Showing results: 3511 - 3525 of 4155 items found.
-
N9912C -
Keysight Technologies
Select from cable and antenna analyzer (CAT), Vector Network Analyzer (VNA), and/or Spectrum Analyzer with desired maximum frequency. Capture elusive signals with up to 40 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
4112 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.
-
Innerspec Technologies, Inc
The PCI-8 is an 8-channel, PCI-based AE system on a board. Its 8 high-speed AE channels offer simultaneous AE data acquisition, waveform processing and data transfer. The board’s standard PCI form factor enables installation in standard PCs, as well as in any of Physical Acoustics’ specialized AE system chassis, while the PCI bus enables AE data transfer at speeds of up to 132 Mb/s, at a frequency range of 1 kHz to 400 kHz.
-
STP-01RAN/STP-01RFN/STP-01RFB -
HK Film Capacitor Ltd
This series of capacitors is Plastic Enclosure, Dry construction design and doesn't have leakage problem when compared with traditional Metal Enclosure Oil impregnated capacitors.Handle Medium Frequency range, high surge current, RMS current and surge voltage with temperature up to +105CCapacitance : 0.1uF - 15uF ( can be customized )Voltage range : 1,200Vdc to 17,000Vdc / 350Vrms to 6,900VrmsRMS Current - Irms : up to 100Armspeak to peak pulse current - Ipp : up to 5,900AppTemperature ranges : +85C / +105C
-
40-881-001 -
Pickering Interfaces Ltd.
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
40-881-002 -
Pickering Interfaces Ltd.
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
Data Patterns Pvt. Ltd.
The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.
-
Model 5791 -
Pentek, Inc.
- Simultaneous synthesis of up to five different clocks- Eight SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Four programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Model 5891 -
Pentek, Inc.
- Simultaneous synthesis of up to 10 different clocks- 16 SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Eight programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Model 71624 -
Pentek, Inc.
- Modifies 34 IF signals between input and output- Up to 80 MHz IF bandwidth- Two 200 MHz 16-bit A/Ds- Two 800 MHz 16-bit D/As- 34 DDCs and 34 DUCs (digital downconverters and digital upconverters)- Signal drop/add/replace- Frequency shifting and hopping- Amplitude boost and attenutation- PCI Express Gen 1: x4 or x8- RoHS Compliant Lead-Free Version Available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
LV-7000 series -
Ono Sokki
The LV-7000 series detects speed, uneven speed, distance, length of moving object or rotating object without contact. By contacting with 2 sensors, it enables to calculate difference in velocity/length between the two points in real time and output with 3,000 ppm of accuracy. The frequency response can be expanded up to 20 kHz, which achieves to understand phenomena and evaluate mechanical systems at high speed, efficiently, and accurately. It is useful for evaluation of motor control and behavior measurement, improving parts quality, and reducing loss of material.
-
MM94 -
Martindale Electric Co. Ltd
The MM94 is a high performance True RMS multimeter with a 600V CAT IV safety rating.
It has an extended current measurement range up to 20A for short cycle measurements. Measurement capabilities include AC/DC voltage, capacitance, resistance and temperature with the included K Type thermocouple. Features include Min/Max and Peak measurement and a high frequency filter to optimise readings for distorted waveforms plus a relative mode.
The rugged design includes a 60,000 count backlit display with analogue bargraph.
-
Series ABC -
Kepco, Inc.
Kepco¹s ABC bench power supply embodies the latest features: keyboard data entry, interactive digital display, integral GPIB support, software calibration, high frequency switch mode conversion, wide range input (85-264V a-c) and power factor correction. It meets the EN 61000-3-2 harmonic limits. A built-in EN 55022 Class B input EMI filter is provided. Integral External Trigger and RS 232 ports are now standard features.
-
FLIR CM46 -
Teledyne FLIR
The FLIR CM46 clamp meter is designed for commercial and residential electricians. Featuring both AC/DC measurement, the meter is equipped with a bright backlit display for use inside electrical panels. Accu-Tip™ technology delivers amperage measurements on smaller-gauged wires more accurately — to a tenth of a digit. The meter also offers MAX/MIN/AVG recording; measures DCµA, temperature, capacitance, and frequency; and has electrical field detection to help you determine voltage presence and relative strength of the field.
-
upj10 -
KEYCOM Corp
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.