  • Hazardous Location Syringe Pump

    500HLf - Teledyne LABS

    The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    260HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Integrated Gas Alarm & Control System

    MCX-32 - Teledyne Gas & Flame Detection

    The MCX-32 controller features a flexible design that allows the user to customize a system by choosing from a selection of individually addressable field devices or use addressable input and output modules. Detcon’s full range of gas sensors (purchased separately) can be used to create a gas detection system consisting of toxic gas, combustible gas, and/or oxygen deficiency. A wide range of field devices such as liquid level, temperature, pressure, flow, etc., can also be configured for input to the control system. Four standard I/O modules are available: a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). I/O modules are din-rail mounted and stackable allowing for seamless system expansion. The I/O modules may be mounted within the main system enclosure or in separate enclosures suitable for the area classification where installation will occur. In many cases using distributed I/O nodes can significantly reduce wiring and installation costs.

  • Salt Spraying Test Chamber

    Sanwood Environmental Chambers Co ., Ltd.

    Sanwood is glad to be the ODM/OEM manufacturer of Salt Spraying Chamber,Salt Spray Test Chamber,salt spraying test chamber,Salt spraying chamber,Salt spraying chamber sales enterprises all over the world! 1:It adopts 5mm or 8mm imported gray and white impact resistant P.V.C board, with high temperature resistance up to 85℃ and corrosion resistance. 2:Support frame: ¢ 10MM fiberglass rod, corrosion resistant. The steel V-frame and the fiber rod angle are placed to ensure the specimen is inclined at 15-30 degrees. 3:Pressure barrel is welded seamlessly with 2.0MMSUS304 stainless steel plate 4:The heating adopts titanium alloy electric heating tube. It has high corrosion resistance and long service life is 3-5 years higher than ordinary stainless steel heating tube. 5:The cover is made of 5MM imported transparent (Germany YLIS) acrylic sheet. It has fine workmanship, beautiful appearance and high transparency.

  • Rack Mounted Load Banks

    Junxy Energy

    Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.

  • MOTUS Stand-Alone Sensor

    Aanderaa Data Instruments AS

    There are numerous ways of measuring Ocean Waves. At Aanderaa, we focus on three measurement types: pressure, acoustic, and motion. In this section, we cover the motion-based sensors in the MOTUS family.MOTUS Directional Wave Sensor is suitable for integration on different buoy types. It is intended for commercial as well as research use. The directional stand-alone Sensor processes wave data and is configurable to directly present parameters and wave spectrum. The sensor can be connected to a SmartGuard using the CANbus-based AiCaP protocol. It can also be connected to a PC or third-party systems through the RS-232 interface.MOTUS Wave Height Sensor is for wave height only. As the MOTUS Directional Sensor, it is suitable for integration on different buoy types. In the sensor, the directional wave parameters are locked. It is possible to open the wave direction parameters with a software license from Aanderaa later if the need changes. MOTUS Lite OEM Sensor is the OEM version of the MOTUS Directional Wave sensor. It is delivered as an electronic board without housing and cables. Please get in touch with the factory for more options and restrictions.

  • Noise Sensor

    CRY2301 - CRYSOUND

    CRY2301 Noise sensor is a new type of noise test equipment independently developed by CRY Sound for industrial grade applications. It can realize real-time noise time domain and frequency domain analysis with real-time spectrum analysis software. The product complies with such standards as IEC61672 (Class 1) and GB/T3785 (Class 1). CRY2301 integrates measurement microphone, preamplifier, data acquisition, and data communication in a compact structure. It supports an optional 1'' high-sensitivity microphone for extremely low sound pressure testing. CRY2301 uses a USB interface for data communication and power supply. As a composite USB device consisting of a USB Audio device and a HID device, it is compatible with 32-bit/64-bit Windows 7 and Windows 10 systems. CRY2301 is equipped with real-time spectrum analysis software for easy access to time and frequency domain measurements. The real-time spectrum analysis software supports frequency weighting and time weighting, and can perform acoustic analysis, such as noise statistical analysis, octave analysis, and FFT analysis.

  • Frequency Conversion Rotating Magnetic Fla

    MT-2XCF - Mitech Co., LTD.

    MITECH MT-2XCF rechargeable frequency conversion rotating magnetic flaw detector is based on principle that the leakage magnetic field can absorb the magnetic powder. Make use of magnetic yoke magnetized the workpiece of ferromagnetic material. If there has defects it will produce leakage magnetic field that will adsorb magnetic powder. We could detect the flaw by observing the density of adsorption magnetic powder. It adopts large capacity lithium battery. By the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 6 hours. And the battery can be charged when the detector is on and off. Especially suitable for the field testing. It can choose the current frequency according to the flaw depth with unique frequency conversion communication design, that improve the detection sensitivity. It’s widely used in aircraft manufacturing, boiler and pressure vessels and other fields. It is a necessary professional precision instrument of quality control, in-service safety monitoring and life assessment.

  • Handheld Water Quality Meters

    LAQUA PD210 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • Thermocouple Vacuum Gauge for High Vacuum

    DV-5 Series - Teledyne Hastings Instruments

    ​Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-5 series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-5, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-18 reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters!

  • Vacuum Sensor, Thermocouple Vacuum Gauge for High Vacuum

    DV-5 Series - Teledyne Hastings Instruments

    ​Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-5 series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-5, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-18 reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters!

  • Domestic Direct Reading Spectrometer

    CS-8610 - Wuxi Tianmu Instrument Technology Co., Ltd.

    1. Convenient, practical and reliable: unique combustion device, equipped with infrared detection system, direct connection, remote control operation.2 , patented burner design (using utility model patent technology)The burner electrode upgrading system adopts a spring structure, the electrode adjustment is convenient, and the double sealing ring guarantee the pressure balance in the furnace cavity without tempering.3 , to ensure accurate measurement results◆Using low-noise, high-sensitivity, high-stability pyroelectric infrared detectors.◆Specially-made new platinum infrared light source, continuous heating and high spectral efficiency.The modular design of the whole machine, the electronic circuit is highly integrated, which improves the reliability of the instrument.◆Industrial-grade integrated linear module power supply, stable output, no fault.◆The infrared detection part and the combustion furnace are connected by optical fiber, and cooperate with multi-level concealed isolation circuit to completely eliminate arc interference.◆Double filter device to reduce the impact of dust on the analysis results.4 , electronic balance is not quantitative sample: you can choose different brands of electronic balance, automatic online, to achieve non-quantitative weighing.

  • Portable Analyzers

    Alpha Moisture Systems

    The key to the operation of Alpha Moisture Systems' Portable Analysers is the unique Desiccant Dry-Down Chamber. By keeping the sensor dry between tests, the special assembly of the head ensures that the instrument is always ready for immediate use. The head assembly consists of two chambers which have a telescopic action. When the head assembly is in the 'closed' or 'Dry-Down' position, the sensor is completely surrounded by desiccant, which absorbs the remaining water moisture from the sensor and hence it is dry and ready for use. The small space at the bottom of the test chamber enables the sample pipe to be purged before the test commences without wetting the sensor. By placing a finger over the outlet of the head, the sample pressure is able to open the test chamber automatically, exposing the sensor to the gas being tested and enabling accurate reading of moisture content in the sample gas. After each test the head assembly is closed by depressing the inner section so that the sensor will again be dried by the desiccant, leaving the sensor ready for use time and time again. The desiccant is kept in the inner chamber and is not exposed to ambient room air or the sample gas, therefore there is no need for frequent regeneration or replacement of the desiccant.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • Portable Hand Held Load Cell Indicator

    MODEL SSI - Transducer Techniques, Inc

    The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a Units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak and/or valley testing capability. Auto-tare allows the meter to be set to zero for any input signal level. The SSI also features a USB port for data logging to a PC. You can also log data to the SSI’s internal memory storing up to 16,000 time and date stamped readings. The SSI also features 2 built-in solid-state alarm relays with LED and audible indicators. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications where the SSI is mounted permanently.