Ground Fault
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Ground Fault Locator
K-800
Kongter Test & Measurement Co., Limited
Kongter’s K-800 Ground Fault Locator is the new model which is developed to fast detect, trace and pinpoint virtual ground faults in LIVE DC systems where electrical cables have breakage with current lost to ground.
-
product
Ground Fault Monitor
IFT-120
Our ground fault monitors enable you to easily and quickly find the source of the fault before a major problem occurs and damages your equipment. This is the IFT-120, designed to assist you in rapid identification of ground faults.
-
product
Ground Fault Locator
GFL-1000
The GFL-1000 ground fault locator is used to pinpoint faulty grounding where electrical cables have breakage and lost to the ground. The GFL-1000 is recommended by NERC PRC-005-2 to inspect for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. Included software allows for data management analysis.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Ground-Fault Products for Solidly Grounded Systems
Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.
-
product
Portable Testing
Whether you need handheld testers, digital hydrometers, ground fault detectors or discharge testing equipment, we offer the cutting-edge technology you need to stay ahead in managing and maintaining your power systems.
-
product
DC Earth Fault Locator
GFL-T + GFL-R
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
product
Stator Ground Protection Relay
SEL-2664S
Schweitzer Engineering Laboratories, Inc.
Protect high-impedance grounded generators from ground faults at standstill, during startup, and while running with the multisine frequency injection and neutral overvoltage-based protection in the SEL-2664S.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Battery Ground Detector
BGD
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
product
Voltage-Pen-Detector
Are a relatively simple testing instrument that enables electricians and other uses tolocate, trace and identify common electrical problems. These testers can locate wires behind walls, underground,and inside junction boxes. Others are designed to find blown fuses or test light fixtures. Some testers can evenlocate neutrals, ground faults, and high voltage lines without interrupting power
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
product
Protection Relays
Electrical protection relays for high voltage & high current protection offer protection in traction equipment as well as railway infastructure. Protection relays are used for applications like catenary voltage, short circuit, overload and ground fault detection in traction power electronics or railway substations.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
E-Z Check® Plus GFCI Circuit Tester
61-051
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCI*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
Fault Locator
VM-510FFL+
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
product
E-Z Check® Circuit Tester
61-035
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCIs*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty