- Pickering Interfaces Inc.
product
PXI Standard Programmable Resistor Modules
Pickering's PXI Standard Programmable Resistor Modules include fully programmable resistor and potentiometer modules for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Modules can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection. For applications with more demanding accuracy and resolution requirements, consider our Precision Programmable Resistor Modules .
-
product
Fully Automatic Transformer Oil Test Set
OTS-A series
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
product
Aging and Life Test Rack
SY2036
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
product
ST Fully-auto BDV Dielectric Oil Tester Set
Chongqing Assen Power Equipment Co., Ltd
ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
Control Transformers
Osborne’s Control Transformers are commonly used to step down primary circuit voltages to lower voltages to be used for control circuit applications. These units set the standard for premium, high performance, hand crafted control transformers. Your customers will appreciate your decision to work with the quality and reliability of Osborne Transformer’s control transformers.
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
Partial Discharge Test Set
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
product
Transformer Test Panel/ Setup
This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
-
product
Transformer Variable Radio Tester
WABC
Wuhan Sangao Electrical Test Installations Limit Co.
Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's s...show more -
product
Detection of PtG and PtP Faults on Multi and Single Core Cables
CableTroll 2350
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
product
Insulating Oil Dielectric Loss Tester
HDLT
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
product
Partial Discharge Monitor
doblePRIME PD-Guard
The doblePRIME PD-Guard continuously monitors partial discharge (PD) in equipment such as transformers, rotating machines, cables and switchgear.The doblePRIME PD-Guard provides local alarms and will communicate data and notifications across standard interface channels and through to networked supervisory systems. It analyzes RF emissions in the HF, VHF and lower UHF ranges.
-
product
Telecom Transformers
Our high-performance telecom transformers support multiple home phone line and power line network applications. These transformers have excellent THD performance, small footprints, and are designed to exceed industry standards. Single, dual, quad, six, octal and twelve transformer numbers are available.
-
product
Standard Current Transformers
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
904 Benchtop Six Phase 30A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.
-
product
Electronic AC Potential Standard
PMT25010
Power Measurement Technologies Inc.
Provides the electronic equivalent of a standard potential transformer as typically required for instrumentation potential transformer accuracy testing.
-
product
Potential Transformer Test Set
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
product
PC104 MIL1553A & MIL1553B Board
MS 1701
*Bus Interface - Standard ISA Bus (PC104 Interface)*One Dual Redundant MIL-STD-1553 Channels, Enhanced Mini-ACE BC/RT/MT Architecture*A periodic message insertion, Real-time bus playback with RT edit mode*Highly Autonomous Bus Controller Architecture, Message Scheduling*Bulk Data Transfers, Data Block Double Buffering*Asynchronous Messages, Retries and Bus Switching*Transformer or Direct Coupled 1553B Channels
-
product
Impulse Generators and Measurement Systems
Designed to generate impulse voltages that simulate lightning strokes andswitching surges as defined by IEC, ANSI/IEEE, and other national standards on:• Distribution transformers• Small power transformers• Cables (type tests)• Arrestors (impulse current tests)• Motors / generatorsTesting ApplicationsImpulse Generators andMeasurement Systems• Insulators• Bushings• GIS• Instrument transformers
-
product
Rectifier Assemblies for Crane Applications
CEHCO manufactures Transformer Rectifier Assemblies for Crane Applications. We offer standard products and customized solutions.
-
product
Voltage Transformer Testing System
KVTS
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
product
Force Tensiometers
Sigma 702ET
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
product
SF6 Decomposition Products Detector
JH4000A-4
Xiamen Jiahua Electrical Technology Co.,Ltd
JH4000A-4 SF6 Electrical Equipment Decomposition Products Detector is a high precision, intelligent and portable device, able to make judgment rapidly and correctly based on the content of main decomposition products of insulation materials inside the SF6 electrical equipment like SF6 circuit breaker, instrument transformer, GIS and transformer. It detects SO2+SOF2, H2S, CO and HF. It is reliable, accurate and stable. Inspected by authorities such as the National Institute of Metrology, the devi...show more -
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special confi...show more -
product
Instrument Transformer
CT & PT Test Equipment
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.