-
product
16 Channel Power PXI Multiplexer, 2 Pole
40-650-002
A 16 Channel Power Multiplexer, suitable for switching inductive/ capacitive loads up to 5A at 250VAC. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. It is suitable for applications requiring switching of either mains voltage or DC.
-
product
LXI 96-Channel 1GHz Video Multiplexer
60-721A-004
The 60-721A High Performance Video MUX is designed for the switching of RF signals in 75 Ohm systems at frequencies up to 1GHz. It is ideal for 75 Ohm monitoring applications that require a multiplexer to select one channel to be routed to measuring equipment.
-
product
PXIe Microwave Multiplexer, Single SP8T, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-041-E
The 40-788-041-E (PXI) and 42-788-041-E (PXIe) are single failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
product
PXI/PXIe MEMS Optical MUX, Quad 2-Channel, Single-Mode, 9/125 Fiber, LC Connectors
42-855A-442
The 40/42-855A-442 is a PXI/PXIe quad 2-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-784B-142-E
The 40-784B-142-E (PXI) and 42-784B-142-E (PXIe) are dual failsafe SP4T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI Solid State MUX, 20 bank, 8 channel
40-680-001
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber
40-850A-314-M50-HI
The 40/42-850A-314-M50-HI is a PXI/PXIe 4-channel multiplexer with MU (mini SC) connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, SC/PC Connectors, With Interlock
42-852A-218-M50-HI
The 40/42-852A-218-M50-HI is a PXI/PXIe 8-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI 8-slot BRIC Power Multiplexer, 32-Channel, 6-Pole (6 Sub-cards)
40-571A-404
The 40-571A-404 is a 32-channel, 6-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 8-Channel, 8-Pole
42-614D-013
The 40-614D-013 (PXI) and 42-614D-013 (PXIe) 2-bank, 8-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
LXI Microwave Multiplexer, SP4T, 14-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-803-714
Our 60-803-714 is a 14 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
PXI 2A Multiplexer, 1-Bank, 16-Channel 8-Pole
40-614-018
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm SMB Terminated
40-876-002
The 40-876-002 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors
42-850A-114-M62.5
The 40/42-850A-114-M62.5 is a PXI/PXIe 4-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI 5A Power Multiplexer, 1-Bank, 48-Channel, Isolated Common, Independent Isolation
40-651A-111
The 40-651A-111 is part of our range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats.
-
product
Combination SPDT/Multiplexer Module
1260-37
The Astronics 1260-37 contains 40 Form C (SPDT) switches and eight 1x6 multiplexers. The multiplexers can be expanded using the on-board jumpers to four 1x12, two 1x24 or one 1x48 two-wire channel.
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 8 GHz, 50 Ω, N-Type, Failsafe
40-788-011
The 40-788-011 (PXI) and 42-788-011 (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67GHz, 50Ω, SMA-1.85
40-785C-572
The 40-785C-572 (PXI) and 42-785C-572 (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI 2 Amp Multiplexer, Dual 32-Channel, 1-Pole
40-635A-005
The 40-635A-005 is a dual 32-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
PXI 3A Power MUX BRIC, 6-Channel, 48-Pole
40-571-006
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-314-M50
The 40/42-850A-314-M50 is a PXI/PXIe 4-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass
40-860A-342
The 40/42-860A-342 is a PXI/PXIe quad insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-522-TE
The 40-785C-522-TE (PXI) and 42-785C-522-TE (PXIe) are dual failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber, FC/PC Connectors
42-850A-114-M50
The 40/42-850A-114-M50 is a PXI/PXIe 4-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI Multiplexer, 18-Bank, 3-Channel, 1-Pole
40-617A-021
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module is part of our range of reed-relay based switching solutions. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously.
-
product
32-Ch DPST 5A-250VAC 24VDC Multiplexer
YAV90063
The YAV90063 module is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It uses high quality electro-mechanical relays allowing each channel to switch voltage up to 220VDC/250VAC.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber
40-850A-214-M50-HI
The 40/42-850A-214-M50-HI is a PXI/PXIe 4-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI Very High Density Multiplexer, 99-Channel, 2-Pole
40-675A-002-99/2
The 40-675A-002-99/2 is a 99-channel, 2-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 64-Channel, 1-Pole
40-614D-010
The 40-614D-010 (PXI) and 42-614D-010 (PXIe) 2-bank, 64-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 2-Pole
40-321-129-HI
The 40-321-129-HI (PXI) and 42-321-129-HI (PXIe) are single 48-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.





























