Product
Pocket-Sized Analyzer for Capturing & Decoding USB 2.0 Devices
Mercury T2C / T2P
Analyzer
The pocket-sized Mercury T2C & T2P capture and decode the widest range of USB 2.0 device classes plus Type-C link states and Power Delivery 3.0 messages. Both the Mercury T2C and T2P utilize the industry leading CATC Trace analysis software for verifying and debugging USB and PD protocol issues. Now there are two base models to choose from; the original Mercury T2C and the new Mercury T2P, which adds the Power Tracker graphical view of VBUS and CC voltages.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
PXI Vector Component Analyzer, 100 kHz to 26.5 GHz
M9815AS
Vector Component Analyzer
The PXI vector component analyzer (VCA) enables complex multiport device characterization with continuous wave (CW) and modulated signal measurements.
-
Product
PXI Vector Component Analyzer, 100 kHz to 53 GHz
M9818AS
Vector Component Analyzer
The PXI vector component analyzer enables complex multiport device characterization with continuous wave and modulated signal measurements.
-
Product
Quadrupole Mass Spectrometer for Residual Gas Analysis
RGA Series
-
Systems for the examination of components present in a vessel or evolved from a process. HALO RGA – for residual gas analysis. 3F Series RGA – triple filter mass spectrometers for analytical applications. 3F-PIC – pulse ion counting detection for fast event studies. Measures the concentration of gases and vapours in real time.
-
Product
PXI Vector Network Analyzer
Vector Network Analyzer
PXI Vector Network Analyzers feature two ports, so you can choose between T/R test sets or full S-parameter capabilities. The PXI Vector Network Analyzer supports automatic precision calibration, full vector analysis, and reference plane extensions, so it is an ideal vector network analysis solution for your validation and production operations without the high cost and large footprint associated with a traditional benchtop VNA. These models seamlessly integrate into test systems for highly accurate, fast RF measurements.
-
Product
Transportable NOx-O2 Gas Analyzer
NOA-7100
-
The NOA-7100 adopts the normal pressure chemiluminescence method is adopted for NOx measurement, and the zirconia method is adopted for O2 measurement. NOA-7100 is “All-in-one portable analyzer” that incorporates the pretreatment parts needed for measurements. Switching between eight ranges from 25 to 4,000 ppm supports a wide range of NOx measurements. The NOA-7100 has wireless communication capability, so measurement values and charts can be displayed on PCs or smart devices. And measurement data can be exported using a USB flash drive.
-
Product
Streamline Vector Network Analyzer, 9 KHz To 14 GHz, 2-port
P5003B
Vector Network Analyzer
Compact, faceless, vector network analyzer (VNA). Flexible two-port VNA dramatically reduces your size of test. Up to 14 GHz.
-
Product
Streamline USB Vector Network Analyzer, 32 GHz
P5026A
Vector Network Analyzer
Compact, faceless, USB vector network analyzer (VNA). Flexible two-port VNA which dramatically reduces your size of test. Up to 32 GHz.
-
Product
PNA-L Microwave Network Analyzer
N5232B
Network Analyzer
Perform basic analysis of passive components and simple active devices Measure S-parameters with good accuracy up to20 GHz in cost-sensitive applications Get the world's best price-to-performance ratio for microwave manufacturing Configure an economical solution for signal-integrity measurements and materials characterization Accelerate insight into component behavior using a multi-touch display and intuitive user interface Every spec verified, adjustments included Lock in support & peak performance from the start
-
Product
Measuring Device For Measuring Residual Magnetism
Teslameter M-Test LL
-
Measure residual magnetism on ferromagnetic materials precisely and reliablyquick detection of residual magnetismreproducible measurement results through automatic storage of the maximum valuesdefined measuring distance of 0.5 mm from the Hall probe to the measuring surfacemeasuring static and alternating magnetic fieldsselectable units: A / cm, Gauss, mTwear-resistant test sample
-
Product
PCI Express 5.0 Protocol Exerciser/Analyzer
Summit Z58
Analyzer
The Summit Z58 is a PCIe 5.0 protocol traffic generation test tool used for critical test and verification intended to assist engineers in developing and improving the reliability of their systems. The Summit Z58 can emulate PCI Express 5.0 root complexes or device endpoints, allowing new designs to be tested against corner case issues.
-
Product
Headspace MAP Gas Analyzers
-
Headspace analysis is conducted to ensure that the residual oxygen in a product complies with predefined limits. This is a vital part of the Quality Control of Modified Atmosphere Packaging (MAP) products. For packaged foods and other goods, exceeding these limits increases the risk of growth and proliferation of bacteria or mould, which causes spoilage and results in shorter product shelf-life.
-
Product
Self-reclosing Overcurrent And Residual Current Protection
-
Wide range of solutions to guarantee personnel safety as well as maximum service continuity in the event of a ground current or breaker trip, with automatic reconnection of the installation. Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
Product
Streamline Vector Network Analyzer, 100 KHz To 32 GHz, 2-port
P5006B
Vector Network Analyzer
Compact, faceless, vector network analyzer (VNA). Flexible two-port VNA dramatically reduces your size of test. Up to 32 GHz.
-
Product
Trace Gas Analyzers
-
Campbell Scientific offers both open-path and closed-path trace gas analyzers for measuring carbon dioxide and water vapor. Campbell Scientific also offers a closed-path analyzer for measuring methane, nitrous oxide, or isotopologs of carbon dioxide.
-
Product
Gas Mixers / Gas Blenders
-
WITT offers high-quality gas mixers and gas dosing systems for two or more gases, especially for high and strongly fluctuating gas mixture flow rates.
-
Product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
-
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Gas Chromatographs
-
Teledyne Analytical Instruments
Gas Chromatographs by Teledyne Analytical Instruments
-
Product
Motor Exhaust Gas Sulfur Analyzer
MEXA-1170SX
-
The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Real-Time Analysis, 255 MHz, Basic Detection, Multi-touch
N9040B-RT1
Signal Analyzer
See, capture, and understand elusive signals as short as 17.17 s with 100% POI and a complete set of advanced triggers View signal dynamics with integrated real-time displays Maximize your investment by adding RTSA at a fraction of the cost of a dedicated solution Easily integrate the 89600 software and thoroughly analyze complex signals Industry-leading 3 year warranty Every spec verified, adjustments included Lock in support & peak performance from the start
-
Product
Residual Gas Analyser For Process & Research
(QMS)
-
Quadrupole Mass Spectrometer Analyser System for low volume, quick responding gas measuring with large dynamic range Quadrupole Mass Spectrometer (QMS) for low volume, quick responding process gas measurement with large dynamic range.
-
Product
Multiplex for Rapidox Gas Analyzers
Rapidox 2112
-
The Rapidox 2112 Multiplex is housed in a 19″ rack mount unit and allows a programmed sequence of gas samples to be fed to a single gas analyser, thus saving money and space requirements.
-
Product
N2O/H2O Trace Gas Analyzer
LI-7820
-
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems. Pair it with the LI-7810 CH4/CO2/H2O Trace Gas Analyzer or LI-870 CO2/H2O Analyzer for CO2 and CH4 measurements at your site.
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
OEM Gas (NO) Analyzer
BE-220FSD
-
The BE-220FDS is an OEM NDIR detector for measuring NO in automotive emission gases. The BE-220FSD can output NO concentration by digital data and analog voltage. In addition, it can be connected with the HORIBA BE-150 bench by serial line and relay the commands for BE-150. The BE-220FSD meets OIML Class 0 and complies BAR-97 & GB18285-2018 specifications.
-
Product
Gas Chromatography
GC3420A
-
Gas Chromatograph Based unitSelf-diagnostic function: 1) Core tests; 2) Automatic tests; extended tests , basic test. Self-protective function: 1) Overrun temperature protection 2) Short circuit hint; 3) TCD filament protection;4) FID flameout hint; 5) PFD exposed-light protection; 6) Keyboard locking with password; etc., ensuring normal running Simple operation, powerful automation: 1) All parameters can be entered through keyboard with prompt function; 2)4 sets of complete chromatography analysis methods can be stored and recalled automatically
-
Product
CX4000 – FTIR Gas Analyzer
-
Gasmet CX4000 is an industrial multi-component FTIR gas analyzer for continuous emission monitoring applications, integrated into a Continuous Emissions Monitoring system (CEMS II e). It can be used to measure up to 50 components simultaneously, and additional gases can be easily added without any hardware changes. The corrosion-resistant sample cell is heated up to 180 °C, which makes CX4000 an ideal tool for analyzing trace concentrations of pollutants in wet, corrosive gas mixtures.