Showing results: 496 - 510 of 709 items found.
-
HFCT Ø 140mm -
Techimp HQ S.r.L
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
C050FFR-1CP-0A -
Pickering Interfaces Ltd.
This 50-pin SGMC connector is designed to allow users to directly terminate with crimp connections and is suitable for 22 AWG copper wire. Supplied with a backshell that has an integral cable clamp. Screwlocks are provided to secure the connector to its associated product.
-
TF143 -
TESTEX Testing Equipment Systems Ltd.
Fryma Extension Tester, to simply and economically determine the stretch and recovery of textile fabrics, both knitted and woven. The apparatus consists of a loading frame with clamps and a screw tensioning device, two 3kg loading weights and sample cutting templates.
-
LIDOR -
Taurus Powertronics Systems
The Leaky Insulator Detector (LIDOR) is two-piece hand held non-destructive inspection system which utilizes AC/DC Current sensor and Ultrasonic technology for predictive maintenance. The Leaky Insulator Detector (LIDOR) has a Flexible clamp sensor and Ultrasound Receiver.
-
CORONA CAMERA -
Taurus Powertronics Systems
The Leaky Insulator Detector (LID) is two-piece hand held non-destructive inspection system which utilizes AC/DC Current sensor and Ultrasonic technology for predictive maintenance. The Leaky Insulator Detector (LID) has a Flexible clamp sensor and Ultrasound Receiver.
-
TK-4703 -
Gemini Data Loggers Ltd.
Supplied with an input cable, this logger can measure voltages up to 2.5V DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.The unit is particularly useful when space is at a premium.
-
L Series -
Smiths Interconnect
The L Series comes with frames in various lengths to accommodate a variety of module combinations. The frames range from a basic frame with just 2 side rails and 2 end caps, to more complex versions with jackscrews, backshells, cable clamps, etc.
-
410112712 -
Virginia Panel Corporation
This Enclosure gives you the ability to discrete wire to your UUT with secure strain relief provided by the cable clamps located on the back end. The Enclosure is over 2U in height which provides more space for wiring and other test system needs.
-
32900 -
Lisle Corp.
Heavy-duty circuit tester for checking low voltage up to 12 volts. By depressing the red button the tester becomes a jumper for powering electrical components or a ground. The probe, handle, cord and clamp are reinforced for durability. Comes with a strain relief spring on the cord.
-
FST-JD200 DC -
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
DURST Motor & Electric Industries Pty Ltd.
DURST Measurement & Diagnostic Products; circuit tester, vehicle battery analyzer, multimeter, dedicated automotive multimeter, clamp meter, sound level meter, oxygen sensor tester, diesel engine tachometer, multisystem ignition analyzer, faultfinder, circuit tester, diode tester, regulator tester, growler for testing motor insulation, armature/commutator tester, diagnostic testers, current clamps, optical photo/contact tachometer, etc.
-
Canadian Microelectronics Corp.
This fixture clamps to microstrip or CPW lines at the edge of an RF board and is usable at any position without limit on size of circuit. The base is magnetic and it can be locked and released by a knob to accommodate any kinds of circuit configuration. Available for frequency ranges up to 40 GHz.
-
B1604MR-4F-0A -
Pickering Interfaces Ltd.
This connector block provides a simple method of connecting to high density DIN41612 connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. The metal shell includes an internal insulation barrier under the carrier board.
-
HN-B -
Shenzhen Chuangxin Instruments Co., Ltd.
HN-B Series Cap Torque Meter is an intelligent metrologic instrument and is designed for detecting and calibrating the torsion of various caps. Installation of clamps is easy, rapid and its max diameter can reach 200mm.You can connect it to PC by USD output and transmit data for analysis and printing.
-
ifm efector, inc.
*Integrated flow, temperature and wire monitoring*Adjustable switching outputs for monitoring flow and temperature*Clearly visible multi-color LED bargraph display*Signal output via potential-free relay contacts*Connection options: Insulation displacement / screw terminals and cage clamps