Filter Results By:

Products

Applications

Manufacturers

Showing results: 196 - 210 of 239 items found.

  • PXI 24 x DPST Reed Relays

    40-115-122 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • PXI 16 x SPST Reed Relay

    40-115-021 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • PXI RTD Simulator Module 6-Channel PT1000

    40-262-102 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel

    50-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel

    50-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • PXI RTD Simulator Module 12-Channel PT1000

    40-262-202 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 18-Channel PT1000

    40-262-002 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 6-Channel PT100

    40-262-101 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • Anti-Sulfurated Thick Film Type Resistors, Precision Type

    ERJ-U2R/ERJ-U3R/ERJ-U6R Series - Panasonic Industrial Devices Sales Company of America

    High Precision And High Resistance To Sulfurization In One Resistor!Panasonic's ERJ-U2R, ERJ-U3R, ERJ-U6R (ERJ-U*R Series) offers high precision and also provides anti-sulfurization characteristics that avoid an open circuit caused by a sulfide disconnection. High resistance to sulfurization is achieved through the use of an anti-sulfurated electrode structure and material in the manufacture of ERJ-U*R Series Resistors. AEC-Q200 Compliance and IEC 60115-8, JIS C 5201-8 and JEITA RC-2134C Reference Standards for the entire ERJ-U*R Series of High Precision, Thick Film Chip Resistors from Panasonic ensures optimal quality and reliability.

  • Gas & Flame Detection System

    Syntel - Teledyne Gas & Flame Detection

    Syntel is an addressable loop system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loo is fault tolerant operating normally with a short or open circuit. Syntel does not have a CPU, so there is no common failure point. It includes a standard OPC interface and can also be supplied by Modbus allowing easy integration with third party systems.Syntel stores alarm and calibration information in distributed non-volatile memory, hence there is no reliance on a centralized system.Syntel is ideal for installations where there is the possibility for future expansion. The system architecture allows very low cost expansion as cable runs to a central location are not needed.

  • GFCI and AC Circuit Analyzer

    Extech CT70 - Extech Instruments Corporation

    Circuit and wiring issues can introduce shock hazards and compromise performance of machinery and equipment. The CT70 is a GFCI and AC circuit analyzer which covers outlet load handling and outlet tester functions. AC load tester functions cover selectable loads of 12, 15, and 20 Amps; loaded and unloaded AC line voltage measurements; voltage drop/line impedance calculations; and peak line voltage. Outlet tester functions include neutral to ground voltage; hot, neutral, and ground impedance; GFCI trip time/trip current; and open or reversed wiring. The CT70 comes complete with AC test cord (standard North American 3-prong plug).

  • Transformer Variable Radio Tester

    WABC - Wuhan Sangao Electrical Test Installations Limit Co.

    Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's site using requirements , make the operation more convenient, complete function, stable and reliable data, the testing speed is greatly improved.To meet the needs of all kinds of small medium and large transformer ratio test.

  • Lan Cable Tester

    185 LCT - Standard Electric Works Co., Ltd

    ● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable.● The LAN cable tester can verify cable continuity, open, short circuit and miss-wired.● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan functions.● Ground wire test. ● Lock status function.● Buzzer sound warning for wire status.● Display : LED indication for wire status.

  • Open Path Combustible Gas Detector

    SafEye (Quasar 900) - Teledyne Gas & Flame Detection

    The Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.

  • Standard Helmholtz Coils

    Magnetic Instrumentation Inc.

    Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.

Get Help