
-
3270 Series is suitable for the step, square and sine wave of the AC Power device test, especially for the uninterruptible power supply UPS, Inverter, fuses, circuit breakers, power regulator AVR, battery, AC / DC power supply / components ... and so on, absolutely is the best test solution in the market.
-
Product
Hand-Held/Digital Load Tester
6030
-
• Full 125 Amp load tests 12 Volt batteries, alternators and starters on all type of vehicles• PATENTED• Made in USA of US and Global Components
-
Product
Electronic Load Device
786531-01
-
The RMX-4005 provides capabilities for qualifying power designs and validating power supply functionality in a production environment. You can combine Electronic Load Devices to customize your test system based on the number of channels, maximum load power, and voltage and current of each channel. You can connect multiple RMX-4005 devices in parallel to provide higher power capabilities for your power supply tests. This feature gives flexibility for future projects that have different power requirements.
-
Product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Digital Panel Mount Load Cell Meter
MODEL DPM-3
-
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.
-
Product
48V / 250 Amp Load
BD15-48P-24/12
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 12V, 24V and 48V Battery systems and is extremely cost effective.
-
Product
Terminations And Mismatch Loads
-
JFW’s online 50 Ohm Low power termination and mismatch load models are listed in the table below. JFW has been designing, manufacturing, and delivering quality terminations and mismatch loads for over 30 years. Our mismatch loads allow you to select the impedance mismatch your RF testing requires.
-
Product
Load Cell Transducer
-
Unitech Scales And Measurements Pvt. Ltd
Force can be measured by different methods, one of the most effective and accurate method is by using strain gauge based load cells. Four Transducer class strain gauges are bonded on the specimen and are connected in the form of Whetstone Bridge. The specimens are of different types depending on the requirement such as S, column, beam, ring, shear beam, binocular etc. UNITEH’S Load Cells are used for wide applications rite from commercial weighing scale to industrial process controlling, R & D applications and educational institutions. UNITECH’S manufacture load cells from 1Kg to 100Tons for compression or tension or universal (Compression and tension) applications. We also undertake custom built load cells for specific requirement and for OEM users.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1500B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
-
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)