Filter Results By:

Products

Applications

Manufacturers

NO2

Nitrogen Dioxide

See Also: Oxygen


Showing results: 16 - 30 of 37 items found.

  • Dynamic Dilution Calibrator

    Model T700 - Teledyne Advanced Pollution Instrumentation

    The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.

  • Trace-Level Dilution Calibrator

    Model T700U - Teledyne Advanced Pollution Instrumentation

    The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Chemiluminescence NH3 Analyzer

    ​Model T201 - Teledyne Advanced Pollution Instrumentation

    The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.

  • Gas & Emissions Analyzer

    Si-CA 8500 - Sauermann Group

    Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.

  • Continuous Emissions Monitoring

    atmosFIR CEM - Protea Ltd

    atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software.

  • Zero Air System

    ​Model N701 - Teledyne Advanced Pollution Instrumentation

    The N701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also simultaneously be used as a pressure source for activating instrument pneumatic valves and/or purge air for permeation tube ovens. The N701 includes a dewpoint sensor, an oil-less and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. An optional high performance heated converter is available for effective removal of Carbon Monoxide (CO) and Hydrocarbon gases.

  • Indoor Air Quality Monitoring

    Si-AQ VOC Monitor - Sauermann Group

    The SI-AQ VOC Monitor is the ideal instrument for you should your specific application require testing for Volatile Organic Compounds (VOCs) or potentially harmful gasses such as Carbon Monoxide (CO). In addition, the (Si-VOC) Si-AQ VOC Monitor can an also be outfitted with up to three (3) Gases sensors in total among VOC, CO2, CO, Formaldehyde, NO2, NO, O2, SO2 & H2S in addition to measuring Relative Humidity, Ambient Temperature and Barometric Pressure.

  • High Range Chemiluminescence Oxides of Nitrogen Analyzer

    Model T200H - Teledyne Monitor Labs

    The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200H comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • ​Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer

    Model T200M - Teledyne Monitor Labs

    The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 ​​converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.​

  • ​​​​Nitrogen Compounds Analyzers

    Teledyne Monitor Labs

    TML produces a wide range of analyzers for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series analyzers offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our analyzers are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.

  • Nitrogen Compound Instruments

    Teledyne Advanced Pollution Instrumentation

    Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring

  • Sensor Solutions for IoT

    imec

    Imec is a reference in the design of ultra-low power electronics, low-power algorithms to increase intelligence and data security, and in all aspects of data science. Our multi-sensor environmental monitoring platform features sensors for temperature, relative humidity, NO2, CO2, VOC (volatile organic compounds), particle matter, ambient light, sound, vibrations and presence detection. Our test platform is suitable for indoor and outdoor air quality monitoring and control, and can be used in smart buildings, smart cities and more.

  • Full Parameter Monitoring System

    CEMS-2000B FT - Focused Photonics Inc.

    CEMS-2000 B FT system uses direct thermal wet extraction method based on FTIR gas analysis technology, the system mainly has three major components: sampling pre-process-ing system, FTIR gas analyzer,and data acquisition and processing unit. The system can simultaneously monitor multiple groups of components in flue gas such as SO, NO, NO2, NOx, NH3, HCL, HF, O2, CO, CO2, CH4, H2O, etc. It is especially suitable for waste incineration.

  • On-board Emissions Measurement System

    OBS-ONE GS Unit - HORIBA, Ltd.

    OBS-ONE is the latest Portable Emissions Measurement System designed for engine/vehicle certification under real road conditions.It measures concentrations of emissions (CO, CO2, THC, NOx, NO2), particulate matter, air-to-fuel ratio, exhaust flow rate, GPS data, environmental conditions (atmospheric temperature, humidity and pressure) and calculates mass emissions.OBS-ONE features the highly adaptable, intelligent operating platform called “HORIBA ONE PLATFORM” which integrates other ONE series product data and optimizes test cell operation.

Get Help