High Voltage Switching
route high voltage signals.
See Also: High Voltage, Switching, Switches, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
-
Your product description goes here.
-
Product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
-
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780875-01
-
Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.
-
Product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
-
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
NI-9220, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module
785188-01
-
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The NI‑9220 performs simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. The module is capable of generating 3.2 MB/s of data at the maximum sampling rate. There are two connector options for the NI‑9220: a 36-position spring-terminal connector and a 37‑position D‑SUB connector.
-
Product
NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module
779526-01
-
±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.
-
Product
FD-11603, 8-Channel, ±10 V Voltage Input Device for FieldDAQ
785639-01
-
The FD-11603 can measure up to eight channels with a voltage input range of ±10 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11603 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages. The FD-11603 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11603 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11603 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11603 is ideal for test cell and outdoor environments.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
-
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
RF High Frequency Probes
-
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-02
-
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
PXIe-7903, 28.2 Gbps, 48-Channel PXI High-Speed Serial Instrument
788917-01
-
The PXIe-7903 is designed for engineers who need high-performance FPGA coprocessing capabilities or who need to validate, interface through, and test serial protocols. It includes a Xilinx Virtex UltraScale+ FPGA to implement various high-speed serial protocols, and it is programmable with the LabVIEW FPGA Module for maximum application-specific customization and reuse. The PXIe-7903 takes advantage of FPGA multigigabit transceivers to deliver 48 TX and RX serial lanes.
-
Product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
-
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780874-01
-
Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
-
100 – 187 mil (2.54 – 4.75 mm)
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
-
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
2x8 USB Solid State Switch Matrix, 300 KHz To 6.5 GHz
P9165A
-
P9165A 2x8 USB solid state switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others.
-
Product
Brute High Current Probe
P4301-2F
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-FK180-2
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 26.5 GHz, 50 Ω, SMA, Failsafe, Remote Mount
42-782B-532-E
-
The 40-782B-532-E (PXI) and 42-782B-532-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
Brute High Current Probe
P4301-1Z
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI Hybrid Single SP6T Switch, DC To 26.5 GHz, Terminated
M9157C
-
M9157C operates from DC to 26.5 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input to multiple instruments and routing of multiple input signals.
-
Product
High-Voltage Differential Probe, 70 MHz
N2891A
-
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 18 GHz, 50 Ω, SMA, Failsafe, Remote Mount
40-782B-522-E
-
The 40-782B-522-E (PXI) and 42-782B-522-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 18 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
PXI Flexible Microwave Module, Dual SP6T Terminated 26.5 GHz, Single SPDT 26.5 GHz, 50 Ω, SMA
40-890-004
-
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
Product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass, Single-Mode, 9/125 Fiber, MU Connectors
42-860A-342
-
The 40/42-860A-342 is a PXI/PXIe quad insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
Switch Modules - 16 Two Pole Relays Arranged as an 8x2 Matrix
JX16/AB-2
-
This module has 16 two pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 two pole matrix. It is available with Type S, M or LT reed relays for high speed, long life application.
-
Product
Standard 4.10 (116.00) - 6.50 (184.00) Switch Probe
MSP-3C
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 140Full Travel (mm): 3.56Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 2,140Overall Length (mm): 54.40Switch Point (mil): 30Switch Point (mm): 0.76