Transfer Standards
-
Product
"Standard" RF Low Pass Filters
-
Coaxial Dynamics "Standard" line of RF Low Pass Filters offers several models to choose from at CW power ratings of 100 watts and 200 watts. These filters cover operating frequencies from 88 MHz to 400 MHz with less than 0.5 dB insertion loss and attenuation levels of 40, 50 and 60 dB.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-005
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
Standard Voltage 50 Pin D-Type Connector Blocks and Breakouts for Pickering
-
The connector blocks and breakouts below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-542-E
Switch Module
The 40-782B-542-E (PXI) and 42-782B-542-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
STANAG3910 Electrica lTest And Simulation Modulefor Standard Ethernet
ANET3910-EN
-
STANAG3910 Electrical Test and Simulation module for Standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create run-time applications to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30J
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Standard In-door Forward Optical Receiver
ONR-8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
ONR-8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
PXI Dual Transfer Switch 40GHz 50Ω SMA-2.9
40-782-542
Switch Module
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.
-
Product
Coaxial Transfer Switch, DC to 50 GHz
87222E
Coaxial Switch
Flexibility is essential in signal routing applications, and the Keysight 87222E 4-port coaxial transfer switch offers just that. It provides exceptional repeatability, low insertion loss, and high isolation. These switches provide simplification of design in signal routing and conditioning applications. The Keysight 87222E can be used in a variety of applications such as, a drop-out switch, switching two inputs and two outputs, or signal reversal switching.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-010-005
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
Standard Voltage 9 Pin D-Type Connector Blocks for Pickering Products
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Standard Test Lead Kit
U1168B
Accessory Kit
The Keysight U1168B standard test lead kit is compatible with the Keysight U1230, U1240, U1250, U1270 and U1280 Series handheld digital multimeters.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-010-008
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-8
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
-
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Portable Single-Phase Energy Standard
PEWM-3C-1
-
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-011
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-015-004
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.