Reflectors
-
Product
Trihedral Corner Reflectors
TCR Series
-
Precision radar cross section measurements demand precision calibration targets like the TCR Series trihedral corner reflectors. Manufactured to close mechanical tolerances, TRC trihedrals provide reliable and repeatable calibration standards over a wide frequency range through 100 GHz. Surface flatness and perpendicularity are maintained to 1/100 of a wavelength to insure close agreement with theoretical performance.
-
Product
Compact Range Reflectors
-
The company advances every aspect of reflector system development—from design and fabrication to surface characterization, transportation, installation, and electromagnetic evaluation.
-
Product
Cassegrain Antennas
-
In telecommunications and radar, a Cassegrain antenna is a parabolic antenna in which the feed antenna is mounted at or behind the surface of the concave main parabolic reflector dish and is aimed at a smaller convex secondary reflector suspended in front of the primary reflector. The beam of radio waves from the feed illuminates the secondary reflector, which reflects it back to the main reflector dish, which reflects it forward again to form the desired beam. The Cassegrain design is widely used in parabolic antennas, particularly in large antennas such as those in satellite ground stations, radio telescopes, and communication satellites.
-
Product
Retroreflector
10703A
Retroreflector
The Keysight 10703A retroreflector (cube corner) is a basic measurement reflector for linear measurements. It is paired with the Keysight 10702A (or Keysight 10702A Opt. 001) linear interferometer, enabling general-purpose, single-axis measurements. If mass is critical, the Keysight 10703A is available without housing as the 10713B.
-
Product
Angular Optics Kit
55281A
Accessory Kit
The Keysight 55281A Angular Optics Kit adds pitch and yaw measurement capability to the 5530 Laser Calibration System. Ideal for use in precision calibration applications, it includes the 10770A Angular Interferometer and the 10771A Angular Reflector. Together the high-accuracy plane mirror interferometer and the angular reflector measure pitch and yaw motions along each axis that a machine tool or measuring machine travels. Results are displayed directly in arc-seconds or in mm/mm (in/in).
-
Product
Radiometers
-
UV Intensity Meters & Visible Intensity Meter for Light Curing Systems. Dymax UV and visible radiometers are simple to operate and allow operators to monitor and document a UV/Visible light curing process. A low UV/Visible intensity measurement signals an operator to replace the bulb, reflector, or lightguide. Radiometers can also be used to confirm that operators are properly shielded from UV/Visible exposure. Degradation of curing bulbs, lightguides, and reflectors can decrease intensity, resulting in incomplete cures.
-
Product
High Stability Plane Mirror Interferometer
10706B
Angular Interferometer
The Keysight 10706B High Stability Plane Mirror Interferometer is a dual pass interferometer used for multiple axis applications such as X-Y stages where the measurement mirror may move perpendicular to the measurement axis. This thermally stable optic, an exact functional replacement for the 10706A Plane Mirror Interferometer, reduces thermal measurement drift to 1/12 the value typically achieved by conventional plane mirror interferometers. The unique contribution of the 10706B is its tolerance of angular misalignment of the plane mirror reflector. The 10706A can accept a range of measurement mirror angular alignment changes.
-
Product
Short Range Straightness Optics
10774A
Optical Module
The Keysight 10774A Short Range Straighness Optics combines a straightness interferometer and reflector to make measurements over a range of travel up to 3 m (10 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.04 micrometer (1 uin).
-
Product
Antenna Test Chamber for Automotive Radar
ATS1500C
-
The R&S®ATS1500C radar test chamber is a compact antenna test range (CATR), consisting of a gold-plated parabolic reflector and a two-axis positioner for 3D movements of the radar module. Combined with the R&S®AREG800A target simulator and other Rohde & Schwarz test and measuring instruments, it can be used for a variety of applications, including antenna characterization, module calibration, RF performance validation, interference testing or in-band compliance testing. The chamber is equipped with a universal feed antenna which gives access to both polarizations in parallel. Automated temperature testing over the range of -40 to 85°C is possible with an optional enclosure.
-
Product
Reflector
NetProbe 10GR
-
The NetProbe 10GR reflector provides loopback functionality in a low-cost, handheld device. It’s a smart loop device that swaps the source and destination addresses in MAC and IP headers as necessary to run Ethernet performance tests.
-
Product
Linear Interferometer
10766A
Linear Interferometer
The Keysight 10766A Linear Interferometer is used for general purpose single axis measurements and can be employed when the interferometer is the moving component, instead of the measurement reflector. It has a rugged, thermally stable stainless steel housing.
-
Product
1-Inch Cube Corner
10713B
Retroreflector
The Keysight 10713B cube corner reflector can be used as the measurement reflector for linear measurements. It may be paired with either the 10702A Linear Interferometer or the 10705A Single-Beam Interferometer. Supplied without housing, the 10713B is suited to applications where mass is extremely critical.
-
Product
Rack based antenna test system
R&S®ATS800R CATR
Test System
Very compact far-field over-the-air (OTA) test system based on compact antenna test range (CATR) technologyUnrivaled quiet zone size within 0.8 m2 footprintState-of-the-art reflector ensuring a high quiet zone accuracyUnique rack based CATR system supporting over 50 GHzIndirect far-field method (approved by 3GPP for 5G OTA testing)
-
Product
Sensors for Positioning
-
Leuze electronic GmbH + Co. KG
With moving system parts that need to automatically work together, the positioning of parts or work pieces with millimeter accuracy is of great importance. For this purpose, sensors with various operating principles are provided: laser distance measurement devices that measure against a reflector, bar code positioning systems whose red light laser determines position and speed relative to a bar code tape, sensors for optical guidance using edge detection as well as solutions for camera-based compartment fine positioning.
-
Product
Thermopile Detectors and Sensors
-
Our Thermopile Detectors are typically Thermopiles with integrated Thermistor providing analog output in various packages. Special designs include built-in lenses or reflectors to enhance sensing performance, Isothermal constructions, or Dual narrow-band windows. Our latest Thermopile Sensors include specially designed electronic circuitry to provide calibration, digital output, and functionality. With the DigiPile, Excelitas offers a unique design for measurement applications. With its digital output, this device does not require any low noise amplification. The CaliPile family provides integrated features that enable measurement, as well as presence detection applications.
-
Product
Interferometers
-
* Michelson Interferometer with a stabilized single-frequency He-Ne Laser as scale *Measurement range: up to 80 m *Resolution: 5 pm *Wide acceptance angle (up to ± 22.5°) for ball/hollow cube reflector
-
Product
Solar Simulation
-
Sciencetech solar simulators produce high intensity, uniform illumination on a target area. Typically, high power solar simulators use an ellipsoidal reflector to capture light from an arc lamp source inside the reflector, an arrangement that results in a light pattern with a bright outer region and a dark center. This non-uniformity is un- acceptable in many solar simulator applications and as a result, forces many of our solar simulator competitors to use designs involving diffusers to reduce the non-uniformity. This results in a reduction of intensity and a dis- tortion of the spectrum on the target area.
-
Product
Radar Sensor Glossary
-
Expand your radar sensor knowledge in our glossary. Here you will find important fundamentals, definitions, and terms from the world of radar technology and radar sensors. Learn more about radar topics such as resolution, orientation, beamwidth, measurement spot, measurement rate, measurement range, measurement precision, measurement accuracy, linearity deviation, radar reflectors, and other terms related to radar sensors. You can also find more information on radar terms in connection with distance radar sensors in our tutorial on distance measurement with radar .
-
Product
Stroboscope, 5FPM to 12500FPM, 1 %, 110 V, 0 °C, 50 °C
72-7601
-
Type 72-7601 is ideal for measuring the speed of moving gears, fans, pumps, motors and other equipment used in general maintenance, production, quality control laboratories, schools and colleges. The fast find function allows the user to step through pre-programmed value settings when the RPM value is not known. Made from impact resistant plastic with plastic lens and mirrored reflectors
-
Product
Solar Simulation Systems
-
PET Solar Simulators consist of a Light Source with a built-in Lamp Power Supply. The Solar Simulator has an ellipsoidal reflector that surrounds the lamp and collects most of the lamp output. The radiation from the lamp is focused onto an optical integrator that helps produce a uniform diverging beam. The beam is diverted 90° by a mirror onto a collimating lens. Special filters are placed between the mirror and the collimating lens to shape the radiation spectra to match various air masses. The output is a uniform beam that closely matches the sun's radiation spectra for a given air mass. Various models offer different areas of illumination. Each model can be manufactured to simulate the sun's radiation for different air masses.
-
Product
Transmission / Reflection Measurement
-
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
Product
Plane Mirror Converter
10722A
Accessory Kit
The Keysight 10722A plane mirror converter modifies the use of the 10702A linear interferometer. With an additional 10703A reflector, the 10722A converts the 10702A into a 10706A plane mirror interferometer. With an additional 10723A high-stability adapter, the 10722A converts the 10702A into an 10706B high-stability plane mirror interferometer.
-
Product
Incandescent Light Sources
-
Collimated, uniform, 1 inch diameter output beamSupports 75W-300W QTH LampsSupports xenon, mercury, & mercury-xenon arc lampsForced Air CooledRefractive condensing optics attachments availableVariable power supply (purchased separately) with optical feedback (option)Vertically mounted arc lampSide exit port with back spherical reflector
-
Product
Stratum 1 Network Time Server (NTP)
SyncServer S600
-
SyncServer S600 GPS / GNSS, Stratum 1 network time server with security-hardened NTP Reflector™ technology improves the security, accuracy and the reliability of the time services on the network for IT network administrators working to provide network time services in hardened network operations.
-
Product
Long Range Straightness Optics
10775A
-
The Keysight 10775A combines a straightness interferometer and reflector to provide measurements over a range of 1 to 30 meters (3 ft to 100 ft). The optics form a highly-accurate optical straightedge that can measure the straightness of travel of machine-tool and measuring-machine coordinate motions with a resolution of 0.1 micrometer (10 microinch).
-
Product
Plane Mirror Interferometer
10706A
Differential Interferometer
The Keysight 10706A Plane Mirror Interferometer is a dual pass interferometer used for multiple axis applications such as X-Y stages where the measurement mirror may move perpendicular to the measurement axis. The unique contribution of the 10706A is its tolerance of angular misalignment of the plane mirror reflector. The 10706A can accept a range of measurement mirror angular alignment changes.
-
Product
ULTRA-SONIC RECEIVER W/PARABOLIC REFLECTOR
MFJ-5008
-
Many times the noise is coming just outside your doorway, from the power lines. Power companies are usually very willing to help out with noise issues, but not all companies in this age of financial limitations will have the necessary equipment or trained personnel to properly locate nearby noise sources.
-
Product
Reflex Reflector Measurement Systems
-
Photometric Solutions International Pty Ltd
The measurement setup involves using a projector to illuminate the test item, and then measuring the luminous intensity of the light reflected from the test item. The ratio of the luminous intensity emitted by the reflector (in candelas) to the illuminance on the reflector (in lux) is the coefficient of luminous intensity or CIL (cd/lx).
-
Product
Enhanced UV Light Source
Model 30E
-
The Model 30E Enhanced UV Lightsource is highly efficient and may be utilized in a variety of applications. Light is collected by an ellipsoidal reflector and focused on an integrating/condensing lens array to produce uniform illumination at the exposure plane. This UV light source is available in various beam sizes up to 24 inches square with output spectra ranging from 220 nm to 450 nm, using the appropriate lamp (included). Output power ranges from 200 watts to 5 kilowatts. All OAI UV Lightsources are easily equipped with quick-change filter assemblies, enabling the user to customize the output spectrum with little effort. Optional remote exhaust fans are available.
-
Product
Horizontal Profile Projector
-
Sinowon Innovation Metrology Manufacture Ltd.
◆ The lifting system adopts cross roller rail and precision screw drive, which makes lifting drive more comfortable and stable;◆ Coating process reflector, clearer image and great dustproof;◆ Adjustable contour and surface illumination, to meet with difference workpiece demand;◆ Imported high light and long using life LED illumination ,to ensure precision measurement demand;◆ High resolution optical system with clear image and magnification error is less than 0.08%;◆ Powerful Bi-axial fan cooling system,highly increase using life;◆ Powerful and colorful DRO DP400,realized fast and accurate 2D Measurement;◆ Built-in Mini-printer, can print and save data;◆ With standard 10X objective, optional 5X,20X,50X,100X objective,rotary table, foot switch ,clamp, etc.