Oscilloscopes
Analyze waveforms of electronic signals by producing a trace on a display screen of corrosponding oscillations of voltage and current.
See Also: Scopes, Fiberscopes, Microscopes, Borescopes, Endoscopes, Stethoscopes, Stroboscopes, Synchroscopes, Telescopes, Vectorscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes, Oscilloscope Probes, Waveform, Digitizers
-
product
Super Phosphor Oscilloscopes
SDS1000X-E Series
SIGLENT’s new SDS1000X-E Series Super Phosphor Oscilloscope is available in 100 and 200 MHz bandwidths and 2 or 4 analog channels. It has a maximum sample rate of 1 GSa/s and a standard record length of 14 Mpts. For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design.The SDS1000X-E series employs a new generation of SPO (Super Phosphor Oscilloscope) technology that provides excellent signal fidelity and performance. The system noise is als...show more -
product
Oscilloscopes
Oscilloscopes are essential tools in an electronic world. Used in a wide variety of applications such as design, service, manufacturing, and education.
-
product
Bench Oscilloscopes
PeakTech Prüf- und Messtechnik GmbH
Bench Oscilloscopes for Design, Debug and Education
-
product
Transverse Hallprobe with Analog Output
KOSHAVA-AT
The independently operating Tesla Meter / Gauss Meter Type KOSHAVA analog for connection to a digital multimeter, oscilloscope, data logger or data acquisition card is an inexpensive alternative to the handheld and USB Tesla meter / Gauss meters.
-
product
Oscilloscope 59 GHz, 2 Channels, 1 mm Inputs
UXR0592BP
The UXR0592BP is the 59 GHz, 2 channel, 1mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
Infiniium UXR-Series Oscilloscope: 50 GHz, 4 Channels
UXR0504A
The UXR0504A is the 50 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope
-
product
O/E Converter
TIA-3000
The TIA-3000 is an instrument for the laboratory or for field use. This amplified optical-electrical converter can be used with a wide range of oscilloscopes and digitisers to provide the utility of a convenient, easy to use fibre optic probe. Energising the unit, the optical signal presented to it is faithfully reproduced on the CRT of the oscilloscope or digitiser.
-
product
PXIe-5171 Oscilloscope, 250 MHz, 250 MS/s, 8-channel
783692-01
MHDMR - Mini HDMI, I/O Receptacle PXIe, 250 MHz, 8-Channel, 14-Bit, Kintex-7 410T FPGA Reconfigurable PXI Oscilloscope—The PXIe‑5171 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling and voltage range. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 250 MS/s or 250 MHz of analog bandwidth and advanced PXI synchronization.
-
product
500A AC/DC Current Sensor
CT6904
Hioki pull-through AC/DC current sensors are best-in-class devices for use with power analyzers,, Memory HiCorders and high performance oscilloscopes. The CT6904 is a DC to 4 MHz/500A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.
-
product
High Voltage Differential Probe
DP750-100
Shenzhen Micsig Instruments Co., Ltd.
*The leads and probe are with shielded design, interface ends are integrated in a compact box, no need to twist the cables, leads to a lower noise floor and has less interference. *Support one-press Zero calibration and automatic overrange alarm.*Directly powered by Micsig UPI interface, realise auto scaling setup, can also powered by oscilloscope via USB cable.
-
product
PC Oscilloscopes & Mixed Signal Oscilloscopes
PicoScope® 3000 Series
PicoScope 3000 Series USB-powered PC oscilloscopes are small, light, and portable and can easily slip into a laptop bag while offering a range of high-performance specifications.
-
product
Analog Oscilloscope
FS-409
*OSCILIOSCOPE: 40MHz Dual Trace,Dual Trigger. 1mV Sensitivity. 10ns Resolution.*FUNCTION GENERATOR: 0.5Hz~5MHz Frequence. Sine,Square,Triangle,3 waveforms. Max output:20 Vp-p(No Load),10 Vp-p(50O Load). TTL Synchronous Output.*COUNTER: 5 Digits 0.36" Red LED Display.
-
product
Oscilloscope 200 MHz, 2 Analog Channels
DSOX3022G
The DSOX3022G 200 MHz oscilloscope provides 2 analog channels, 4 Mpts memory, 1,000,000 waveforms/sec update rate, zone touch trigger with an 8.5-in capacitive touch screen, and standard embedded software with waveform and measurement histograms.
-
product
Oscilloscope - 200 MHz, 2 Analog Channels
DSOX4022A
200 MHz2 analog channels Easily view signals on the large 12.1-inch capacitive touch screen Isolate signals in seconds with exclusive Zone touch triggering Capture more data with 4 Mpts memory with segmented memory standard See more signal detail with the 1,000,000 wfms/s update rate Expand your measurement capabilities with full upgradability: Add bandwidth, digital channels, Dual-ch 20 MHz arbitrary waveform generator, 3-digit DVM, serial trigger and analysis & mask testing at any time
-
product
PXI Oscilloscope 2 Channel, 250Msa/s
PXI‑5114
The cost-optimized PXI‑5114 oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also offer a variety of trigger options, large onboard memory, and a device driver that includes streaming and analysis capabilities. The device is particularly suitable for applications with fast signals that require flexible measurement configurations and an analog bandwidth of up to 125 MHz. The PXI‑5114 also features PXI‑based synchronization and data streaming capabilities.
-
product
PXIe-5105, 60 MHz, 8-Channel 512 MB, 12-Bit PXI Oscilloscope
783590-03
PXIe, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXIe‑5105 also features advanced PXI synchronization and data streaming capabilities.
-
product
Current Probe With Hall Effect Technology
CP 35
The CP 35 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
product
Infiniium V-Series Oscilloscope: 8 GHz, 4 Analog Channels
DSOV084A
8 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (1.04 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
product
Mixed Signal Oscilloscope: 70 MHz, 4 Analog Plus 8 Digital Channels
MSOX2004A
70 MHz4 analog plus 8 digital channels Easily view your signals on the 8.5-inch WVGA display Capture more data with up to 1 Mpts memory See more signal detail with 50,000 wfms/s update rate Expand your measurement capabilities with full upgradability: Add 20 MHz function generator, 3-digit voltmeter, serial trigger and analysis, segmented memory & mask testing at any time Easily set up teaching labs with our free Educator's Resource Kit
-
product
HandyScope HS5 + SureConnect: 100 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 10MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-110XMS-W5
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 100 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
product
Mixed Signal Oscilloscope 500 MHz, 4 Analog Plus 16 Digital Channels
MSOX3054G
The MSOX3054G 500 MHz oscilloscope provides 4 analog plus 16 digital channels, 4 Mpts memory, 1,000,000 waveforms/sec update rate, zone touch trigger with an 8.5-in capacitive touch screen, and standard embedded software with waveform and measurement histograms.
-
product
Mixed Signal Oscilloscope: 13 GHz, 4 Analog Plus 16 Digital Channels
MSOV134A
13 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
product
AC/DC Current Probe, 100 MHz, 15A
N2893A
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.
-
product
PXIe-5114, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope, 256 MB
783591-03
PXIe, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXIe‑5114 low-cost PXI oscilloscope has two channels that sample up to 250 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXIe‑5114 also features advanced PXI synchronization and data streaming capabilities.
-
product
Digital Oscilloscope, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A
The 72-8710A from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides trigger modes edge, pulse, and alternate.
-
product
Oscilloscope 33 GHz, 4 Channels
UXR0334B
UXR0334B Infiniium UXR-Series is the 33 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope, that offers 10-bit high-definition ADC, 20 femtoseconds (typical) of intrinsic jitter for exceptional jitter characterization.
-
product
High Definition Oscilloscope, 1 GHz Bandwidth, 4 Input Channels, 10 GS/s
HDO4104A
1 GHz, 10 GS/s, 4 Ch, 12.5 Mpts/Ch 12-bit HD Oscilloscope with 12.1" WXGA Color Display.
-
product
PXI-5105, 8-Channel, 12-Bit, 60 MHz PXI Oscilloscope
779685-01
60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXI‑5105 high-density PXI oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXI‑5105 also features PXI synchronization and data streaming capabilities.
-
product
High Voltage Probe: Single-Ended
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for oscilloscopes with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.