Boiler
closed vessel used to contain steam or fluids brought to high temperature.
-
Product
Boiler Auxiliaries Plant Control Simulator
MS 1300
-
BAPCON SIMULATOR is used to test and validate Boiler Auxiliaries Plant Control Unit (Sigma BAPCON). It has CAN interface for simulating inputs and it is a microprocessor based system.
-
Product
Combustion Efficiency Analyzer
CEA-100
-
Walsn CEA - 100 combustion efficiency analyzer is designed to continuously monitor CO content in flue gas while the measurement data can be used to adjust the ratio of fuel/ air so as to achieve the maximum boiler efficiency for boiler operation. Walsn CEA - 100 adopts the dual-measuring-sensor technology and features high accuracy with low zero drift and very small failure rate, matching the requirements of the harsh industrial environment. It is also easy to install and maintain.
-
Product
Gas Analysis
Si-CA 030
-
The Si-CA 030 offers everything heating engineers need to inspect and maintain residential and commercial boilers, with wireless connection to our smartphone app and automatic generation of servicing reports and certificates.
-
Product
Oxygen/Combustibles Analyzer
DT3006
-
The Datatest Model DT3006 Oxygen/CO analyzer is a microprocessor based instrument. It has a zirconia sensor for oxygen and an electrochemical sensor for carbon monoxide. Excellent trim control and boiler safety instrument with great reliability and stability thanks to the micro controller.
-
Product
Residential/Commercial Combustion Analyzer w/ NOx Sensor
C165+N
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Combustion Analyzers
-
The Seitron handheld analysers Chemist 100 and Novo are used worldwide for boiler fume analysis. All of our analysers are designed and manufactured in Italy to guarantee the highest quality and reliability.
-
Product
Furnace and Electrical Inspection Camera
FLIR GF309
-
The FLIR GF309 is designed for high temperature industrial furnace applications. These infrared cameras are ideal for monitoring all types of furnaces, heaters, and boilers, particularly in the chemical, petrochemical, and utility industries. Custom-built to see through flames, the FLIR GF309 also features a detachable heat shield designed to reflect heat away from the camera and camera operator, providing increased protection.
-
Product
Anemometers
-
Guangzhou Amittari Instruments Co.Ltd
Widely used in data collection for boiler, refrigeration industry, ventilation duct, environment monitor, navigation measurement, weather forecast, collection of the weather datum for outdoor busywork and fire department.
-
Product
Residential/Commercial Combustion Analyzer Kit w/ Pressure/Printer
C163KIT
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C163 Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to included printer and is wireless to a free printer App. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Air Humidity Meter
-
Since air humidity is an important factor in many sectors including but not limited to manufacturing, agriculture, construction, restoration, remediation and heating, ventilation and air conditioning (HVAC), PCE also carries a number of air humidity meter devices designed for specific applications such as evaluating heat stress risk in hot work environments like boiler rooms, factories, construction sites and commercial bakeries. To accurately assess heat stress risk, an air humidity meter capable of detecting and classifying temperature in relation to the amount of moisture content in the air is recommended. The global standard description for heat stress is the Wet Bulb Globe Temperature Index (WBGT).
-
Product
Combustion Analyzers
-
Test Products International, Inc.
Test gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.
-
Product
Frequency Conversion Rotating Magnetic Fla
MT-2XCF
-
MITECH MT-2XCF rechargeable frequency conversion rotating magnetic flaw detector is based on principle that the leakage magnetic field can absorb the magnetic powder. Make use of magnetic yoke magnetized the workpiece of ferromagnetic material. If there has defects it will produce leakage magnetic field that will adsorb magnetic powder. We could detect the flaw by observing the density of adsorption magnetic powder. It adopts large capacity lithium battery. By the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 6 hours. And the battery can be charged when the detector is on and off. Especially suitable for the field testing. It can choose the current frequency according to the flaw depth with unique frequency conversion communication design, that improve the detection sensitivity. It’s widely used in aircraft manufacturing, boiler and pressure vessels and other fields. It is a necessary professional precision instrument of quality control, in-service safety monitoring and life assessment.
-
Product
Combustion
-
Our combustion gas analysers are compatible with a wide range of machines, such as engines, industrial boilers, incinerators and industrial furnaces. They can be used to assess various combustion parameters, from efficiency and yield to CO, O, NOx and other gas concentrations in flue and exhaust gases.
-
Product
Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200M
-
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)
HD-480
-
The HD-480 industrial dissolved oxygen meter takes sequential measurements of the concentration of dissolved oxygen, which is an indicator used in the management of activated sludge tanks in waste water processing, and the quality of the water in boilers, or rivers and waterways.As there is no need to exchange the membrane of the disposable sensor included, it is easy for anyone to use.
-
Product
Portable Sulphuric Acid Dewpoint Temperature Monitor
-
The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.
-
Product
Commercial & Industrial
-
High-accuracy instruments for testing emissions, combustion efficiency, and safety in industrial boilers, furnaces, engines, and HVAC systems.
-
Product
Hopper Ash Level Thermocouple System
HALT
-
The Hopper Ash Level Thermocouple (HALT) System is a preventative maintenance and safety tool that continually monitors the levels of ash within a hopper. As the hopper plugs and the ash levels increase, the thermocouples will become insulated from the boiler heat by the ash. Low temperature readings trigger visual and digital alarms which indicate that the hopper has plugged.
-
Product
Combustion Efficiency Monitors
-
LAND has a range of gas analysers suitable for boiler combustion monitoring and control. The close monitoring of oxygen, carbon monoxide and the sulphuric acid dewpoint temperature can help improve combustion efficiency, reduce excess air, reduce energy losses and prevent plant corrosion due to sulphuric acid formation.
-
Product
Marine Emissions Analysers
Protea 2000
-
The Protea 2000 emissions monitoring system is approved for the analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2, CO2 and NOx.
-
Product
One Channel Gas Controller
Surveyor 4B
-
Teledyne Gas & Flame Detection
Teledyne Gas and Flame Detection has designed the SURVEYOR 4B as a monitoring apparatus specifically designed to ensure the safety of boiler plants, battery charging rooms or small units where your operations are at risk due to the possibility of flammable gas leaks.Developed for quick, safe detection, the SURVEYOR 4B control module combines highly reliable monitoring, simple implementation and low costs.
-
Product
Residential Combustion Analyzer
C161
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and now adds a heat exchanger test. Prints to optional printer. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Maple Syrup Refractometer
PA202X-304-305
-
The eMaple Digital Maple Syrup Refractometer can be used at the tree tap or tank to measure maple sap, for pre-process monitoring of reverse osmosis, in the sugar shack to determine when to draw maple syrup from the boiler, or during maple syrup bottling and testing. The eMaple Refractometer features two scales and measures from 0 to 85 Brix.
-
Product
Gas & Emissions Analyzer
Si-CA 8500
-
Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.
-
Product
Fixed Gas Detectors
OLCT 10 - OLC 10
-
Teledyne Gas & Flame Detection
The OLC 10 and OLCT 10 are designed to detect combustible or toxic gases for tertiary applications (boiler plants, battery charging rooms, car parks, hospitals). Two OLC 10's can be connected to one detection channel to monitor the same area, without an additional junction box or extra wiring. Similarly, up to five OLCT 10's can be connected to one channel for the detection of CO, NO or NO₂ in a car park application. Easy to install and operate, these detectors combined with the MX 16 control unit meet demanding user requirements.
-
Product
Hygrometers
-
A hygrometer is a device used to measure humidity. Many hygrometer products also measure temperature. A hygrometer that measures both humidity and temperature often is referred to as a thermo-hygrometer. PCE Instruments (PCE) offers a wide variety of hygrometer products used to measure the relative humidity of the air.Since humidity is an important factor in many sectors including but not limited to manufacturing, agriculture, construction, restoration, remediation and heating, ventilation and air conditioning (HVAC), PCE also carries a number of hygrometer devices designed for specific applications such as measuring the humidity in bales of pressed hay or in rolls of paper. A hygrometer also can be used to evaluate heat stress risk in hot work environments like boiler rooms, factories, construction sites and commercial bakeries. To accurately assess heat stress risk, a hygrometer capable of detecting and classifying temperature in relation to the amount of moisture content in the air is recommended. The global standard description for heat stress is the Wet Bulb Globe Temperature Index (WBGT). A combination hygrometer / thermometer, or thermo-hygrometer, can be used to verify the integrity of the cold chain during the transport and warehousing of refrigerated food and pharmaceutical products. This versatile and popular style of hygrometer also is ideal for evaluating the performance of HVAC systems in industrial, commercial and residential properties. If the humidity indoors is too high, mold can occur. Certain types of mold cause respiratory problems and other negative health effects for people living or working in the surrounding environment. In addition, mold that has permeated into the walls or roof of a structure must be removed for safety reasons. Mold remediation and removal, also called mold damage restoration, can be a costly endeavor, which is why preventative monitoring of the humidity indoors is preferable whenever possible.
-
Product
Stack Gas Analysis System
ENDA-5000 series
-
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
Product
High Quality UCI - And Leeb-measuring Technology
SONODUR Product Family
-
Foerster Instruments, Incorporated
The non-destructive UCI test method (Ultrasonic Contact Impedance) as well as the Leeb test method enable fast and mobile measurement as a supplement to the classical hardness test. Due to the compact measuring probes and sensors of the SONO series, the devices can also be used in difficult test positions and with complex component geometries. Fields of application are e.g. incoming goods inspection, mix-up testing, production control, quality assurance, weld seam testing, cut edge testing, maintenance on installed components as well as the replacement of dynamic hardness testers for small material thicknesses (below 50 mm, e.g. boilers, tubes).
-
Product
Sootblower Fouling Detection Systems
SFD
-
The Sootblower Fouling Detection (SFD) System is an ITM proprietary technology for measuring soot buildup along the path of a sootblower in recovery and utility boilers. Use this system to identify problematic areas and optimize sootblowing.
-
Product
Emission Testers
-
Maschinenbau Haldenwang GmbH & Co. KG.
A device that monitors the composition of the flue gas of a boiler heating unit to determine if the mixture of air and fuel is at the proper ratio for maximum heat output.