Inductive Load Banks
See Also: Load Banks, AC Load Banks, DC Load Banks, Reactive Load Banks, Resistive Load Banks
-
Product
ELECTRIC BRAKE FORCE METER WITH DYNAMIC LOAD SIMULATION AND CIRCUIT TESTING
MDTT9107
-
*Tests truck-side brake controller output and all towing-lighting functions without a trailer*Displays real-time brake controller output gain and timing*Quickly troubleshoots electrical circuits and ground condition*For use with aftermarket and integrated brake controllers*Microprocessor controlled; simulates trailer brake loads*25' cable allows one-man, in-cab testing of brake controller and all truck-side tow circuits*Use to verify that the vehicle’s adaptive (speed/load sensitive) brake-controller output is functioning properly
-
Product
Programmable Single Channel DC Electronic Load, 150V/30A/200W
T3EL150302P
-
Programmable Single Channel DC Electronic Load, 150V/30A/200W.
-
Product
Single Point Load Cells
-
These have a range of different platform sizes and are suitable for different applications including bench scales, counting scales and other applications in many industries. Click the links below to find out more about each product and to view specific data sheets.
-
Product
Load Cabinet
DFX-20
-
• Working power: AC220V 50Hz • Normal load: Continuous adjustable from 0 to 280V • Electric current: 0~20A/Continuos adjustable cosφ: 0.3-0.96 under 16A; 0.6~0.96 more than 16A • Precision: 0.5 class, digital display • Counter: 0~999999 times, can be preset
-
Product
PXI MUX 2 Banks of 64 Channel 1 Pole
40-610-022-2/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
High Slew-Rate High Power DC Electronic Load (100A/μS)
34110A-11(10KW)
-
34000A Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.
-
Product
High Voltage DC Electronic Load
3360F Series(600W~14.4KW)
-
3360F has its own control and display panel, CC/CR/CV/CP/Dynamic modes, 150 sets Store/Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB, RS232,USB and LAN interface.
-
Product
THRU HOLE BARE AND LOADED BOARD TEST PROBES
SERIES 93
-
ElectricalMAXIMUM CURRENT: 7 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,35 mOHMS mean
-
Product
110V / 90 Amp Load
EL12-110M
-
For Telecom Rectifier and Power Supply testing. This particular Load has been designed to operate with Telecom 110V Rectifiers and Power Supplies with output Voltages in the range of 100V to 135V and is extremely cost effective.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-1000B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
Product
Load Cell Transmitter
MODEL SST-HV
-
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
Product
Digital 125 Amp Battery Load Tester
6033
-
• Heavy load enables the 6033 to detect bad batteries missed by other electronic testers• Automatically computes the CCA of the battery under load• Kelvin connected digital meter displays the following values:• Current Battery Voltage• Maximum Voltage reading• Minimum Voltage reading• Automatic load cycle• PATENTED• Made in USA of US and Global Components
-
Product
110V / 100 Amp Load
BD12-110P-48/24
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
Product
Digital Displacement Inductive Sensor
EX-V Series
-
High-speed, high-accuracy, digital inductive displacement sensors with sub-micron resolution and an ultra-fast 40,000 samples/sec. sampling rate. Automatic Bottom-dead-center measurement mode. High-speed sampling : 40,000 samples/second. Digital Inductive Displacement Sensor
-
Product
PXI MUX 2 Bank, 32 Channel Screened 1 Pole
40-610-021-S-2/32/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Button Load Cell
3000 Series
-
Button Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type provides a range of capacities up to 150 kN or 30 klb with better than ±0.5% (full scale) non-linearity. Three tapped holes are provided on the underside for ease of mounting. Fully welded cover, amplified and digitised versions are available on request.
-
Product
350W Bench Electronic Load, Single Input 150V, 60A, 350W
EL34143A
Load Module
Keysight’s EL30000 Series bench electronic loads consist of three models, all with a built-in data logger. The EL33133A basic performance electronic load offers an economical price, a limited range, and a single 40 A, 150 V, and 250 W input. Two performance models offer additional ranges, the EL34143A single input 60 A, 150 V, 350 W, and EL34243A dual input 60A, 150V, 600 W.
-
Product
Beam and Singlepoint Load Cells
-
We have trimmed all the non-essential fat off these load cells, however you can be sure that nothing has been trimmed from the actual load cells, they are precision tested and certified to meet all the exacting requirements on the downloadable technical specifications shown below.
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
Low Voltage High Current DC Electronic Load
N62400 Series
-
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
N62400 series is developed based on NGI's years of experience in testing for fuel cell. It is with high accuracy, high reliability and high cost-effective. N62400 series is with high power density and elegant appearance, which is available for benchtop use or installation in 19 inch cabinet.
-
Product
Electronic Load Board 3U CPCI-S (air cooled)
056-377
-
The 3U load boards are designed to simulate the power consumption of a single board computer and other boards on the backplane.
-
Product
Programmable DC Electronic Load
-
Programmable DC electronic load is a device that precisely regulates the load voltage and current dissipation power consumption of electrical energy. There are several important parameters to consider when choosing programmable DC electronic load, including maximum power, maximum current, maximum voltage, current slope, and so on. Each indicator is related to the needs and applications we actually test.
-
Product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 3 Ports
GPS312
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Thermocouple, Insert, Receiver, SIM, 8 Pos, 3 Slot (not loaded)
510180111
SIM Insert
Thermocouple, Insert, Receiver, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 310130113 Receiver, i2 MX, 22 Slot VTAC/SIM Insert, EMINot loaded. Thermocouple patchcords need to be purchased separately.
-
Product
Electronical Load Board 3U CompactPCI (air cooled)
045-097
-
The 3U load boards are designed to simulate the power consumption of a single board computer and other boards on the backplane.
-
Product
Electronic Load System
-
Electronic loads are required for testing fuel cells such as PEMFC, AFC, PAFC, MCFC, SOFC. These electronic loads are designed either in IGBT technology with power, current and voltage ranges according to specific requirements or in transistor technology. Electronic loads in IGBT technology are designed for high voltage ranges up to 900 V, current ranges up to 1000 A, and power ranges up to 480 kW.
-
Product
Unclamped Inductive Load Tester
ITC55100C
-
The system has been designed around a very powerful micro-controller that gives it a timing resolution of 40ns, twenty times faster than the previous model. Its response time to the peak and zero current is improved ten times. Combined this gives greater accuracy for the charging and avalanche times and for the reported peak drain current.





























