Showing results: 16 - 30 of 106 items found.

  • AC Leakage Current Tester

    229-2 - Simpson Electric Company

    Testing for dangerous small leakage currents is easy with the Simpson Model 229-2 Leakage Current Tester. For use in appliance field service, in the lab, or in production, the 229-2 approximates the human threshold of perception in detecting hazardous AC leakage current. The 229-2 comes with test leads with alligator clips, manual and batteries. 

  • Duct Air Leakage Tester

    6900 - KANOMAX USA, Inc.

    Kanomax has developed the most advanced Duct Air Leakage Tester (DALT) for commercial duct systems. It’s designed to be simple to use, accurate, and extremely convenient. The instrument provides step-by-step duct leakage test configuration and automated leakage testing based on the SMACNA HVAC Air Duct Leakage Test Manual, and is accurate to ±2.5% of reading. Though built tough with an on-board, powerful motor, the DALT 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • Automated Leakage Current Tester

    LINECHEK® II Series - Associated Research

    Our LINECHEK II Leakage Current Tester is designed for medical device manufacturers. With a feature set built around maximizing the efficiency of the Leakage Current test, LINECHEK II satisfies medical application requirements demanding up to 40 Amps of continuous line current. Use it on the bench or in a rack, from the front panel or via a PC interface to ensure your medical device is ready for global deployment.

  • Digital Leakage Current Tester

    Educated Design & Development, Inc.

    Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.

  • Leakage Current Clamp Tester

    M-1141 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency(fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight

  • AC/DC Leakage Current Tester

    228 - Simpson Electric Company

    Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries. 

  • Cylinder Leakage Tester Kit

    CLT200 - Matco Tools

    Quickly locates internal engine problems such as bad rings, valves and leaking head gaskets. Dual 2-1/2" heavy duty gauges with protective outer boots. Scales read 0-100psi and 0-700 kg/cm2Pressure regulated manifold includes high quality quick couplers for fast set-ups.

  • GAOTek Three-Channel Leakage Current Tester

    GT00YB00ZV - GAO Tek Inc.

    The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.

  • Leakage Current Clamp Tester with Bluetooth

    M-1141XR - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight

  • Leakage Current Tester for Ultrasound Transducers

    SECULIFE UL Series - GMC-I Messtechnik GmbH

    The SECULIFE UL Series is specifically designed to test the electrical safety of all types of diagnostic ultrasound transducers, totally independent of the ultrasound machines on which they are typically used. Although the SECULIFE UL can be used on virtually any type of ultrasound transducer, it is especially recommended in the testing of TEE (Transesophageal Echocardiography) transducers prior to each use.

  • AC Current / Leakage Digital Clamp-on Tester

    MCL-500DFN - MULTI MEASURING INSTRUMENTS Co., Ltd.

    MCL-500DFN AC Current / Leakage Digital Clamp-on Tester

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • Leakage Current Tester and Clamp-On Earth / Ground Resistance Tester

    Meco Instruments Pvt. Ltd.,

    10µA Ultra High ResolutionLarge Conductor Diameter (30mm)AC Current in 5 Ranges (40mA, 400mA, 4A, 40A, 60A)Wide Frequency Response (40Hz-1KHz)ACA, ACV, Ω and ContinuityLarge 3¾ Digit LCD (4000 Count)40 Segment Fast Bargraph Display (20 times/sec.)Data Hold and Max / Min HoldRelative Measurement600 Vrms Overload Protection in Resistance Range