  • Pulse energy and power measuring instrument

    LEM 2410 - Scitec Instruments Ltd

    A touch panel and function keys make this device comfortable and easy to handle. The preamplifiers integrated into the device and the choice of sensor sensitivity allow a wide range of sensor heads to be used. The large graphic display offers space for a variety of display and analysis choices. The digital display can be used for determining the energy, frequency and average power.

  • Hydrophone

    RESON TC 4035 - Teledyne Marine RESON B.V.

    ​The TC4035 is a miniature probe hydrophone specifi cally designed as a standard reference hydrophone for sound measurements in the frequency range 100 to 500kHz. The hydrophone incorporates a 10dB low-noise preamplifier, which includes an insert calibration circuit for convenient electrical testing of the hydrophone condition. The pre-amp has a drive capability for cable length up to 25 meters.

  • Octal Digital Multi Channel Analyzer

    V1782 - CAEN S.p.A.

    The V1782 is the new CAEN Octal 32k digital MCA. Designed for high energy resolution semiconductor detector is perfectly suited for those application in which the number of input channels start becoming relevant such as when segmented HPGe, Clovers and silicon detectors are involved.The V1782 provides four steps of software selectable coarse gain and two possible jumper selectable dynamical ranges (0.2-0.4-0.8-1.6 Vpp and 1-2-4-8 Vpp).It is also compatible with Transitor reset preamplifier thanks to the jumper selectable 10 us AC coupling.

  • Charge Sensitive Preamplifier-Discriminator

    A101 - Amptek Inc.

    Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.

  • Digital MCA Tube Base For Gamma-Ray Spectroscopy

    Gamma Stream Family - CAEN S.p.A.

    CAEN Gamma stream is a compact and portable system for gamma ray spectroscopy with scintillation detectors, which provides an active Multi-Channel Analyzer (MCA) integrated in a 14-pin photo-multiplier tube (PMT) base. Gamma stream fully integrates in a stand-alone device the high voltage to bias the PMT, the preamplifier to shape the signal from detector, and the MCA for a complete Pulse Height Analysis online.

  • ProBus Probe Adapter for TekProbe-BNC Probes

    TPA10 - Teledyne LeCroy

    - Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes

  • Sound Level Meter

    831-LOWN - Larson Davis, Inc.

    Easily make low noise measurements to 6.5 dB A-weighted using the Model 831-LOWN sound level meter paired with the 378A04 low noise microphone and preamplifier. Due to the innovative design of the 378A04 which uses a prepolarized microphone and ICP (constant current) interface, the combination produces a highly portable system that is battery powered and intuitive to use for measuring low noise levels.

  • Power modules

    G.R.A.S. Sound & Vibration A/S

    It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation

  • Multiplexed Amplifier-per-Channel Function Card

    Neff Instrument Corporation

    Multiplexed amplifier-per-channel systems have a dedicated pre-amplifier for every channel and a single Analog to Digital Converter, ADC, for the system. Amplified and filtered analog signals are multiplexed to a post-amplifier and then presented to the ADC to be digitized. Significant benefits of the multiplexed amplifier-per-channel system are: Higher Throughput Rates, Improved Filtering, Higher Per Channel Sampling Rate, Sensor Isolation, Improved Channel-To-Channel Isolation

  • Headphone Test Fixture

    AEC206 - Larson Davis, Inc.

    The Larson Davis Model AEC206 Binaural Test Fixture is the tool for testing supra-aural, circumaural, supra-concha, intraconcha, and insert-type headphones. Preassembled with IEC 60318-4 (711) occluded-ear simulators and TEDS compatible preamplifiers that provide electronic calibration information, the Model AEC206 is user-friendly and easy to learn. Additionally, calibration is a simple process—a custom adapter is included for the Model CAL250 acoustic calibrator or similar device.

  • Modular Pulse Processing Electronics

    CAEN S.p.A.

    CAEN provides a complete and ever increasing set of instrumentation, from Preamplifiers to Data Acquisition to Triggering Electronics and Logic Functions. Most of the instrumentation is available in the most popular standard form factors and bus protocols, such as VME, NIM, CAMAC and Desktop.The Desktop is the stand alone form factor of the CAEN products. It provides the same performances of the other form factors and take the advantage of an easier and portable use, requiring no crates.

  • CZT-based Radiation Detector

    SPEAR - Kromek Group plc

    A CZT-based gamma radiation and x-ray detector perfect for immediate use (using Kromek KSpect or MSpect gamma spectroscopy software) or as the gamma radiation and x-ray detector component in your own radiation detector. Being CZT-based the SPEAR (Single Point Extended Area Radiation) can operate at room temperature while still offering high sensitivity. The SPEAR detector is a complete probe, comprising a 5x5x5mm3 CZT detector crystal and low noise hybrid preamplifier in a housing measuring only 13mm diameter x 84mm in length. The probe is supplied complete with a 2 metre long connecting input/output cable, allowing the unit to be used immediately.

  • LISN & Voltage Probes

    Laplace Instruments Ltd.

    All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.

  • Shield Level / Pathloss Equipment

    SG1000B/PR1000A - Praxsym

    The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.​To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.

  • Read-Write Analyzers

    Guzik Technical Enterprises

    Guzik Read/Write Analyzers (RWA) work in conjunction with Spinstands to write data to the disk media and read back the signal for detailed analysis. We have two RWA-4000 series available for For Two Dimensional Magnetic Recording (TDMR) and non-TDMR technologies. The RWA 4000 series offer upto 8Gbit/sec maximum write data rate and 3.5 GHz analog bandwidth for all parametric measurements. Each RWA features a pattern generator with 1psec resolution of bit pre-compensation and supports PRML chip integration. Servo writing and processing is provided for Guzik Spinstand models. Select the pre-amplifier (UP14) as well as a variety of enhancements including programmable filters and PRML chip adapters.