Filter Results By:

Products

Applications

Manufacturers

SCR

Thyristor, Silicon Controlled Rectifier


Showing results: 46 - 60 of 73 items found.

  • MCB Tripping Current Characteristic Test Bench

    SCR ELEKTRONIKS

    The SCR Elektroniks 12 station MCB Tripping Characteristics Test Bench is optimally designed to verify the Tripping Characteristic of MCBs as per clause 9.10.1 of IEC 60898 (Also mentioned in Indian Standards IS 8828). The bench essentially comprises of Servo Controlled mechanism to set and maintain desired current (against incoming mains fluctuation) and a Micro controller based master controller unit plus timer, which governs the entire sequence of operation making it a stand-alone system once the user connects the MCB and configures the test parameters.

  • MOTORIZED VARIABLE TRANSFORMER CONTROLLED POWER SUPPLY

    Carl E. Holmes Company

    Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure

  • Abrasion Test Setup for Coating of Hair Straightener

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed "4 Stations Abrasion Test Setup for Coating of Hair Straightener" for Testing of Hair Straightener. It consists of Adjustable Constant Voltage source, Digital Timer, Digital Voltmeter, Digital Timer for carrying out Heating Test of Hair Straightener. It has got the capacity to check hair straightener that require test current 28 A at different Test Voltages.

  • MCB Instantaneous Trip Test Bench

    SCR ELEKTRONIKS

    The SCR Elektroniks MCB Instantaneous Trip Test Bench is designed for Testing of MCB to carry out “Test of Instantaneous Tripping and of correct opening of the Contacts” as per IEC: 60898-1:2002 Clause 9.10.2 at rated voltage. This test is carried out with power factor between 0.95 and 1 with the sequence operation being O-t-CO-t-CO-t-CO with timings as specified in 9.12.11.1.

  • MOTORIZED TRANSFORMER/RECTIFIER ASSEMBLY, 0-250 VDC, 200 A OUTPUT

    18534PS1 - Carl E. Holmes Company

    Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure

  • Shock Test Apparatus

    SCR ELEKTRONIKS

    SCR Elektroniks make Shock test Apparatus is used to test the Electrical accessories / appliances for their mechanical strength. A wooden base fixed to a concrete block and a wooden platform is hinged base. This platform carries a wooden board, which can be fixed at various distance from the hinge and two vertical positions. The end of board bears a metal stop plate, which rests on coiled spring having constant 25N/mm.

  • MCB Endurance Test Bench

    SCR ELEKTRONIKS

    The SCR Elektroniks Endurance Test Bench is designed for electrical and mechanical endurance MCB and RCCB as per clause 9.11 of IEC 60898-1. The source and the load is designed to comply as per the general test conditions specified in Cl 9.11.1. The accompanying pneumatic fixture is designed to hold custom built designs of MCB and RCCB while the microcontroller based timer unit can be configure to follow test procedure summarized in Cl 9.11.2.

  • AdBlue & Urea Refractometer

    RHA-503ABATC - Fuzhou Zhongtuo Optoelectronic Co.,Ltd

    The AdBlue refractometer RHA-503ABATC is a new hand held refractometer developed to address the growing need to check the urea concentration in AdBlue.Escalating urea prices have driven the cost of operating an SCR higher than ever before. Regretfully this has led to a new wave of problems where supplies of diluted AdBlue have found their way in to the market.Often rebranded ‘Automotive urea solution’ to eliminate the risk of prosecution by trading standards (as a mix of less than 31.8% urea cannot be labelled AdBlue). Victims of this weaker concentration may not be able to seek compensation under the Trades Description Act.

  • Stored Energy Solenoid Drivers

    B-1014 - ROSS ENGINEERING CORPORATION

    The remote contact controlled HCA Series and the SCR controlled HCB Series of Stored Energy Solenoid Drivers produced by Ross Engineering Corporation are used for high speed opening or closing of Ross Circuit Breakers and Contactors. They perform high speed microseconds to milliseconds actuation of various electromechanical devices. The units feature minimum internal time delay, trigger signal overload protection, and up to 3000 joules of energy storage.

  • Cord Grip Test Apparatus

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS focuses on designing a solution around the end use at her customer. Instead of offering a standard instrument for a specific task, we have an approach of customizing the test bench to target the specific goals of the process or test procedure. Our measurement instruments, test modules, electrical power systems & software libraries are developed with this vision, thereby reducing the test system’s time-to-deploy. Cord Grip Test Apparatus for testing effectiveness of the retention in flexible cables.

  • 5000 AMP DC Rectifier - Air Cooled, P/N 6037C1

    Carl E. Holmes Company

    Air Cooled SCR Controlled Power Supply, 50 KW, P/N 6037C1Input: 480 VAC, 60 Amps, 3 PH, 60 HzOutput: 6 to 10 VDC, 5000 Amps maxContactor and overload relay are installed for protectionStart / Stop capabilityEPO capabilityManual voltage control and current limitOutput voltage and current are displayed on the voltmeter and ammeterIndoor enclosure, 68″H x 65″W x 36″DAll input/output connections are inside the enclosuresEstimated weight: 1000 lbs.

  • AC to AC Power Supplies, Output 0 to 25 VAC, 3000 AMPS, 75 KW, P/N 5955C

    Carl E. Holmes Company

    - AC to AC Power Supply, 84 KVA, 1 PH, 60 Hz, P/N 5955C- Input: 240 VAC, 350 Amps- Output: 0 to 25 VAC, 3000 Amps max- Back to back SCR is used to adjust the output voltage- Start / Stop push button- Power ON Light- Voltmeter and Ammeter are included to monitor output voltage and current- Indoor enclosure: 42″H x 32″W x 22″D- Estimated weight: (TBD)

  • Safety Test Panel for Geyser

    SCR ELEKTRONIKS

    Electrical Safety is the most primary and essential product conformity requirement for any product that uses electricity. The clauses of safety testing of electrical products laid by worldwide agencies such as UL, CE, BIS, etc. are stringent. The products need to pass through tests such as the high voltage test, insulation resistance test, earth bond test, leakage current test and so on. And to conform to such tests, SCR Elektroniks have developed for the testing of Geyser. In addition to the conventional safety tests, test for performance is also included.

  • Relays for High Power Applications

    Series ST - Teledyne Defense Electronics Relays & Coax Switch

    Series ST relays are designed for high-power applications. The design incorporates an SCR or triac output. The relays utilize optical isolation to protect the control from load transients. A control LED is available on certain models. Internal MOV is also available on ST24D 25A and 50A models.​ All Series ST relays are Zero-Cross switching.Available options include:ST24D12 12A, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control​ST24D25 25A, 12-280Vrms, 600Vpeak Load; 4-30Vdc ControlST48D50 50A, 24-600Vrms, 1200Vpeak Load; 5-30Vdc Control

  • Test Setup For Air Conditioner

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.

Get Help