Analog Output Modules
-
Product
PXIe-4464, 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-02
Analog Input Module
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 3 GHz, 50 Ω, N-Type, Failsafe
42-785C-561
Multiplexer Module
The 40-785C-561 (PXI) and 42-785C-561 (PXIe) are single failsafe SP6T 3 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
16GB DDR4-3200 1GbX8 1.2V ECC Samsung Chip
AQD-D4U16GE32-SE
Memory Module
16GB, Speed 3200MHz, 30u" Gold Plating Thickness, Anti-sulfurization resistance, ECC.
-
Product
PXI Dual SP4T MUX 26.5GHz 50Ω SMA
40-784-132
Multiplexer Module
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXIe Microwave Transfer Switch, Single, 26.5 GHz, 50 Ω, SMA, Failsafe
42-782B-531
Switch Module
The 40-782B-531 (PXI) and 42-782B-531 (PXIe) single failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 26.5 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
Thermocouple, Module, Receiver, 90 Series, 64 Position
510104133
Receiver Module
Primary mating module 510108124. (May mate with other ITA modules, as well.) *Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
Mini Coax, Module, Receiver, 90 Series, 37 Position
510104301
Receiver Module
Primary mating module 510108276.*Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
PXI Very High Density MUX 24 Chan 8 Pole
40-675-002-24/8
Multiplexer Module
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
PXI MUX 8 Banks of 8 Channel 2 Pole
40-610-022-8/8/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Multiplexer Single 64 Ch 1 Pole
40-630-022-64/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole and 1-pole screened.
-
Product
Signal Module, Receiver, QuadraPaddle, 192 Position, Right Angle Contacts For Custom PCB Mounting (510 150 130 And 510 109 315)
510150152
Receiver Module
This kit has everything you need to attach a VPC Receiver Module to a custom designed PCB. This includes the right angle header (P/N 510 109 315) and the Receiver Module (P/N 510 150 130).
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18GHz, 50Ω, SMA, Remote Mount
40-785C-421-E
Multiplexer Module
The 40-785C-421-E (PXI) and 42-785C-421-E (PXIe) are single SP4T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated, 3GHz, 50Ω, SMB
40-873A-001
Multiplexer Module
The 40-873A-001 (PXI) and 42-873A-001 (PXIe) are 4 to 1 RF MUX with 1 bank in a single slot. Additionally, extra switching allows unused channels to be terminated into 50 Ohm, maintaining signal integrity. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 50 GHz, 50 Ω, SMA-2.4, Terminated, Remote Mount, Failsafe
42-785C-451-TE
Multiplexer Module
The 40-785C-451-TE (PXI) and 42-785C-451-TE (PXIe) are single failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
SMARC Short Size Module with Intel® 6th Gen. Atom® x6000 Processors (formerly codename: Elkhart Lake)
LEC-EL
Computer on Module
The ADLINK LEC-EL is a SMARC module that supports Intel Atom® x6000 (x6425E, x6413E, x6211E, x6200FE, x6425RE) processors (formerly Elkhart Lake) with integrated Intel® UHD graphics and high speed interfaces. LEC-EL modules support up 8GB LPDDR4 memory, and are also available with rugged operating temperature range and low power envelope, making them a perfect match for mission critical fanless edge computing applications that require safety and reliability at all times.
-
Product
Coax, Module, ITA, 20/26 GHz/75 Ohm HD, 90 Series, 32 Position
510108179
ITA Module
Coax, Module, ITA, 20/26 GHz/75 Ohm HD, 90 Series, 32 PositionPrimary mating module 510104289.
-
Product
PXI Dual 6 Chan Mux 18GHz 50ohm SMA
40-785-522
Multiplexer Module
Pickering Interfaces PXI Microwave multiplexer modules are suitable for switching 50_ signals up to 40GHz. The 40-785 is available as a single or dual 6 channel multiplexer, with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Single 4 Ch Fiber Optic Multiplexer
40-810-014
Multiplexer Module
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or multi- mode fiber. A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
Product
LXI Microwave Multiplexer, SP4T, 6-Bank, 50GHz, 50Ω, SMA-2.4
60-803-606
Multiplexer Module
Our 60-803-606 is a 6 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI Remote Mount Triple SP6T Multiplexer 50GHz 50, SMA-2.4
40-785B-553-E
Multiplexer Module
The 40-785B-553-E is a remote mount triple 6-channel 50GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI 3A Power MUX BRIC, 6-Channel, 48-Pole
40-571-006
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe RF Multiplexer, Dual 8-Channel, 3GHz, 50Ω, SMB
40-874A-002
Multiplexer Module
The 40-874A-002 (PXI) and 42-874A-002 are 50 Ohm 8 to 1 RF multiplexers with 2 banks in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI 8-slot BRIC Multiplexer, 64-Channel, 10-Pole (6 Sub-cards)
40-570A-414
Multiplexer Module
The 40-570A-414 is a 64-channel, 10-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
MXM GPU Expansion Module
MIC-75GF10
Expansion Module
Support NVIDIA MXM GPU with whole system fanless designSupport up to 80W NVIDIA Quadro MXM 3.1 Type A/B form factor GPU1 x HDMI and 3 x DisplayPort 1.4a display outputOperating Temp. -10~50CSupport 1Grms Op. vibrationDual front removable 2.5" storage bay for easy swapIP40 fanless ruggedized compact size designMIC-7 Series compatible
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-785C-442
Multiplexer Module
The 40-785C-442 (PXI) and 42-785C-442 (PXIe) are dual failsafe SP4T 40 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-702-HI
Multiplexer Module
The 65-231-702-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 7 kV. Multiplexers are created by populating the 65-200-002 scalable chassis with multiplexer plug-in modules that provide access to the Channel and Common signals on 51-pin front panel connectors. Users can specify as many or as few plug-in modules as they require and can field upgrade the chassis to extend the multiplexer.
-
Product
PXI High Density MUX BRIC, 48-Chan, 20-Pole
40-570-316
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
LXI Microwave Multiplexer, 50Ω 36-Channel 1-Bank 4GHz BNC
60-891-001-002
Multiplexer Module
The multiplexer has an extremely high level of performance with low VSWR, very high isolation, low loss and high power handling. It is ideal for switching 50Ω systems for HF up to microwave frequencies. It occupies 2U of rack space, providing a compact switching solution.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 18GHz, 50Ω, SMA
60-800-105
Multiplexer Module
Our 60-800-105 is a 5 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.