Thermocouple Loggers
Data Acquisition from thermocouples and data record of termperature events.
See Also: Temperature Loggers
-
Product
Pressure, Strain And Shock Data Loggers
-
Dataloggers for pressure, bridge input for strain or load measurement and also tri-axial shock dataloggers with built in accelerometers.
-
Product
Multi-Channel Programmable and Universal Input Data Loggers
-
These dataloggers have multiple channel inputs which can be universally configured to record temperature, process voltage/current, pulse, strain, etc.
-
Product
Multitrip Temperature Logger
TREX-8
-
The LogTag® TREX-8 is a versatile, wide range, multitrip Temperature Logger with interchangeable External Probes, featuring high resolution temperature readings over a measurement range of -40°C to +99°C (-40°F to +210°F).
-
Product
DC Voltage & Current Data Logger
-
The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. Simply plug the data logger into an available USB port on your PC and customize the settings or transfer data with the included Track-It Software program.
-
Product
Thermocouple, Contact, ITA, Alumel, Type K (°C)
610113134
Thermocouple Contact (ITA)
Primary mating contact 610113132.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
Product
Thermocouples
-
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
Product
K Thermocouple Air Probe
TP744
-
Thermocouple Type “K” air probe. Tolerance according to IEC 60584-2 standard.
-
Product
DataNet Wireless Data Loggers
-
The DataNet wireless system is a data acquisition solution developed for 24/7 real-time monitoring for mission critical organizations. Boasting a variety of wireless data logger models using ZigBee RF technology, the DataNet solution is capable of measuring parameters such as temperature, relative humidity, voltage, current, or frequency. Choose from DataNet models offering up to 6 inputs or the more cost-effective single or dual input Mini DataNet range, depending on your application requirements. Each DataNet mesh network is managed by a Receiver connected via USB to a Windows-based PC, and also supports addition of wireless Repeater units for extending the network transmission range and improving network robustness.
-
Product
Pocket-size temperature logger
DEFI2-T
-
DEFI2-T is a high-precision miniature water temperature recorder for long-term observations (approx. 573 days for 1 minute interval observation). The reduced size of the DEFI2-T allows the device to be installed in large numbers in a single mooring system, allowing investigating temperature fluctuations at increased spatial resolution. Also, AAA alkaline batteries used by DEFI2-T are easily available, reducing the operating costs.
-
Product
Eight-channel USB Voltage and Thermocouple DAQ
Model DI-2008
-
Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.
-
Product
Thermocouple Power Sensors
N8482B
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Thermocouple Vacuum Gauge Tubes
DV-6 Series for Medium Vacuum
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
Communication Data Logger
LE-270A
-
LE-270A is a Communication Data Logger, which records CAN/LIN communication logs in the SD/SDHC card for long hours. Using with a PC, it performs as a CAN/LIN protocol analyzer, and monitors data on the PC at real time (Line Monitor). Using without a PC, it performs as the CAN/LIN data logger, and saves data in the SD/SDHC card. It has two High-speed CAN transceivers, two Low-speed CAN transceivers and two LIN (TJA1020) transceivers. It monitors two channels of CAN or LIN, or one CAN and one LIN transceivers. In addition, four channels of Analog/Digital signals can be recorded.
-
Product
Wireless Data Logger
-
IM2100 Series Scanners are useful for scanning parameters like temperature, flow, humidity, pressure etc and indicate them in a multiplexed manner. These scanners show the values one after the other in preprogrammed time interval called scan time. Options like PC communication, alarm relays are available. Scanners can communicate with SCADA software and are suitable for Data Acquisition system where local recording is not required.
-
Product
K Thermocouple Immersion Probe
TP742
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
UniCAN 3 Data Logger
-
With up to 12 CAN bus interfaces, freely configurable digital inputs and outputs, Wake-on-CAN, LAN, WLAN - When developing the UniCAN 3 data logger, numerous requirements from state-of-the-art vehicle development were taken into account.
-
Product
Data Loggers
-
Are electronic devices which automatically monitor and record environmental parameters over time, allowing conditions to be measured, documented, analysed and validated.
-
Product
Modbus Data Logger
-
Mod Bus is a popular protocol that is used by manufacturers of instruments and sensors. Site instrumentation already exists and parameters to be recorded are available on Mod bus. We have in store fro our clients Mod bus Data Logger that can read data from these instruments and record them periodically. These loggers are configured as per the site requirements.
-
Product
12:1 IR Thermometer w/ K-Type Thermocouple Input
INF195C
-
UEi Test & Measurement Instruments
The INF195C offers the unique circular laser targeting showing users the exact spot being measured. This 12:1 Infrared Thermometer also offers advanced features including a wider temperature range, K-Type input, selectable emissivity levels, Min/Max, average, differential, a user adjustable alarm and backed by a 1-Year limited warranty.
-
Product
Thermocouple Kit
34307A
-
The Keysight 34307A is compatible with the Keysight 34970A Data Acquistion/Switch Unit. The 34307A can also be used with the Keysight 34401A, 34460A or 34461A, however, an external program is required to convert the voltage measurements to temperature and an ice bath or electronic reference junction must be used.
-
Product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
Temperature Logger for PT1000 Probe
TV-4204
-
PT1000 probes are available with this logger and will record down to -200C making them suitable for cryogenic applications. The probes are of 3-wire construction and available probes are listed in the 'You will also need' section.
-
Product
K Thermocouple Immersion Probe
TP656/1
-
“K” Type thermocouple imemrsion probe. Tolerance according to IEC 60584-2 standard. °C max: 1000. Response time: 1 s.
-
Product
Temperature Data Loggers
-
GAOTek offers a large collection of temperature data loggers that can adjust to any temperature measurement. There are different types of data loggers available in the market including food data loggers, environmental data loggers, and other specific work data loggers. Data loggers measure environmental temperature with the help of built-in sensors that can work in both hot and cold environment like the refrigerator, freezer, and ship containers. These devices are useful in work environments where temperature plays an important role like greenhouse industries.
-
Product
Data Loggers
-
Digital Readout Meter• 5-Decade, Auto Ranging• Stores 1000 Data Points• Supports GM, Proportional & Scintillator Detectors• Ratemeter/Scaler Modes• Supports 16 Detector Setups• DTC & Adjustable Window• RS-232 Port
-
Product
Stand-Alone, Humidity and Temperature Data Logger
RHTemp1000
-
The RHTemp1000 humidity and temperature data logger is a rugged, battery powered, stand alone device which can be used to automatically record humidity and temperature. This all in one compact, portable, easy to use device is able to measure and record data for up to 21,845 humidity and temperature measurements.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
K Thermocouple Immersion Probe
TP750
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.