Rubidium Standards
In telecommunication, a rubidium standard is a frequency standard in which a specified hyperfine transition of electrons in rubidium-87 atoms is used to control the output frequency. (www.encyclopedia.thefreedictionary.com)
See Also: Rubidium Reference, Rubidium Oscillators, Frequency Standards, Rubidium Frequency Standards
-
Product
Qseven® Standard Size Module with Intel Atom® E3900, Pentium® N4200 and Celeron® N3350 Processor (codename: Apollo Lake)
Q7-AL
Computer on Module
The Q7-AL Computer-On-Module (COM) combines the QSeven® 2.1 standard with the Intel (“Apollo Lake”) Atom® E-series and Pentium® and Celeron® N-series System-on-Chips (SoCs), providing ideal solutions for low power consumption and high pin/area density requirements. The module provides the high integration, high performance, low power, and ruggedness favored by Internet-of-Things (IoT) applications such as retail transactional clients, digital signage, and in-vehicle infotainment systems.
-
Product
Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I15-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
-
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40C
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4C
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard High Speed A/D Converters
-
Analog Devices high speed A/D converters (ADCs) offer the best performance and highest sampling speed in the market. The product offerings include low IF A/D converters (20 MSPS to 125 MSPS), high IF a/d converters (125 MSPS to 1.3 GSPS), and wideband ADCs (>1 GSPS). The high speed a/d converter portfolio offers cost and performance optimized solutions for various applications such as communications infrastructure, electronic test and measurement, and aerospace and defense.
-
Product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
Switch Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20J
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2TB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
-
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1C1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Electronic AC Potential Standard
PMT25010
-
Power Measurement Technologies Inc.
Provides the electronic equivalent of a standard potential transformer as typically required for instrumentation potential transformer accuracy testing.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-C100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Automatic Voltage Regulating Relay- Standard Model
-
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I35-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-FK180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Coating thickness XRF Standards
-
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
Product
Standard Current Transformers
-
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.