Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Frequency Synthesizers
-
A frequency synthesizer allows the designer to generate a variety of output frequencies as multiples of a single reference frequency. The main application is in generating local oscillator (LO) signals for the up- and down-conversion of RF signals.
-
Product
Frequency Converter
-
Our frequency converters, which we offer with outputs of up to 500 kVA, can be used to supply alternating current consumers with constant voltages that deviate from the input network.
-
Product
Frequency Counter (225MHz - 18GHz)
S43180
-
S43180 series high-precision frequency counter is a high-precision frequency measurement instrument. It has a frequency measurement resolution of 10 bits per second. The whole machine scheme adopts countdown technology and digital interpolation technology to realize the high-precision measurement of the instrument. It has measurement functions such as frequency, period, frequency ratio and powerful mathematical statistics operations (maximum value, minimum value, average value, PPM, standard deviation, Allan variance).S43180 series has reliable performance, complete functions, high measurement accuracy, wide frequency measurement range, high sensitivity, large dynamic range, high cost performance and easy to use. It is especially suitable for frequency measurement in scientific research and measurement fields such as aerospace, crystal oscillators, and components.
-
Product
NF-Series Standard Plus Models
-
The E-DRIV® NF-Series standard plus models feature a selectable Double Hit Mode for soft joint applications and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Standard Capacitors
-
We offer a range of custom-designed standard capacitors to meet your High Voltage, Extra High Voltage and Ultra High Voltage requirements. Thanks to our polystyrene, air and SF6 gas capacitor technologies, we are able to meet the most demanding technical requirements in all industries.
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Turbidity And Standard Meters
-
Accurately measure the cloudiness of a fluid caused by suspended particles with turbidity meters and standards from HF scientific. Our turbidity meters and standards instruments include features that simplify installation, maintenance, and data access.We offer reliable turbidity meters including an online turbidity meter, handheld turbidity meter, and benchtop turbidity meter.
-
Product
Standards Waveform Generator
3110A
-
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
Product
Frequency Multipliers
-
Excellent suppression of undesired harmonics and spuriousLow multiplier lossRugged coaxial and surface mount packages
-
Product
Radio Frequency Probes HF77MATEAXm0112G540MSMPmP
1035527
-
The Radio Frequency Probes HF77MATEAXm0112G540MSMPmP is engineered for high precision and reliability in the realm of coaxial probing applications. With a pitch of 4.00 mm, this probe can operate effectively within a temperature range of -45°C to +100°C, ensuring versatility for various environments and conditions. Capable of handling continuous currents up to 0.50 A and operating at a frequency of 12.00 GHz, this model delivers exceptional performance for RF testing and measurement tasks.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Radio Frequency Probes (Automotive) HF860FAKRAm016G950MCXfS
1035672
-
The Radio Frequency Probes (Automotive) HF860FAKRAm016G950MCXfS are meticulously designed to meet the specific needs of automotive applications, making them a crucial tool for any professional in the field. Designed with a robust coaxial probe structure, these RF probes incorporate advanced materials such as beryllium copper and brass, ensuring exceptional durability and performance in various environmental conditions. They can operate effectively within a temperature range of -45°C to +100°C, making them suitable for both extreme temperatures and demanding applications.
-
Product
UL Standards Testing and Certification
-
If you are selling your product in the United States, your product must comply with the applicable nationally accepted UL standards. F2 Labs can evaluate and test your product, help you through the UL certification process and enable you to certify your product to the UL requirements through a Nationally Recognized Test Lab (NRTL).
-
Product
Absolute Contamination Standards (ACS)
-
The Absolute Contamination Standard (ACS) is used to calibrate instruments which size and detect particles on the surface of bare silicon wafers. Use ACS to characterize particles, before particles characterize products.
-
Product
High-Performance Radio Frequency Probe HF860FAKRAf016G930MCXfSV1
1037081
-
The HF860FAKRAf016G930MCXfSV1 is a high-performance Radio Frequency Probe designed specifically for automotive applications. This coaxial probe, with an order code of 1037081, delivers exceptional performance with its ability to handle temperatures ranging from -45°C to +100°C and accommodate a continuous current of up to 10A. At a compact pitch of 6.50mm (256mil), it is engineered for precision and durability, making it ideal for rigorous automotive testing environments.This probe features impressive electrical characteristics, including a 50-ohm impedance and a frequency range of up to 6GHz, ensuring reliable and efficient signal transmission. The mechanical specifications include a preload force of 450cN and maximum travel capabilities that increase operational flexibility. The tip and barrel of the probe are constructed with high-grade materials, such as beryllium copper and brass, plated with gold for enhanced durability, corrosion resistance, and conductivity. The HF860FAKRA's robust design is complemented by its standard plug connection type, ensuring easy integration into existing systems.
-
Product
Helmholtz Coils (Field Standards)
-
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
Product
Radio Frequency Probe HF77HFMf0212G1080MSMPmF
1114067
-
The HF77HFMf0212G1080MSMPmF Radio Frequency Probe is specifically designed for automotive applications, ensuring precise electromagnetic measurements. Its impressive operational temperature range, from -45°C to +100°C, makes it ideal for varied environmental conditions typically found in the automotive sector. Incorporating advanced coaxial design, this probe boasts a frequency capability of up to 12 GHz, and its 50-ohm impedance ensures optimal signal integrity.
-
Product
Radio Frequency Probe HF860PCBCO016G530MCXfSV1
1038951
-
The HF860PCBCO016G530MCXfSV1 is a high-performance Radio Frequency Probe designed for precision applications in the consumer electronics sector. With an impressive frequency range of up to 6 GHz and a robust impedance of 50 ohms, this probe ensures reliable signal integrity, suitable for a wide array of testing and measurement scenarios. It is engineered to perform in a temperature range of -45°C to +100°C, making it versatile enough for both indoor and outdoor applications.
-
Product
Neodymium Low Frequency Transducers
-
High energy neodymium magnetic designs, complex cooling systems and new technologies for high-power handling, minimal distortion and low weight.
-
Product
Audio Frequency Transmitter
TG 20/50
-
Cable fault location with the BAUR TG 20/50. The TG 20/50 is a portable, battery-operated audio generator with a built-in charging unit. Together with the UL audio frequency receiver and the SP detecting rod, the TG 20/50 is used for cable tracing, twist method and for determining the depth of cables and metal pipes.* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output* Two output frequencies selectable
-
Product
Radio Frequency Probe HF860PCBCO016G530MCXfSV2
1038941
-
The HF860PCBCO016G530MCXfSV2 Radio Frequency Probe represents an optimal choice for precision measurements in various applications, particularly in consumer electronics. With a robust design characterized by a coaxial probe configuration, it offers enhanced performance across multiple frequencies, specifically designed to meet the demands of high-frequency applications up to 6 GHz. This probe provides excellent connectivity thanks to its MCX female connection type, ensuring reliable interfacing with various RF components.
-
Product
Standard Digital Isolators
-
Analog Devices’ digital isolators enable designers to implement robust solutions with our magnetically isolated iCoupler products with the flexibility of up to 6 channels. Products meet stringent safety standards including the ability to isolate IS-IS with our intrinsically safe certified digital isolators which enable designs in hazardous areas. And automotive certified versions are also available. Utilizing the iCoupler® and isoPower® technologies, these isolation solutions enable designs without the constraints found in optocouplers.
-
Product
Coating thickness XRF Standards
-
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
Product
Standard Gain Horn Antenna
ZLB7-600-700-1846
-
Standard Gain Horn Antenna, Frequency0.6~1GHz, Gain10dBi, Power 200W, WR1150, Flange FDP8, Linear polarization, N type Female connector
-
Product
Radio Frequency Probes (Consumer) HF66SWH016G480MSMPmS
1024465
-
The Radio Frequency Probes HF66SWH016G480MSMPmS is an advanced coaxial probe designed for high-frequency applications. With a pitch of 5.00 mm and capable of operating within a temperature range of -45°C to +100°C, this probe ensures reliable performance in demanding environments. Its superior electrical specifications, including a continuous current rating of 0.50A and an impedance of 50 ohms at a frequency of up to 6 GHz, make it ideal for precise and efficient signal transmission.
-
Product
Standard Gain Horns
-
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas