Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
Product
PXIe-5450, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator
780419-01
Waveform Generator
PXIe, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator—The PXIe‑5450 is a 145 MHz, dual‐channel arbitrary waveform generator optimized for I/Q communications signals. It is an ideal instrument for testing devices with I/Q inputs, or as the baseband component of an RF vector signal generator. The PXIe‑5450 also features onboard signal processing (OSP) functions that include pulse shaping and interpolation filters, gain and offset control, and a numerically controlled oscillator (NCO) for frequency shifting. The PXIe‑5450 also features advanced synchronization and data streaming capabilities.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
40GHz Single Channel MW Signal Generator 19" 1U Rack
LSX4091R
Signal Generator
The LSX4091R is a 40GHz Single Channel Microwave Signal Generator, offers industry leading performance, in a 1U, 19” rack-mounted box. It features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The design offers excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
Product
PXI Vector Signal Analyzer
Vector Signal Analyzer
PXI Vector Signal Analyzers feature a wide frequency range, real-time signal analysis, and advanced signal processing. PXI Vector Signal Analyzers can perform measurements for a broad range of wireless technologies such as GSM, EDGE, WCDMA, LTE-Advance Pro, 5G, Wireless LAN, and Bluetooth. Select models also feature a LabVIEW-programmable FPGA that you can customize for advanced measurement applications. PXI Vector Signal Analyzers are ideal for microwave test, wireless test, RADAR test, spectral monitoring, software-defined radio (SDR), radio monitoring, interference detection, signal intelligence, and other applications.
-
Product
PXIe Precision AWG: 4 Channels, 400 MHz
M5301A
Arbitrary Waveform Generator
The M5301A is a single-slot PXIe module with four baseband AWG outputs, clock input and output, and four triggers. It provides high performance with easy-to-use programming libraries, real-time sequencing technology, and FPGA programming.
-
Product
PXIe-5667, PXI Vector Signal Analyzer
782366-01
Signal Module
Up to 7 GHz PXI Vector Signal Analyzer—The PXIe‑5667 is optimized for spectrum monitoring applications such as radio monitoring, interference detection, spectrum regulation, and related applications in line with ITU recommendations. It features real-time signal analysis and advanced signal processing using the capabilities of the built-in FPGA. The PXIe‑5667 includes options for various frequency ranges and instantaneous bandwidth.
-
Product
PCIe 16 Bit Arbitrary Waveform Generator - up to 125 MS/s on 4 Channels, up to 80 MS/s on 8 Channels
M2p.6568-x4
Arbitrary Waveform Generator
The M2p.65xx series offers different versions of arbitrary waveform generators for PCI Express with a maximum output rate of 125 MS/s. These boards allow to generate freely definable waveforms on several channels synchronously. With one of the synchronization options the setup of synchronous multi channel systems is possible as well as the combination of arbitrary waveform generator with digitizers of the M2p product family.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-V
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
PCI-5412, 100 MS/s, 14-Bit Waveform Generator Device
779177-03
Waveform Generator
The PCI‑5412 can generate user-defined, arbitrary waveforms and standard functions, including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms.
-
Product
LXI High Voltage Switching - 50xSPST Plugin Module
65-233-900
General Purpose Relay Module
The 65-233-900 plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 9 kV.
-
Product
PXIe-5663E, 6.6 GHz PXI Vector Signal Analyzer
781259-02
Signal Module
6.6 GHz PXI Vector Signal Analyzer - The PXIe‑5663E offers wide instantaneous bandwidth and supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. You can use a PXIe‑5663E as either a spectrum analyzer or vector signal analyzer, and you can use it with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5663E can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5663E provides a low-cost solution to high-performance RF measurements.The PXIe-5663E comprises the following modules:• PXIe-5601 RF Signal Downconverter• PXIe-5622 IF Digitizer• PXIe-5652 RF Analog Signal GeneratorThere is no physical device named "PXIe-5663E".
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Alternate 0.50 (14.00) - 2.50 (71.00) General Purpose Probe
P2662BG-1C2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Signal, Patchcord, Receiver, 36", TriPaddle, 22 AWG, Single Ended ( 5 Amps)
7-104922000-036
Signal Patchcord
Signal, Patchcord, Receiver, 36", TriPaddle, 22 AWG, Single Ended ( 5 Amps).
-
Product
Keysight 32-Channel FormC/Form A General Purpose Switch for 34980A
34937A
General Purpose Switch
The Keysight 34937A is a general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 28 independent single-pole, double-throw (SPDT) 1A relays and 4 single-pole, single-throw (Form A) 5A relays. This module is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The Form C channels are 300V, 1A contacts and can handle up to 60W, and the Form A channels are 30VDC/250VAC, 5A contacts and can handle up to 150W. Standard 50-pin Dsub connectors allow for use with standard cables, terminal blocks, or mass interconnect solutions.
-
Product
HPA-50 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-2W2S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Signal Patchcord, ITA, TriPaddle, 36", 16 AWG White, Single Ended, (10Amps)
7-101916000-036
Signal Patchcord
Signal Patchcord, ITA, TriPaddle, 36", 16 AWG White, Single Ended, (10Amps)
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Signal, Patchcord, ITA, 72", TriPaddle, 22 AWG White, Single Ended ( 5 Amps)
7-103922000-072
Signal Patchcord
Signal, Patchcord, ITA, 72", TriPaddle, 22 AWG White, Single Ended ( 5 Amps)
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
UXA Signal Analyzer, Multi-touch, 3 Hz to 110 GHz
N9041B
Signal Analyzer
Characterize challenging millimeter-wave signals: 5G, 802.11, satellite, radarMake continuous sweeps up to 110 GHzCapture lower-level spurious signals with DANL as low as -150 dBm/Hz (> 50 GHz)Simplify analysis of the latest wideband signals: 1 GHz fully-integrated instantaneous bandwidth; 5 GHz with external IF output
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1F-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
HPA-0 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Patchcord, Signal, Receiver, 72", QuadraPaddle Insert, Single Ended
7-152924000-072
Signal Patchcord
Patchcord, Signal, Receiver, 72", QuadraPaddle Insert, Single Ended
-
Product
CXA-m PXIe Signal Analyzer
M9290A
Signal Analyzer
Deploy a smaller microwave footprint, no trade-off in precision: Rely on fully specified performance up to 26.5 GHz in 4 slots Optimize your balance between speed, sensitivity and accuracy with the choice to operate in swept or FFT modes Perform fast calibrated stimulus response measurement with full-band tracking generator Smooth the transition between R&D, manufacturing, and maintenance: CXA-m is code compatible with benchtop X-Series signal analyzers and ESA spectrum analyzers
-
Product
Signal, Contact, ITA, TriPaddle, Round Post, PCB Mount
610110000
Signal Contact (ITA)
Primary mating contact 610110179. (May mate with other ITA contacts, as well.)
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Signal, Patchcord, Receiver, 72", TriPaddle, 24 AWG White, Single Ended ( 3 Amp)
7-104924000-072
Signal Patchcord
Signal, Patchcord, Receiver, 72", TriPaddle, 24 AWG White, Single Ended ( 3 Amp).





























