Showing results: 61 - 75 of 377 items found.
-
Hirst Magnetic Instruments Ltd
is a magnetic field sensor that passes electrical current when the sensor is perpendicular to a magnetic field. The stronger the B-Field, the more current it passes. Pira DCS # 5M10.10.
-
MagCam NV
Magcam's MiniCube1Dmagnetic field camera provides quantitativeBz magnetic field mapping in a 12.7mm x 12.7mm 2D planewith 0.1mm spatial resolution, measured at high speed. The camera is based on Magcam's unique integrated 2D Hall sensor array technology, featuring more than 16000 microscopic magnetic field sensors on one single chip. Each sensor independently measures the local magnetic field, resulting in quantitative2D magnetic field maps with high spatial resolution, measured athigh speed. These magnetic field maps contain a large amount of information about the magnet's properties, which can be extracted using Magcam's powerful MagScope measurement and analysis software.
-
Beehive Electronics LLC
The Beehive Electronics 135A RF Helmholtz coil generates a well-controlled, uniform magnetic field. It can be used to calibrate magnetic field probes, such as the Beehive 100 series, or for testing the susceptibility of other devices to magnetic fields. The Helmholtz coil comes supplied with a fixture that makes it easy to calibrate Beehive 100 series probes.
-
RF6 set -
Langer EMV-Technik GmbH
The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
300 Series -
Integrity Design and Reseach Corp.
Typical Applications include Measurements of the Earth's field vectors, Air shipment inspection, Mapping and recording field perturbations, Magnet classification, Analysis of magnetic circuitry and components, Magnetic Resonance Imaging (MRI) and Measuring residual fields.
-
BW-MST-E5000 -
B&W Engineering Corp.
The Mechanical Shock Tower develops the kinetic energy electromagnetically. An iron core "bullet" is attracted to the magnetic core of the solenoid by the dense magnetic field that is created as current flows through the field coil of the shock tower. As the bullet is drawn into the center of the magnetic field the acceleration increases exponentially as the gap reduces to zero on impact causing the high impact shock
-
Renishaw Inc.
The magnetic encoder detects rotational position information as changes of the magnetic field, converts them into electrical signals, and outputs them. The simplest magnetic encoder consists of a permanent magnet and a magnetic sensor.
-
DX-160 -
Dexing Magnet Tech. Co., Ltd
DX-160 Full-digital high-precision gaussmeter/teslameter is designed for high-test precision, high-resolution magnetic field test applications. It provides a wide-range measurement from DC to up to 50kHz AC magnetic field measurement.
-
Ferrites India
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
EM-6873 | 20 Hz – 100 KHz -
Electro-Metrics Corp.
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
-
-
Promis 10 -
IRIS Instruments
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
Inertial Labs, Inc.
The professional model of INS, the INS-P utilizes an embedded, high-precision, gyro-compensated magnetic compass, what allows the navigation system to measure and output high precision Heading without GNSS signal even in extreme environmental conditions (temperature, vibration, interference from external magnetic field).magnetic field).
-
Smart Parking -
Libelium Comunicaciones Distribuidas S.L
The main method is magnetic detection: a 3-axis magnetic sensor reads the variations in the Earth's magnetic field. The big mass of metal of a car parked on the slot changes this field and the node will know. The software inside the node implements advanced algorithms to dynamically compensate the temperature variations and also the influence of neighbor cars.