Electric Field Probes
measure E and H fields from KHz to GHz.
See Also: Electrical Field, Electric Field
-
product
BPLT-1 Long Travel Bead Probes
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50D
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
Non Replaceable General Purpose Probe
MEP-20
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
product
Field Strength Receiver
KH3933
Beijing KeHuan Century EMC Technology Co,.LTD
KH3933 is a fully automatic interference field strength receiver integrating antenna and receiver. It is an important equipment for space field strength testing. It can be used to measure useless or harmful related radio interference signals in space, as well as medium wave and short wave. The field strength of the radio signal from a radio station. When measuring radio interference signals, this machine complies with GB/15707-1995 , DL/T691-1999 , and is suitable for high-voltage transmission lines and substation radio interference signals. This receiver complies with CISPR16-1 and GB6113-1 manufacturing standards.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1L-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3D-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Magnetic Field Sensor
Vernier Software & Technology, LLC
The Magnetic Field Sensor can be used to study the field around permanent magnets, coils, and electrical devices. It features a rotating sensor tip to measure both transverse and longitudinal magnetic fields.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25B-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1I-10
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Near Field Probes
Used for accompanying measurements of high-frequency, electric and magnetic RF fields on assemblies and devices.
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Field Strength Calibration Probe
Beijing KeHuan Century EMC Technology Co,.LTD
Three-axis omnidirectional 100kHz~6GHz light transmission.
-
product
HPA-50 General Purpose Probes
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
High 1.50 (43.00) - 9.60 (272.00) Long Travel Bead Probe
BPLT-1C-9.6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25A-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Electrical Calibration
Process Instruments calibrates a wide variety of test and measurement equipment. All calibration procedures are written, and most are automated, insuring reliability and repeatability of measurements.
-
product
E-S General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Universal Field Calibrater
UFC 45-B
Model UFC-45-B field calibrater is widely used calibration tool in process industry for last 15 years. Functionally it is designed to tackle most common trouble-shooting during commissioning and routine maintenance. Model UFC-45-B is truly hand held calibration instrument purposely limited functionally to simplify its use. With all its features UFC-45-B battery operated field calibrator is an essential tool in a service engineers kit.
-
product
Godzilla High Current Probe, 100 Amp
HC375
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Probes, Magnetic Field
EM-6880 | 9 KHz – 520 KHz
The EM-6880, EM-6881 and EM-6882 Magnetic Field Probes operate in conjunction with any 50 ohm input impedance receivers.
-
product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-3
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Ultra High 3.83 (109.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-72I-10
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,700Overall Length (mm): 43.18





























