Thermocouple Calibrators
-
Product
Calibration Software
-
Simplify your calibration through advanced software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
-
Product
Surface Calibrators
-
Electronic Development Labs, Inc.
A software-driven process for gaming mice that optimizes the sensor to a specific surface's texture, reflectivity, and weave.
-
Product
N-port Calibrated Measurements
S97551B
-
The S97551B software enables full multiport error correction and measurement capabilities when using multiple USB vector network analyzers
-
Product
Calibration
-
ION Science recommends that your instruments are recalibrated on an annual basis to ensure they continue to provide you with accurate, reliable results and that they maintain their extended warranty. Choose the right calibration solution from our range below.
-
Product
Waveguide Calibration Kits
-
Designed to provide accurate calibration of vector network analyzers (VNAs) that are used for measurements in standard rectangular waveguide from 2.6 to 50 GHz (WR284–WR22).
-
Product
Hart Multifunction Calibrator
Model 26 / 26 H
-
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
Product
Light Meter Calibration Services
-
International Light Technologies
International Light has been offering light meter calibration services since we created the first USA-made light measurement system in 1965. Our full service calibration lab offers ISO 17025 Accredited (UKAS recognized) calibrations and certifications that are also N.I.S.T. Traceable.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
Product
Basic Quad J-Type Analog Thermocouple Amplifier
SEN-30103-J1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Balanced and UFL Calibration Kit
CAL-UFL-BAL
-
The Balanced Calibration Kit is an interface kit for UFL and balanced VNA measurements. It contains SMA-UFL adapters and several adapters from SMA and UFL to balanced pinheaders. The UFL connector was introduced by Hirose as the U.FL connector and became very popular for connecting RF signals in consumer electronics. There are several varieties from other manufacturors and are also known as UMC or UMCC connectors.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
CrystalCalHP Calibration System
-
AMETEK Sensors, Test & Calibration
This portable gauge and transmitter calibration system is 7 to 10 times faster than a deadweight tester. It allows you to do a 10 point up and down calibration in less than 3 minutes including printing out a calibration certificate.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Precision Calibrated Noise Sources
-
ELVA-1's calibrated noise source ISSN-XX series delivers a uniform level of noise power spectral density within the whole waveguide frequency range. Sources are available in eight waveguide bands covering 26.4-170 GHz.
-
Product
Calibration Solutions
Software
-
SPEKTRA Schwingungstechnik und Akustik GmbH Dresden
The CS18 software was created in close cooperation with the SPEKTRA Calibration laboratory accredited by DAkkS. It meets the demands of every efficiently operating calibration laboratory already in its basic configuration and can easily be adapted to the workflows of any company.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Furnace Calibrators
-
Electronic Development Labs, Inc.
High-precision heating instruments designed to calibrate temperature sensors.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Automated Probe Calibration
AutoClock
-
Metrology Software Products Ltd
AutoClock is the first product in history which makes it possible to fully automate the probe calibration process. It provides fast, accurate and automated tool axis setting. It takes seconds to automatically set the tool axis offset to microns. This enables the probe to complete the automatic calibration process without human intervention.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
On-Site Calibration Services
-
Labsphere offers on-site spectral radiance calibration services for HELIOS and other uniform source systems.
-
Product
Calibration Kit
FMCK1000
-
Designed to withstand daily use in high-traffic environments such as in the testing lab or on the production floor. This cost effective calibration kit provides reliable and accurate instrument tuning for all of your test and measurement requirements. Applications: VNA, Full 2-Port CAL VNA, Thru CAL VNA, Substitution CAL method Test & Measurement Lab Equipment Accessories Engineering Test and Evaluation General Purpose Test and evaluation.
-
Product
Microwave Measurements & VNA Calibrations
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
For microwave measurements and VNA calibrations, Rosenberger develops, manufactures, and provides test & measurement products which meet the highest demands of industrial test applications. These include high-performance VNA test cableswith outstanding phase and amplitude stability, a variety of test port adaptors for VNA applications up to 110 GHz, very robust interchangeable high mating cycle port connector systems, and test devices – from low-frequency devices for simple measurements to components permitting high-precision broadband measurements.
-
Product
Calibration Substrates
-
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected
-
Product
Calibration Hangers And Weights
-
Calibrated Dead Weight are the official means by which torque analyzers and torque sensors are calibrated and are traced to National or International Standards, such as N.I.S.T, ISO and others. Many industries like as medical, aerospace, nuclear and others continuously calibrate their measuring equipment to comply with government regulations. For companies that prefer to have calibration capabilities in-house when their calibration requirements become extensive, they need calibration equipment.
-
Product
Differential Calibration Substrates
-
The GGB Industries, Inc., line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected.
-
Product
Dry Block Calibrator
-
We offer temperature dry blocks in different models; we offer easily portable and fast temperature blocks for field use and high accuracy temperature blocks for laboratory use.
-
Product
Temperature & Process Calibrators
-
The most sophisticated industrial equipment will not be useful unless it is calibrated. GAOTek Process Calibrators are used to adjust instruments’ accuracy, and they are the only process calibrator you will ever need to carry. They can measure temperature, pressure, voltage, resistance and frequency, and can be used during troubleshooting. Through calibration, you can ensure that any equipment performs as expected and that it can be relied on to deliver predictable and accurate results that meet quality standards. GAOTek Process Calibrators come with a USB interface which makes it easier to transfer the results to other devices which otherwise would have taken a long time to transcribe them. Our Process Calibrators are for sale to the United States, Canada and globally.
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.





























