Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
Passive Probe, 10:1, 350 MHz, 1.3 M
N2872A
-
Compact 2.5-mm probe head diameter, low input capacitance, and various fine-pitch probe tip accessories make the Keysight N2870A Series passive probes ideal for probing densely populated IC components or surface-mount devices used in today’s high-speed digital applications.
-
Product
Other Passive Probes
-
Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.
-
Product
RGB/YUV Passive Video Switch
SWP4031
-
MicroImage Video Systems? Passive Video Switch line addresses the needs for basic and affordable video switching applications. Each switch is manufactured with a durable aluminum case. A rotary switch mounted on the front is used for selection.
-
Product
11-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB121
-
*Designed for PICMG 1.3 SBC*Compatible with AX61410, AX6145, AX6156 chassis*Supports one PICMG 1.3 CPU card slot, seven PCIe x4 slots, one PCIe x8 slot, and two 32bit/33MHz PCI slots
-
Product
6-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB210
-
*Designed for PICMG 1.3 SBC*Compatible with AX61222TP/AX61220TP chassis*Supports one PICMG 1.3 CPU card slot, two PCI slots, two PCIe x1 slots, and one PCIe x16 slot
-
Product
Passive Component Storage Module Series
TrayPXIe
-
The TrayPXIe is an accessory tray that stores your fragile passive fiber optic components such as splitters, connector adaptor patchcords, WDM couplers, and isolators in one handy module in the PXI chassis.
-
Product
Simulation Models for Passive Components, Transistors, Diodes, etc.
-
An indispensable collection of the industry''s most advanced simulation models for passive components, transistors, diodes and more. These reliable, measurement-based models maximize the RF/MW electronic design automation (EDA) process, reduce design cycle times, and lower product development cost. With a few EASY steps, the Modelithics Model Libraries are ready to use in EDA tools.
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Passive XMC-to-PCI Express Adapter
5944
-
The Technobox, Inc. P/N 5944 is designed to adapt a single-wide XMC card to a 16X PCI Express slot. The 5944 supports both P15 and P16 and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
13-slot ATX-supported PICMG Bus Passive Backplane
ATX6022/13L
-
*1 PICMG, 4 PCI and 8 ISA*Compatible with AX61400, AX6145, and AX6156LE*Supports both AT and ATX power supply
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
-
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Passive XMC-to-PCI Express Adapter
6065
-
The Technobox, Inc. P/N 6065 is designed to adapt a single-wide XMC card to a 8X PCI Express slot. The 6065 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
HDLC RS-232 / RS-422 / RS-485 Passive Tap Module – USB Port
VERSA-TAP™
-
Versa-Tap protocol analyzer offers a powerful hardware solution that features state-of-the art electronics and provides exceptional data-logging/analyzer capabilities at a fraction of the cost of the nearest competitor.
-
Product
Passive Probe, 10:1, 500 MHz, 1.3 M
N2873A
-
The N2873A passive probe offers DC to 500 MHz and 10:1 attenuation factor to address a wide range of measurement needs.
-
Product
5-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB205
-
The FAB205 features a PICMG 1.3 CPU card slot, five 32bit/33MHz PCI slots, and built in a 24-pin ATX power connector and 8-pin connector for thermal detected board. The FAB205 is optimized to support AXIOMTEK's PICMG 1.3 system host boards, the SHB100 and SHB110, which are built around the PICMG 1.3 form factor. The FAB205 is compatible with the AX61220/AX61222 chassis.
-
Product
Passive Wildlife Recorders - Acoustics & Bats
-
Now you can record bats, birds, frogs and other vocalising wildlife with one device. An easy-to-use recorder, compact, lightweight and customisable. It is designed to survive your tough field conditions. It is weatherproof and robust, with low-profile microphones (to reduce the likelihood of pesky livestock and wildlife chewing them).
-
Product
5-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB105-V1
-
*Designed for PICMG 1.3 SBC*Compatible with the AX61222TP/AX61220TP chassis*Supports one PICMG 1.3 CPU card slot, one PCIe x16 slot, and three 32bit/33MHz PCI slots
-
Product
Passive XMC-to-PCI Express Adapter
6066
-
Our Passive XMC-to-PCI Express Adapter +5VPWR 4X (6066) is designed to adapt a single-wide XMC card to a 4X PCI Express slot. The 6067 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card.
-
Product
Passive Probe, 10:1, 1.5 GHz, 1.3 M
N2874A
-
A compact 2.5-mm probe head diameter, low input capacitance, and fine-pitch probe tip accessories make the N2870A Series ideal for probing densely populated IC components or surface-mount devices used in today’s high-speed digital applications.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Passive Probe, 10:1/1:1, 350 MHz, 1.3m
N2889A
-
The Keysight N2889A low-cost passive probe provides up to 350 MHz bandwidth and features high-input resistance of 10 MΩ (@10:1 mode) to address a wide range of measurement needs with low probe loading. The N2889A comes with a convenient switch in the probe handle that lets you switch between a 1:1 and 10:1 attenuation ratio.
-
Product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
-
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
-
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
Passive Probe, 100:1, 1.5 GHz, 1.3 M
N2876A
-
The N2876A passive probe offers DC to 1.5 GHz and 100:1 attenuation factor to measure fast edges in high speed applications more accurately. This probe needs 50 Ω input on the oscilloscope.
-
Product
SP200B, 200 MHz, ±60 V, 1X or 10X Attenuation, Single-Ended Passive Oscilloscope Probe
780284-01
-
The SP200B is a standard switchable passive probe for oscilloscopes that provide 1 MΩ input impedance. Depending on the attenuation ratio, the probe has an analog bandwidth of 6 MHz in the 1x attenuation setting or 200 MHz in the 10x attenuation setting.
-
Product
ABex Passive Terminal Module for Meilhaus ME-9000
ABex TM-ME-9000
-
The ABex TM-ME-9000 is an ABex terminal module for the ABex system to route signals from a Meilhaus ME-9000 device to the front connector of the ABex. It is only a feedthrough-module.
-
Product
GPS, GLONASS, Galileo Splitter 8 Way, TNC, 1000 - 2000 MHz, 50 Ohm, Passive
GPS820
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy TNC Female (Jack) 50 Ohm





























