Current Injection
-
Product
Brute High Current Probe
P4301-1Z
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
NI-9207, 500 S/s, 16-Channel C Series Voltage and Current Input Module
781068-01
Current Input Module
500 S/s, 16-Channel C Series Voltage and Current Input Module - The NI‑9207 is a combination voltage and current input module designed with industrial systems in mind. It features eight current and eight voltage input channels, with built-in noise rejection.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
High Current Probe
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-02
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
High-Voltage Differential Probe, 100 MHz
N2790A
High Current Probe
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
Product
Injection Analyzer
-
IAV Automotive Engineering, Inc.
Instrument for the simultaneous measurement of injection rate and injection quantity. The Injection Analyzer is used for investigating hydraulic parameters in the course of development work on high-pressure injection systems.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
High Current Probe
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-02
Current Input Module
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Sample Injection System
ASXPRESS Plus
-
A sample introduction system such as the ASXpress® Plus from Teledyne LABS reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations, thereby reducing sample run times significantly. The result: more sample throughput in less time. The accessory’s design allows multiple functions to occur simultaneously. A highspeed vacuum pump loads the sample and flushes the sample uptake path substantially faster than a conventional peristaltic pump.When coupled to a compatible autosampler, the ASXPRESS Plus Rapid Sample Introduction Accessory minimizes times for sample delivery, stabilization, and washout with ICP-AES or ICP-MS. The result is increased sample throughput by up to 5 times or more. In addition, the ASXPRESS PLUS reduces costs from argon, power, ICP-AES / ICP-MS components, and system maintenance.
-
Product
sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781118-01
Current Input Module
Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9265, 4-Channel C Series Current Output Module
783733-01
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
High Current Probe
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light Collection / Injection For STEM
Mönch
-
The Mönch add-on is a unique tool that can operate in either a light collection or light injection mode, thanks to its specific mirror design. In addition, the flexibility of the add-on allows an external coupling either in free space or via an optical fiber.
-
Product
Primary Injection Test Equipment
-
High current injection units for primary testing of over current relays and circuit breakers.
-
Product
Current Generator
MIG12100
-
MIG12100 is a current generator with wave shape 8/20 ìs. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied. The generator can deliver up to 100kA impulse current supported by 12kV impulse voltage, making it ideal for testing big varistors with high hold-on voltage. Mechanically the MIG12100 consists of two large racks and a separate control console with high voltage output terminals protected by a glass acrylic test cabinet.
-
Product
Secondary Injection Test Set
PTE-100-C Plus
-
In the Pro version this voltage source incorporates a dedicated LCD display and its own BUS-PTE connection that make the operation easier and enable it to be used also with other sets in the PTE range.
-
Product
Current Probe
LFR
-
Power Electronic Measurments Ltd
The LFR is ideal for power quality applications. It has a small, predictable phase error, for power measurements at 45/65Hz. The wide bandwidth allows accurate measurement up to and even above the 400th harmonic.
-
Product
Primary Injection Test Systems
-
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
Product
Current Sensors
-
Achieve higher efficiency and power density with our industry-leading current sensor ICs. Perfect for vehicle electrification as well as green industrial, computer and consumer applications.
-
Product
Secondary Injection Test Set
PTE-100-C
-
The PTE-100-C is a portable Universal test equipment for testing electromechanical, electronic, and digital relays. The equipment can output a variable current up to 250A, a variable AC Voltage up to 250V, a variable DC Voltage up to 350V. Also the unit incorporates a variable stabilized auxiliary DC Voltage supply up to 250V and a fixed AC Voltage output up to 110V, which can be variable with the PTE-FCF option.
-
Product
Pulsed Injection Locked IMPATT Amplifiers
-
Pulsed injection locked amplifier incorporates IMPATT diode, ferrite input/output isolators, circulators, and pulse modulator. Only DC power supply, RF input signal, and external trigger signal are required to operate amplifier. Output phase noise parameters are very close to the noise parameters of the input RF signal.
-
Product
DC Coupled Current Probe
34134A
High Current Probe
Measure a wide range of applications with this battery-powered, clamp-on probe; use with DMMs or voltmeters
-
Product
Current Sensing
-
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
Product
Current Tester
MIG1248
-
The MIG1248 is a current generator with wave shape 8/20. Maximum impulse current is up to 48kA supported by a 12kV impulse voltage making the MIg1248 ideal for testing large varistors. An intergrated test cabinet can accomodate test components up to 5cm cube.





























