Product
NI 9923, Front-mount terminal block for 37-pin D-Sub Modules
781503-01
-
37-Pin Female D-SUB to 37-Pin Female Screw-Terminal, C Series Terminal Block - The NI-9923 includes one 37-Pin female screw terminal with a 37-pin female D-SUB back-end connection to help you connect a circuit to another circuit.
-
Product
NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle
865685-01
-
NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9220, cDAQ-9171, and cRIO-9940 includes the NI-9220 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9220 features 16 channels and 16 simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. Additionally, you can use the NI-9220 to generate 3.2 MB/s of data at the maximum sampling rate.
-
Product
Cable Assembly, 37-Pin D-Type, Male To Unterminated With Ferrules, 0.5m, HV
40-972-037-0.5m-MUHV
-
The 37-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock.
-
Product
sbRIO-9425, Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module
783950-01
-
Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The sbRIO‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The sbRIO‑9425 offers isolation between the input and output banks from channel‑to‑earth ground. Non-enclosed modules are designed for OEM applications.
-
Product
Needle Microprobe
MT-29/3HT
-
Fast-response 29 gauge needle probe, (needle length is 3 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
sbRIO-9219, Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
781027-01
-
Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
-
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Oil Breakdown Voltage Tester
DTL C
-
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.
-
Product
Probe Card
VC20E Lab
-
*20 millimeter ceramic probe card*Optimized for DC parametric test, modeling and characterization, and single site WLR*Can be quickly installed using an interface tool into various interfaces and takes minimal storage space on the test floor*Effective operating temperature range from -65° to 200° C*Leakage as low as 5fA/V. If you require faster settling time, click here*Can be configured with up to 48 probes
-
Product
DC/DC Converter 2 W
REM2-153.3D
-
DC/DC converter 2 W from Recom | input ranges 13.5 - 16.5 VDC | outputs +/-3.3 V | operates in ambient temperature from -40 to +95 °C
-
Product
Emulates Atmel AT89C51SND1
FE-SND1
-
* Emulates Atmel AT89C51SND1 * 62K Code Memory * Real-Time Emulation * Frequency up to 20MHz/3V * ISP and X2 Mode Support * MS-Windows Debugger For C And Assembler * Emulation Headers and Signal Testpoints * Programmer Included * Serially Linked to IBM PC at 115Kbaud
-
Product
Matrix Fiber Optical Switch at Single Mode Type A 1550nm with LC/PC Connector
GLSUN-MEMS-8x8
-
Guilin GLsun Science and Tech Group Co., LTD
Fiber Configurations8x8 portsFiber TypeSM, 9/125 umTest Wavelength1530/1570 nmOperating Voltage4.8~5.5VSwitch TypeNon-latchingFiber Length0.5m±5cmConnectorLC/PCTube Type900 umOperating Temperature-10°C~ +70°CStorge Temperature-40°C ~ +85°C
-
Product
4 Relay Channels, Latching
RY2
-
The RY2 module features 4 individual single-pole, user SPDT Form C (changeover/break-before-make type) relays (channels). Each channel has a common input terminal (C), a normally closed output terminal (N/C), and a normally open (N/O) output terminal. The channel either energizes or de-energizes the relays (close or open) so that the signal provided on (C) may be switched/directed to either the (N/C) or (N/O) terminals.
-
Product
Speed Switch
UDS1000
-
Features• Works with remote / external quadrature pulse frequency outputsensor / incremental encoder (NPN or PNP)• DPDT relay changes state when shaft direction reverses• Reverse-over-speed setpoint adjustment from 0.5-5,000 rpm• Relay resets when reverse motion stops• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Explosion proof/NEMA 4X housing• UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
ARINC 429 XMC Interface Module
XMC-429
-
Avionics Interface Technologies
16, 32, or 64 ARINC 429 channels (up to 32 Tx & 32 Rx) - Programmable Tx channel output amplitude - Programmable high/low speed operation - Eight (8) Discrete I/O (Four (4) inputs, and four (4) outputs) - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection - Data capture filtering, 100% bus recording, and physical bus replay - IRIG‐B time code encoder/decoder for data correlation - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - ANSI Application interfaces supporting C, C++, C#, and .net development - Device driver support: Windows, Linux, and VxWorks (others provided upon request)
-
Product
Low Cost Emulator
EB-C251
-
# Real-Time and Transparent C251 Emulation# supports Intel MCS?251 and Atmel/W&M/Temic C251# Uses Bond-Out Technology# Maximum Frequency Support up to 24MHz# Source-Level Debugger for C, PLM and Assembler# MS-Windows Software# Support for ROMless and ROMed Microcontrollers# 256K Internal Memory# Memory Mapping Capabilities# Real-Time Trace
-
Product
NI-9361, 32-Bit, 8-Channel C Series Counter Input Module
783407-01
-
32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.
-
Product
TrueIR Thermal Imagers
-
Identify abnormalities faster with 4x more in-camera fine resolutionMonitor temperature changes through image logging and temperature trending capabilitiesAbility to focus on objects as close as 10 cm awayCompact, lightweight, ergonomicHigh temperature range (up to 1200 °C)Easy-to-use customizable color paletteConfigurable quick access buttons to easily change settings with one handLong product warranty - 3 years
-
Product
Reference Temperature Calibrator
JOFRA™ RTC-187
-
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.
-
Product
IEEE488 (GPIB, HPIB) PCI-E Interface Card - PCIe Base 1.0a Compliant
GPIB-PCI-E
-
The Windows software set is included with the GPIB card. It is a WDM driver and supports Windows XP/2k/Vista/7/8 (32- & 64-bit 7 & 8), on all PC compatible platforms. Libraries and header files are included for the Visual C++, Visual Basic, MINGW and Delphi development systems. An industry standard compatible GPIB-32.DLL supports nearly all applications designed for that interface, including applications developed for LabView 6+, LabWindows, Agilent VEE, TransEra HT-Basic, Agilent Intuilink, and more.
-
Product
Built For Demanding Environments, The AIM-77S Rugged Case Delivers Reliable Protection With Drop Resistance Up To 120 Cm Onto Plywood.
AIM-77S Rugged Case
-
Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F)Storage Temperature: -10°C ~ 60°C (14°F ~ 140°F)Humidity: 90% @40°C (non-condensing)Drop Protection: up to 120cm onto plywood
-
Product
19" SXGA Industrial Panel Mount Monitor
IDS-3219
-
19" SXGA LCD panel with LED backlight for 20% power saving and environmental protection. 0° ~ +45° C operating temperature, 5-wire resistive touchscreen solution or 3mm tempered smudge resistant protected glass.
-
Product
DCDC
DP Series
-
The DP family is an economically priced high performance series of regulated DC/DC converters offering single and dual outputs. Features include MOSFET design operating at a switching frequency of 100Khz, continuous short circuit protection, LC input filter, 500 Vdc I/O isolation, and an operating temperature range of -25°C to +71°C with no derating. These miniature converters maintain excellent regulation over varying line and load conditions (0.2% for line and 0.5% for load). They are packaged in an IC compatible 24 pin DIP configuration measuring 1.25” x 0.8” x 0.4” high.
-
Product
RFID Reader For UPOS-211 Series
USC-P03-B201
-
Interface: pinhead USB, Frequency: 13.56 MHz, OS spport: Windows, Linux, Android, Operating temperature: 0°C ~ +50°C.
-
Product
Endurance® High Temperature Infrared Pyrometers
-
The Endurance® Series of infrared pyrometers features rugged and flexible instruments designed to meet the demands of harsh industrial environments and provides continuous visual process monitoring in a wide range of applications and temperatures ranging from 50 to 3200°C (122 to 5692°F).
-
Product
Pico-ITX SBC With Intel® Atom® Processor E3845/E3827, LVDS/ VGA (HDMI), LAN And Audio
PICO840
-
The PICO840 ultra-small Pico-ITX embedded SBC supports the quad-core Intel® Atom® processor (code name: Bay Trail-I) and supporting DDR3L-1066/1333 MHz system memory up to 8 GB. Considering different environments, this industrial-grade Pico-ITX mainboard is built to withstand extreme temperature, ranging from -40°C to +70°C (-40°F to +158°F). Moreover, with superior integration and power efficiency, this compact size single board computer enables system developers and OEMs to create smaller, lighter, quieter devices than ever and embrace the new possibilities across POS systems, mobile medical monitor, compact panel PCs as well as multiple embedded computer, system and appliance segments.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Beer Refractometer
PA203X-009-800-801-802-804
-
Multi-scale Digital Beer Refractometer for measuring Plato, Dissolved Solids, Specific Gravity D20/20, Brewer’s Points, and Propylene Glycol Freeze Point °C.
-
Product
Automatic Metallic Pendulum Impact Testing Machine
-
Jinan Testing Equipment IE Corporation
JB-450/750A automatic type pendulum impact tester is used to determine the impact resistance of metal materials under dynamic load and is capable of doing a large number of impact tests continuously. The automatic type pendulum impact tester can display the impact power, impact toughness, and the pendulum's rotation angle. All the testing reports can be printed out. JB-450/750A can be equipped with fully automated sample feeding system, which greatly improves the test efficiency, and reduce labor intensity. The crygenic cooling device is available for impact tests under the lowest temperature down to -196 C. The automatic type pendulum impact testing system is the essential quality control equipment for metal material manufacturers and QC departments, as well as the necessary instrument of research institutes for new material research.