Filter Results By:

Products

Applications

Manufacturers

Luminance

The photometric measure of luminous power.


Showing results: 46 - 60 of 63 items found.

  • Spectroradiometer

    SR-Series - RayClouds Photoelectric Technology Co.,Ltd.

    SR-Series Spectroradiometer is equipped with resolution detectors of different pixel levels, particularly adding a spectroscopic measurement mode, which provides optional specific wavelength intervals for data analysis of the measured luminance, chrominance, color temperature, spectroscopy, etc. Cooperated with ProICM professional analysis software, it can perform high-speed and high-precision measurement of micro luminous surfaces, and provides a new and practical optimization scheme of two-dimensional spectroscopic test.

  • Smart G-Scope

    Dou Yee Enterprises (S) Pte Ltd

    Auto focus digital microscope & telescopeReal fast auto focus by using liquid lensInfinity(x10) ~ Contact (x250) hole area auto focus by changing mode switchAuto focus & manual focus functionChangeable various End caps to support 3pi coner end capHigh luminance OLED displayInfrared wireless controlSupport Android & Windows (XP, Win 7, Win 8)Various image filters & digital zoom functionSpecial design for portablility (aluminum case) No battery neededProvide software for Android and PC

  • Isolation Amplifier Analog Output

    Renesas Electronics Corp.

    This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a high-accuracy D/A converter on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.

  • Goniophotometer

    PIMACS CO., LTD.

    A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.

  • LCD Display Optical Measurement System

    RayClouds Photoelectric Technology Co.,Ltd.

    LCD display optical characteristics automatic measurement system is mainly used in LCD, LED screen, OLED screen, FPD, Mini LED, Micro LED and various new luminous materials.LCD display optical characteristic automatic measurement system supports the test of optical performance parameters such as viewing angle, luminance, uniformity, contrast, chrominance, response time, flicker, and refresh rate, etc.

  • Isolation Amplifier Digital Output

    Renesas Electronics Corp.

    This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a digital signal (MDAT, MCLK) output function on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.

  • Imaging Colorimeters

    Westboro Photonics

    Westboro Photonics offers high resolution, high performance imaging colorimeters to meet the needs of manufacturers for several key applications: Computer and cell phone keyboards: automatic measurement, identification and pass/fail analysis for luminance and chromaticity of backlit glyphs and other lit elements. Beam pattern analysis of the luminous intensity distribution of lamps and LEDs. Avionic light plate panel balancing. Transportation, architectural and municipal lighting and signage.

  • Optical Meters

    Gamma Scientific Inc.

    The Gamma Scientific range of light meters includes handheld and benchtop models.  Configuration options include a wide range of sensors and calibrations in units including:  Luminous Flux (lumens) or Radiant Flux (Watts),  Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr),  Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr),  or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.

  • Virtual Display Analyzer

    V-Series - RayClouds Photoelectric Technology Co.,Ltd.

    V-Series Virtual Display Analyzer is equipped with high pixel and high resolution detector and detection lens simulating human eye, cooperated with ProICM professional analysis software to analyze the optical characteristics of ARVR equipments. It can accurately detect optical parameters such as luminance, chrominance, contrast, MTF, FOV, image distortion, Cross Talk, ghosting, etc. of the image and quickly output the results of the measured parameters, providing a perfect product testing scheme to carry out strict quality control of ARVR products. ContactContact

  • Instrumented Runway Visual Range Transmissometer System

    AGIVIS 2000 - Aeronautical & General Instruments Ltd.

    AGIVIS 2000 is a transmissometer-based Runway Visual Range (RVR) system that provides the highest possible levels of accuracy. The first generation of AGI RVR systems were developed in co-operation with the UK Met Office and CAA, and AGI has been supplying RVR systems for more than 25 years. AGIVIS 2000 systems are currently operational at major international airports certified for instrument landings up to and including CAT IIIB. AGIVIS 2000 is fully compliant with ICAO, WMO and CAA requirements. The system consists of transmissometer field sites, background luminance meters, runway lighting interfaces, data processing equipment and archive storage and backup. It can drive multiple full-colour dedicated RVR displays. Systems can be supplied fully installed with comprehensive engineering and operator training, and post-installation support is available worldwide.

  • Regenerative AC Load

    61800 - Chroma ATE Inc.

    Chroma Power Electronics Test Solutions not only apply in the industries of Information Technology, Communication, Aerospace and National Defense, but also in energy efficient products such as Hybrid Automobiles, LED luminance devices, solar and fuel cells that are developed aggressively under the pressure of natural resource constraints. Chroma has a wide variety of instrumentation including AC Power Sources, DC Power Supplies, DC Electronic Loads, AC Electronic Loads, Digital Power Meters, and Automatic Test Systems that are ideal for power input/output terminal tests and dynamic simulation.

  • Power Electronics Test Solutions

    Chroma ATE Inc.

    Chroma Power Electronics Test Solutions not only apply in the industries of Information Technology, Communication, Aerospace and National Defense, but also in energy efficient products such as Hybrid Automobiles, LED luminance devices, solar and fuel cells that are developed aggressively under the pressure of natural resource constraints. Chroma has a wide variety of instrumentation including AC Power Sources, DC Power Supplies, DC Electronic Loads, AC Electronic Loads, Digital Power Meters, and Automatic Test Systems that are ideal for power input/output terminal tests and dynamic simulation.

  • Instrument Systems LED And Display Measurement

    Konica Minolta Sensing Americas, Inc

    Instrument Systems is a frontrunner in developing state-of-the-art light measurement equipment, software, and accessories, taking great pride in constructing products that provide fast, accurate readings to ensure precise data for laboratory, production and quality assurance testing. All Instrument Systems products have stringent quality and performance requirements to ensure that customers get the highest quality equipment. As a leading supplier world-wide, they provide cost-sensitive support to a diverse clientele to help them measure luminance, flux, intensity, illuminance, and chromaticity of LEDS, lamps and displays throughout all aspects of product development and production.

  • Spectrometer & Colorimeter

    PIMACS CO., LTD.

    Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.

  • Light Sources

    Inframet

    There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:

Get Help