Ground Fault
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
Ground Fault Monitor
IFT-120
Our ground fault monitors enable you to easily and quickly find the source of the fault before a major problem occurs and damages your equipment. This is the IFT-120, designed to assist you in rapid identification of ground faults.
-
product
Ground Fault Detectors
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
product
Ground-Fault Products for Solidly Grounded Systems
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
product
Ground Fault Locator
K-800
Kongter Test & Measurement Co., Limited
Kongter’s K-800 Ground Fault Locator is the new model which is developed to fast detect, trace and pinpoint virtual ground faults in LIVE DC systems where electrical cables have breakage with current lost to ground.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Handheld Grounding Tester
HGT1
The HGT1 is a handheld meter to measure ground impedance as well as step and touch voltages. Using the CPC 100 and CP CU1, test currents at variable frequencies can be fed into power cables or overhead lines safely to simulate a ground fault.
-
product
Stator Ground Protection Relay
SEL-2664S
Schweitzer Engineering Laboratories, Inc.
Protect high-impedance grounded generators from ground faults at standstill, during startup, and while running with the multisine frequency injection and neutral overvoltage-based protection in the SEL-2664S.
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
product
DC Earth Fault Locator
GFL-T + GFL-R
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Multi-Channel Telemetry
The AT7000 multi-channel systems can combine any customized mix of ordinary sensors: strain gages, thermocouples, RTDs, accelerometers, as well as motor/generator field voltages, currents and ground fault currents. The received data is continuously streamed to the user as analog (+/- 10V or 4/20mA) or digital data.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
product
Ground-Fault Location Products for Ungrounded Systems
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Socket Tester
1945
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
product
Relays, Switches, Sensors
CR Magnetics Sensing Relays and Switches provide a simple method of monitoring electrical properties and alerting a system to a fault or event condition. These products are available with a wide variety of configurations, including time delays, various output styles and logic. From simple proving switches, to fully featured high performance ground fault sensing.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Variable Power Supply
VS-10a
The VS-10a power supply is a light weight, portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 10 amps, thus the name VS-10a. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-10a is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case.
-
product
High Impedance Differential Module
HID
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.