Product
Diode Tester
FEC VF40CM
-
Frothingham Electronics Corporation
The VF40CM is intended for testing VF, HALF CYCLE SURGE, and THERMAL RESPONSE/RESISTANCE on small- and medium-power diodes and rectifiers. It can also measure THERMAL RESPONSE/RESISTANCE on NPN and PNP bipolar transistors using an external user-supplied VCB supply.The VF40CM also is sometimes used to measure VZ of low-voltage zener diodes up to the compliance voltage limit of the tester. 20V at 20A is possible.
-
Product
F Series Panel Meter
ST-90U
-
Standard Electric Works Co., Ltd
● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.
-
Product
M Series Panel Meters
ST-66
-
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
48V / 200 Amp Load
EL12-48M
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely costeffective.
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
M Series Panel Meters
ST-115
-
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting. Two studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
W Series Panel Meter
ST-100R
-
Standard Electric Works Co., Ltd
● Accuracy : Moving Coil Type DC, Class 2.0 Moving Iron Type AC, Class 2.5 Rectifier Type AC, Class 2.0● Case and Composition : Acrylic resin front and bakelite case. Bevel mounting.● Color : Black case and white scale plate.● Pointer Shape:Tube type, color in black or red
-
Product
Rectifier
-
An electrical device that converts alternating current, which periodically reverses direction, to direct current, which flows in only one direction.
-
Product
Signal Acquisition and Filtering Technology
SNAPTrack®
-
Built on a proven design, and with Pathfinder SAF Technology™ at its core, the SnapTRACK® offers RYCOM’s most advanced signal acquisition and filtering technology. The SnapTRACK® cable & pipe locator offers utility locators FrequencyFlex™ allowing users to adapt the system to their specific needs. Multiple active frequencies allow the user to accurately locate with a minimum of interference while maintaining the ability continue locating past faults and around conduit bends. Passive frequencies identify "live" and charged lines by their naturally occurring electromagnetic fields. The SnapTRACK® offers multiple passive frequencies -- 50Hz, 60Hz, Radio Frequency, Cathodic Protection Rectifier & CATV -- allowing line locating without the use of a transmitter.
-
Product
"Stiff Grid" and Parallel Operation AC Generator Excitation Regulator
SVRFP
-
The Kinetics model SVRFP Exciter/Regulator rectifier is designed and rated in capacity and operating parameters for the application of exciting the fields on an AC generator in parallel with other AC generators and the power system is a "stiff system" in relation to loading. A "stiff system" is a generating system that is of sufficient capacity or the generator is "small" in relation to the system grid, that the AC system voltage under impulse/step loading condition does not require forcing of the generator field to maintain the power grid voltage. Systems are designed with a standard unit service factor to operate within the +10% to -20% nominal voltage rating at 100% current rating.
-
Product
Schottky Mixer And Detector Diodes
-
Majority carrier diodes formed by plating a layer of metal on a layer of doped semiconductor, which forms a rectifying junction.
-
Product
LCL Filters
-
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
Product
M Series Panel Meters
ST-118
-
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
Earth Ground Meters
-
The earth tester determines ground resistance for both specific and ohm resistances. The earth tester is powered by batteries and have a clock timer function (3 minutes), Data-Hold function, a 3 ½ positions LCD display and their dimensions are 163 x 100 x 50 mm. Resistance ranges come from 20, 200 to 2000 ohms. They have a resolution of 10 / 100 mΩ / 1 Ω. The earth tester measure resistance by means of a constant reverse current (approx. 800 Hz, 2 mA). To measure ground voltage a rectifier is used (5 kΩ/V aprox. 40...500 Hz). The earth tester PKT-2630 series have a small format as well as multiple functions.
-
Product
AC-DC Rectifier Unit
-
Supreme Instrument Laboratories
Continuously variable/manually variable D.C. Rectifier unit to be used in the Electrical Engineering Laboratories, with the following technical specifications
-
Product
P Series Panel Meters
ST-70P
-
Standard Electric Works Co., Ltd
● DC up to 15A● AC up to 30A● Hz Meter : Measuring Ranges : 45~55 Hz, 45~65 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0● Case and Composition: Acrylic resin front. Bakelite case. ABS case. Four studs mounting.● Accuracy :DC : Class 2.0 AC : Class 2.5 Rectifier : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
DC Filter Inductors
-
Osborne DC filter inductors (aka filter chokes) are commonly used in AC to DC conversion circuits to present an inductive voltage drop to the AC component of rectified current. This inductive voltage drop acts as a filter. Osborne designs filter inductors to components to function effectively (without saturation) in the presence of the DC current. Osborne will work with you to mitigate the impact of ripple frequency in conversion circuits. Every Osborne DC filter choke is designed for high performance with special consideration given to your circuit´s power supply frequency and conversion configuration.
-
Product
Load Banks
EL08 Series
-
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.
-
Product
Industrial Standby Battery Monitoring Systems
-
Batteries are the power storage medium for all Power Rectifier and UPS Systems. Modern Rectifiers and UPS control systems generally supply the user with only a summary of the condition of the associated power systems, however Battery Monitoring systems specifically measure, record and analyse the individual cell and battery module parameters in detail.
-
Product
Independent Operation AC Generator Excitation Regulator
SVRi
-
Kinetics Control Systems SVRI Exciter/Regulator rectifier is designed and rated in capacity for the application of exciting the DC fields of an AC generator operating independently with other generators and/or NOT tied into a utility power grid.
-
Product
AC/DC Power Supplies
-
At ABSOPULSE Electronics, we specialize in the design and manufacture of heavy-duty custom and semi-custom AC-DC switching power supplies, rectifiers and battery chargers.We can meet any AC to DC input/output configuration requirement, with output power ranging from a few watts to several kilowatts.ABSOPULSE's rugged power supplies are typically designed and built for an operational life of 20 to 30 years in harsh environments.
-
Product
Portable Current Supply 10 AMP output
CS-10
-
The CS-10, Sure beats carrying around a rectifier and generator...
-
Product
AC Ammeters And Voltmeters With A MuP Type Rectifier
-
*AC Ammeters and voltmeters with rectifier type MuP 40,80,210,220,230*Handle deflection 85 ° type MuP40, MP 80*Handle deflection of 100 ° type MuP210, MuP 220 / 220T, MuP 230 / 230T*The technical data catalog can be found on the download tab below the product.
-
Product
4kW Electronic Load
PT04-110
-
For Telecom Rectifier and Power Supply testing. This model has been developed to accommodate testing of both 110V and 48V telecommunications power systems or Power Supplies. It is also useful as a general-purpose variable Load. Its founding principle is simplicity – ease of use, enhanced reliability, greater value for money and wider applicability.
-
Product
AC and DC Electronic load
63800 series
-
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing thereby giving reliable and unbiased test results. The 63800's state of the art design uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability. Comprehensive measurements allow users to monitor the output performance of the UUT. Additionally, voltage & current signals can be routed to an oscilloscope through analog outputs. The instrument's GPIB/RS232 interface options provide remote control & monitor for system integration. Built-in digital outputs may also be used to control external relays for short circuit (crowbar) testing.
-
Product
Bridge Rectifier Diodes
-
ST’s portfolio of bridge rectifier diodes is intended for primary bridges. In input primary bridge applications, ST's 1200V bridge diodes achieve very low conduction losses thanks to very low forward voltage characteristics. They can operate at up to +175 °C junction temperature, as a result of reduced leakage currents. Bridge rectifier diodes are belonging to the STPOWER family.
-
Product
Hall Effect Proximity Switches/Sensors
-
ChenYang Technologies GmbH & Co. KG
A Hall Effect proximity switch is a non-contact electronic switch, which consist of a permanent magnet or ferromagnetic part as trigger intermediary and a Hall Effect sensor IC. The Hall sensor IC detects the change of the magnet field when the permanent magnet comes in the close proximity to it and generates an electric signal. This signal is amplified and rectified to control the output signal of the switch.
-
Product
Power Discrete Tester
Mostrak-2
-
M2 test system has multiple test generators which cover static and dynamic test procedures. It is our first truly modular tester which allows for the system to be upgraded and expanded when needed. M2 are designed to get the tester as close as possible to the handler interface and operator at the highest possible speeds. M2 is capable of HV (3 kV) and LV (600A) testing and has dynamic switching capabilities up to 1200V. MOSTRAK systems can test the following device types: MOSFET, IGBT, Bipolar transistor, Diode - rectifiers, Thyristor (SCR) - Triac, Linear voltage regulator (VReg), Transient voltage suppressor (TVS).
-
Product
"Soft Grid" and Parallel Operation AC Generator Excitation Regulator
svrsp
-
The Kinetics model SVRSP Exciter/Regulator rectifier is designed and rated in capacity and operating parameters for the application of exciting the DC fields on an AC generator operating in parallel with other AC generators and the power system is a "soft system" in relation to loading. A "soft system" is a generating system that may not be able to sustain the rated AC voltage under impulse/step loading conditions and results in voltage reduction when tan impulse/step load is applied.
-
Product
High Voltage EMC Surge Generator
TM510
-
TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.