product
High-Capacity Power Relays
Panasonic Industrial Devices Sales Company of America
High voltage and high current control for DC loads. Applications include: Battery Testing Equipment, Cogeneration Systems, Construction Machinery, Automatic Guided Vehicles, Welding Equipment, Inverter Control, Solar Power Generations Systems and Elevators.
-
product
High-Voltage Dividers & Capacitors
Measurements International Ltd.
300 V to 300 kV, Outputs of 120 Vac, Primary Standard HV Measurements, Loss Measurement Systems, IEEE-488 Interface, Division Accuracy < 20 ppm, Calibration Period 3 to 5 Years.
-
product
Metal Alloy Low Resistance Chip Resistor
MR
*Low Resistance / TCR / Inductance*Excellent long term stability*RoHS compliant and halogen free*Lead free*High precision current sensing and voltage division
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Digital CC and CV DC Power Supply
DC3005
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and can output costant current or constant voltage. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer’s request.
-
product
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
PCI 2 Amp Multiplexer, Quad 8-Channel, 2-Pole
50-635A-009
The 50-635A-009 is a quad 8-channel, 2-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
Capacitor Leakage Current/IR Meter
Chroma 11200
Chroma Systems Solutions, Inc.
The 11200 Capacitor Leakage Current / IR Meter is mainly used for electrolytic capacitor leakage current testing and aluminum-foil withstand voltage testing (EIAJ RC-2364A). The 11200 can also be used for active voltage checking or leakage current testing of absorber, Zener diode, and Neon lamp etc. With the standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities, the Chroma 11200 can be used for both component evaluation on the production line and for fundamental leakage current or IR testing for bench top applications.
-
product
Cable Fault Meter
A cable fault meter can locate open power cables, either live or dead (without current), with voltages up to 300 V. A cable fault meter can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power from the cable which is being tested. Many cable fault meter devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy.
-
product
PXI/PXIe High Voltage Multiplexer, Triple 7-Channel, 1-Pole
42-321-102-HI
The 40-321-102-HI (PXI) and 42-321-102-HI (PXIe) are triple 7-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
10KV Withstand Voltage Tester
Shenzhen Chuangxin Instruments Co., Ltd.
10KV withstand voltage tester High voltage tester, Hipot Tester fast shipping high quality
-
product
HV AC Hipot
The HV AC Hipot package is a hardware and software upgrade available for select Eclypse Analyzers. This package adds a High Voltage AC stimulus source CCA to the analyzer chassis and the HV AC Stimulus utility provides the software drives for ELITE to integrate AC Hipot into test programs.
-
product
High Voltage Tester
Aarohi Embedded Systems Pvt. Ltd
AAROHI make high voltage tester is specially designed to test induction & submersible motors with cutting edge technology.High Voltage Tester is manufactured as per the International set standards and regulations. This High Voltage Testers are available in AC and DC types and are used for testing HV cables after installation and repair for ensuring efficient performance. It also indicates voltage withstands level and current leakage level of the cable during the testing period.
-
product
Dry Arc Resistance Tester
Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a...show more -
product
Backplane Test System
402HV
Our model 402HV is the result of 25 years of high voltage / high pin count test systems experience. We produced our first high voltage system back in 1985. It was programmable up to 600 volts / 600 Mohms and had over 49,000 test points. It could test a 5k point board in less that 15 seconds. Since then we have built hundreds of high voltage test systems, with our highest voltage system capable of testing up to 2000 Volts DC / 1500 Volts AC. (One of our 600 volt systems, built in 1986 is still in operation testing boards for a defense contractor.)
-
product
NIM Power Supplies And Bins
ORTEC offers two types of power supplies for use with NIM instrumentation: power supplies that provide operating voltages for a detector (more properly called detector bias supplies or “HV” supplies) and power supplies that provide the necessary operating voltages for NIM Modular electronic instruments in the form of a NIM “Bin” with associated power supply.
-
product
DC Programmable Electronic Load
ELCH300
- VFD display- High resolution 0.1mA/1mV- Voltage range 0V to 500V- Working mode CV/CC/CW/CR/OV/OC/- OP/OT protection- Communication: USB/RS232/GPIB
-
product
PXI/PXIe High Voltage Multiplexer, Dual 11-Channel, 2-Pole
42-321-125-HI
The 40-321-125-HI (PXI) and 42-321-125-HI (PXIe) are dual 11-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Coil Tester
Koyo Electronics Industries co., ltd
The Coil Tester can measure the number of winding, layer short and core material by comparing vibration waveforms of the applied voltage to the standard coil and the test coil. This instrument also can find an insulation failure by applying high pulse voltage and checking the corona discharge.
-
product
Cable Assembly, 50-Pin D-Type, Female to Female, 0.5m
A050DF5-050DF5-HA050
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assemblies can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
product
High Voltage Probe: Single-Ended
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for oscilloscopes with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
product
Differential Probe
DP-35
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Other Switching Power Supplies
PeakTech Prüf- und Messtechnik GmbH
The switching power supply technology used ensures high performance with a small size and low weight. 6 different DC output voltages (3 V / 4.5 V / 6 V / 7.5 V / 9 V and 12 V) can be set using a slider. With the 4 mm pole terminals, you can easily connect single wires but also 4 mm banana plugs. The power cord with an Euro plug is firmly connected to the power supply unit, whereby the device is switched off and on via a rear power switch. This handy power supply fits on every work bench and can be used universally in the hobby area, service or training.
-
product
High Power DC Electronic Loads
63200A
Chroma Systems Solutions, Inc.
Chroma High Power DC Electronic Loads provide wider operating voltage and current ranges up to 240kW, sine wave loading, dynamic frequency sweep to 50kHz, digitizing, MPPT, an impressive front panel that tilts, and the highest accuracy available (voltage 0.015% + 0.015% F.S. and current 0.04% + 0.04% F.S.) – all with an incredibly high power density (6kW @4U).
-
product
LXI High Voltage Switching
65-233-901-HI
The 65-233-901-HI plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
L.V. Current Transformers
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
product
Low Noise Test Cables For N1413 With B2980 Series, 1.5 M
N1427A
The N1427A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It comes with a separate triaxial (special screw-type) female connector and a High Voltage BNC (special type) female connector. This allows terminal configuration to be converted to any other configuration. Therefore, custom test fixture can easily be constructed. The N1413A High Resistance Meter Fixture Adapter is also required to connect the N1427A to the B2985B/87B.
-
product
High Power DC Power Supply
*Low ripple and low noise*High resolution and accuracy (0.1mV/0.01mA)*Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter*Supporting high-accuracy and dynamic programming output*High-luminance VFD screen with two lines& four channels display*Intellegent fan system fan will be automatically initiated according to the temperature*Supporting remote voltage compensation and multidata storage*Supporting external trigger input and output*Power-on-self-test, software calibration and standard rack mount*Using standard SCPI protocol*Communication mode: RS232/RS485/USB.
-
product
PXI Single 24:1 High Voltage Power MUX
40-331-001
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614B-014
This 2-bank, 4-channel, 16-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.