product
LXI Microwave Multiplexer, 50Ω 6-Channel 13-Bank 18GHz SMA
60-801-213
The 60-801-213 is a 6-channel, 13-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
Cable Assembly, 160-Pin DIN41612, Male (With Female Screwlocks) To Female (With Male Screwlock), 3m
40-970-160-3m-MF
The cable assembly is suited for direct connection to Pickering Interfaces products using a Female DIN41612 connector. For applications in LXI products where 4 connectors are used in a horizontal row if the user requires all connectors to have a second fixing then the right hand connector can be fitted with the optional screwlock assembly 40-969-101.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 9-Bank 40GHz SMA-2.9
60-802-409
The 60-802-409 is a 4-channel, 9-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Microwave Multiplexer, SP6T, 1-Bank, 50GHz, 50Ω, SMA-2.4
60-800-601
Our 60-800-601 is a 1 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 8-Bank 40GHz SMA-2.9
60-802-408
The 60-802-408 is a 4-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
50 Ohm SMB to BNC Adaptor Assembly
40-978-501-0.5m
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
Power Supply, 30V, 50A, 1500W
N5765A
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight 1500W, single output N5765A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current. It delivers solid performance and a variety of basic and enhanced capabilities in a compact 1U package.
-
product
50 Ohm SMB to BNC Adaptor Assembly
40-978-501-1m
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 5-Bank 18GHz SMA
60-801-205
The 60-801-205 is a 6-channel, 5-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
Drive Controller Function Test – Universal Functional Test System for Industrial Electronics
General functional test system based on LXI instrumentation for high mix / low to medium volume manufacturing. DUTs are tested which are mainly used as communication and measurement modules in power plant technology, grid management and electrical drives.
-
product
LXI Microwave Multiplexer, SP4T, 3-Bank, 50GHz, 50Ω, SMA-2.4
60-803-603
Our 60-803-603 is a 3 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Reed Relay Matrix - Single 32x16 Plugin, No Direct Y Access, 3 Analog Buses
65-225-102
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 4-Bank 26.5GHz SMA
60-802-304
The 60-802-304 is a 4-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
75 Ohm Mini SMB to SMZ/Type 43 Adaptor Assembly
40-978-711-0.25m
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
75 Ohm 1.6/5.6 to 1.6/5.6 Cable Assembly
40-977-791-1m
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 9-Bank 26.5GHz SMA
60-801-309
The 60-801-309 is a 6-channel, 9-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Microwave Matrix, 20GHz, Single 3x3 With Loop-Thru
60-751-133-A
The 60-751-133-A is a single 3x3 20GHz microwave matrix with loop-thru. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection. It is available in a variety of configurations and frequencies up to 20GHz (60-751). The matrix is characterized for 50 ohm applications, for 75 ohm versions please consult your local sales representative.
-
product
LXI Microwave Matrix, 10GHz, Dual 3x3, Terminated With Loop-Thru
60-750-233-C
The 60-750-233-C is a dual 3x3 10GHz microwave matrix with internal termination and loop-thru. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection. It is available in a variety of configurations and frequencies up to 18GHz (60-751). The matrix is characterized for 50 ohm applications, for 75 ohm versions please consult your local sales representative.
-
product
LXI Optical Switching - 2x2 Matrix (Insert/Bypass) Plugin Module
65-280-360
The 65-280-360 2x2 matrix is part of the 65-280 and 65-281 ranges of optical plug-in modules offering matrix & insert/bypass or multiplexer & SPST topologies respectively with all models based on MEMS fiber optic switches and available in various populations per plugin. In addition, a choice of different connector styles to suit most applications is offered: FC/APC (for optimal performance), FC/PC, SC/PC and ST for general applications and LC for high density applications. They use MEMS (Micro-Electro-Mechanical-Systems) based optical switches to route signals between terminals by redirecting the optical signal. This is achieved using micromechanical mirrors driven by a highly precise mechanism activated via an electrical control signal.
-
product
LXI Reed Relay Matrix - Dual 32x16 Plugin, No Direct Y Access, 3 Analog Buses
65-225-101
These Modular LXI Matrix Reed Relay Matrix Modules plug into our LXI Modular Chassis (model 65-200-002)—providing access to all signal connection on 200 pin connectors. They are constructed using Pickering Electronics' Reed Relays offering maximum performance and reliability as well as very fast operate times.
-
product
LXI 8:1 Optical MUX SC Multi Mode
60-851-211
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
LXI And LXI/USB Modular Chassis
Our LXI modular chassis are available in 7 and 18-slot and our LXI/USB modular chassis are available in 2, 4 and 6-slot and support over 1,000 of our PXI modules. The PXI modules supported range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of simulation modules such as programmable resistors, digital I/O, power supplies, thermocouple simulators, function generator, battery simulators and attenuators. This gives you enormous flexibility to define a switching or T&M system to exactly match your needs.
-
product
LXI Microwave Multiplexer, SP6T, 7-Bank, 18GHz, 50Ω, SMA
60-800-107
Our 60-800-107 is a 7 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Reed Relay Matrix - Dual 64x8 Plugin, Direct Y Access, 6 Analog Buses
65-223-001
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
AXIe Products
The AXIe is an open standard, that leverages from existing standards from ATCA, PXI, LXI and IVI, with high performance per rack inch and added features including timing, triggering, and module-to-module data movement features that are important to the implementation of high-performance test and measurement systems.
-
product
Power Supply, 100V, 15A, 1500W
N5769A
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight 1500W, single output N5769A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current. It delivers solid performance and a variety of basic and enhanced capabilities in a compact 1U package.
-
product
LXI Microwave Multiplexer, SP4T, 3-Bank, 26.5GHz, 50Ω, SMA
Our 60-803-303 is a 3 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI High Voltage Switching - 50xSPST Plugin Module
65-233-900-HI
The 65-233-900-HI plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
LXI 1GHz 75ohm 8x8 Matrix
60-731-004
The 60-731 is a family of integrated RF matrices suitable for use up to 1.5GHz. The construction of the 60-731 provides a cost effective alternative for RF switching based on microwave switching elements while maintaining a high level of matrix performance. The design is fully scalable, allowing a variety of matrix sizes to be offered in a single family.
-
product
LXI Reed Relay Matrix - Single 128x4 Plugin, Direct Y Access, 12 Analog Buses
65-221-002
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.