Showing results: 526 - 540 of 1012 items found.
-
40-670C-021-10/8 -
Pickering Interfaces Ltd.
The 40-670C-021-10/8 is a 10-channel, 8-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Test Spectrum, Inc.
The test engineering staff at Test Spectrum has developed hundreds of test software projects on all major ATE platforms for numerous product technologies.Whether you need to optimize a current test platform, convert to a lower cost test platform, or design a brand new program for a cutting edge product within incredible time constraints, the Test Spectrum team will exceed your program expectations with quality products and excellent results.
-
40-670C-021-49/2 -
Pickering Interfaces Ltd.
The 40-670C-021-49/2 is a 49-channel, 2-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-675A-002-49/4 -
Pickering Interfaces Ltd.
The 40-675A-002-49/4 is a 49-channel, 4-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-670C-022-99/2 -
Pickering Interfaces Ltd.
The 40-670C-022-99/2 is a 99-channel, 2-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-670C-022-10/16 -
Pickering Interfaces Ltd.
The 40-670C-022-10/16 is a 10-channel, 16-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-675A-002-99/2 -
Pickering Interfaces Ltd.
The 40-675A-002-99/2 is a 99-channel, 2-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675A-002-198/1 -
Pickering Interfaces Ltd.
The 40-675A-002-198/1 is a 198-channel, 1-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
NI
PXI instrumentation ensures complete and accurate test coverage with a modular architecture mounted in ultra-reliable PXI chassis.TestStand and LabVIEW software provide rapid development of complex test steps and sequences. PXI systems conserve floorspace because of their small, light form factor. Order them preassembled and installed using NI ATE Core Configurations.SystemLink™ software deploys updates and democratizes data insights to optimize operational efficiency.
-
45-542-001 -
Pickering Interfaces Ltd.
The 6U PXIMatrix Module 45-542 is a very high density electro-mechanical relay matrix available in 132x8 format with 1 pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability 2A electro-mechanical relays, offering >10e8 operations (under low power loads) to give maximum switching confidence with long life and stable contact resistance.
-
SASI -
Textron Systems
Textron Systems’ SASI 240 is a Signal Analysis Synthetic Instrument that combines the capabilities of six distinct measurement systems into a single device. Our dual-channel architecture enables two independent radio frequency (RF) measurements to be run simultaneously. Whether used as a benchtop device or an integrated automated test equipment (ATE) RF subsystem, our SASI’s simple and intuitive graphical user interface (GUI) ensures easy, out-of-the box functionality.
-
40-675-002-99/2 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675-002-198/1 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675-002-49/4 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
40-675-002-24/8 -
Pickering Interfaces Ltd.
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.