Current Injection
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High Current Probes
High Current Probe
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
Product
Brute High Current Probe
P4301-1Z
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-01
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
Multi-Stage Injection Analyzer
FJ-8000 series
-
Common rail method already is commonly known as an injection system of diesel engine now. That system enables multi-stage fuel injection by offering high injection pressure in various driving situation. Adopting the common rail system helps improving fuel consumption, reducing noise and vibration, because the system can make the fuel approximate complete combustion which suppresses PM and NOx generation. FJ-8000 series is the multi-stage injection analyzer that supports more accurate injection by measuring injection quantity, injection rate, injection timing, and injection period by multi-stage injection of common rail system in the environment that is near to an actual vehicle environment.
-
Product
Primary Injection Test Systems
-
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
Product
Indirect Sequential Injection
-
The ECU is designed to exploit the chemical-physical characteristics of the gas fuel used in Otto engines while maintaining the level of emissions of the exhaust gas according to the original standard car.The connector used in Air 48 is automotive type 48- Poles . The connection to the engine signals , offers exceptional qualities of connective security and protection against water infiltration .
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-02
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
Current Output Module
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
Product
Secondary Injection Relay Test Set
T 1000 PLUS
-
T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment.
-
Product
Brute High Current Probe
P4301-2R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Electronic Primary Injection Test Set
eKAM
-
eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests.
-
Product
Mixed Injection System Liquid Vaporizer
MV-2000
-
The MV-2000 achieves stable vaporization, even at low temperatures, using the new tornado flow method. This is suitable for vaporization a range of liquids even challenging sources such as "High-k", a liquid source which is pyrolyzed easily.
-
Product
Pulsed Injection Locked IMPATT Amplifiers
-
Pulsed injection locked amplifier incorporates IMPATT diode, ferrite input/output isolators, circulators, and pulse modulator. Only DC power supply, RF input signal, and external trigger signal are required to operate amplifier. Output phase noise parameters are very close to the noise parameters of the input RF signal.
-
Product
High Current Probes for EV Battery Packs
High Current Probe
Up to 500Amps - customized connections - battery pack charging.
-
Product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Comprehensive Fuel Injection Pressure Test Kit
38000
-
A complete, master fuel injection pressure tester for cars and trucks.Tests gasoline fuel injection pressure systems on virtual all domestic and imported cars and trucks.For multi-port, throttle body and C.I.S. K-Jetronic fuel Injection Systems.Supplied with complete instructions in a durable, plastic molded storage case.
-
Product
Primary Injection Test Systems
-
Weshine Electric Manufacturing Co., Ltd
1.DC display primary current, secondary current test value, easy to observe and record the experiment..2.High measuring accuracy: 0.5 level.3.Small size light weight easy to carry.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
Current Transformers
Sensors
-
The Current Transformer (CT) is the sensor which measures the amount of current draw from the wire it is installed on.
-
Product
Current Probe
PA-677
-
*Max. 70ADC/140Ap-p*Sensitivity: ≧2mA*Bandwidth: DC~1MHz*Rise Time: 0.35μS*Over Range Function*50mV/A, 500mV/A Range*Adaptor/Battery Input*Separating Design,Convenient Durable
-
Product
Current Probes
-
Innovative DC to 5MHz "positional" current probe capable of measuring currents in PCB tracks, component legs etc. without the need to break the connection or surround the conductor.
-
Product
Epoxy Injecting Machine - EIM-280
-
Shanghai Fibretool Technology Co.,Ltd.
1, Injecting Epoxy Adhesive into ceramic ferrules for fiber optic connectors.2, High Accuracy to control epoxy dosage.3, Easy to adjust output pressure and injecting time.4, With hand touch switch and foot switch.5, Compact for production line.
-
Product
Current Source
M151
-
Clarke-Hess Communications Research
The Model M151 is a stable high current calibrator up to 120 A. Basic accuracy is 0.035 %. It can be controlled viaRS232 or GPIB interface. The Model 151 can function in a simulated amplifier mode to increase the current capabilityof any multifunction calibrator. It is suitable for power meter calibration because it can be synchronized with the inputsignal not only in amplitude but also in frequency and phase. The current terminals are isolated up to 450 Vpk againstcase (protective earth).
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Fuel Injection Pressure Tester Bleed-Off Kit
37400
-
Adds a bleed-off feature to our Cat. Nos. 33770, 33800, 33865, 33900, 33950, 33980, 53770, 53900, 53950, 53980, (This feature is included with Cat. Nos. 36200, 36250, 38000, 53800, 53865, 56200, 56250 & 58000 ).